1. Catalogs
  2. Instrument Systems
  3. CAS 120 Array spectrometer for lab and production

CAS 120 Array spectrometer for lab and production

CAS 120 Array spectrometer for lab and production

CAS 120 Array spectrometer for lab and production

Product catalog summary
Key Features:
  • The device includes a precision spectrograph with an integrated density filter wheel (OD 1-4) and automatic dark current correction.
  • It is equipped with a 2048 x 14 pixels back-illuminated CCD detector, featuring a 16-bit ADC and short integration times of 4 ms.
  • Offers a USB interface and hardware I/O trigger for precise timing and synchronization.
Applications:

The CAS 120 is tailored for production environments, especially in LED production testing and quality assurance, providing high reliability and speed at reduced costs, suitable for continuous 24/7 operation.

Equipment and Functionality:
  • Incorporates a Crossed Czerny-Turner spectrograph with an integrated density filter wheel and dark current shutter for optimal optical precision.
  • The back-thinned CCD detector enhances measuring sensitivity and dynamic range.
  • Features a filter wheel with an electronic angle sensor for reliable filter position identification and expanded dynamic range.
Software and Measurement:
  • Comes with DLL and LabVIEW® driver for seamless integration in production environments.
  • Includes SpecWin Pro and SpecWin Light software packages for detailed spectral analysis and documentation.
  • Capable of measuring luminous flux, color coordinates, color rendering index, and various wavelength parameters in a single measurement.
Technical Specifications:
  • Available in UV/VIS (200-800 nm) and VIS (360-830 nm) models.
  • Features a 16-bit AD converter, USB 2.0 interface, and a dynamic range of 14000:1.
  • Ensures measurement accuracy and reproducibility with factory calibration and ISO 17025 accreditation.
Ordering Information:
  • Offers various models and accessories, including measurement adapters for production and laboratory applications.
  • Provides calibration services for radiant intensity, luminous intensity, and luminous flux.
  • Software options include SpecWin Light, SpecWin Pro, and a software development kit.
See more

Catalog excerpts

CAS 120 Array spectrometer for lab and production-1

CAS 120 Array spectrometer for lab and production We bring quality to light.

 Open the catalog to page 1
CAS 120 Array spectrometer for lab and production-2

Key features at a glance y Precision spectrograph with integrated density filter wheel (OD 1-4) y Shutter for automatic dark current correction y 2048 x 14 pixels back-illuminated CCD d etector, 16 bit ADC y Short integration times of 4 ms y USB interface y Hardware I/O trigger 01 \\ AS 120 – The powerful spectrometer, C specialized for production The high-performance CAS 120 makes it more feasible to deploy the proven metrology from Instrument Systems even in pricesensitive applications, such as LED production testing or quality assurance. alongside reduced cost even under the demanding conditions...

 Open the catalog to page 2
CAS 120 Array spectrometer for lab and production-3

02 \\ Equipment and mode of functioning Optical setup with CCT spectrograph A Crossed Czerny-Turner spectograph with integrated density filter wheel and dark current shutter forms the core of the CAS 120. It guarantees maximum optical precision with exceptionally good straylight rejection and a high level of optical precision. ~ Optical setup of the CAS 120 with optimized Crossed Czerny-Turner spectograph. Back-illuminated CCD detector A back-thinned CCD area sensor with 2048 x 14 pixels is used in the CAS 120. This sensor offers a high level of measuring sensitivity and large dynamic range....

 Open the catalog to page 3
CAS 120 Array spectrometer for lab and production-4

Software package / LED Measurement 03 \\ Versatile software package Instrument Systems supplies a DLL and a LabVIEW® driver for use in production environments and at automated measurement stations. Calculation of all photometric, radiometric and colorimetric quantities is included in the software packages. This permits fast and easy integration within existing production facilities. SpecWin Pro and SpecWin Light SpecWin Pro and SpecWin Light spectral software packages have been developed for a wide range of interactive semi-automatic and even fully automatic laboratory applications. Each package...

 Open the catalog to page 4
CAS 120 Array spectrometer for lab and production-5

LED Measurement / Test laboratories / Service and support Measurement of luminous intensity ~ Adapter and test socket for averaged LED intensity measurements. The measurement adapters of the LED 4xx series permit luminous intensity measurements in conformity with CIE standards to be carried out in the laboratory and in the backend-of-line processes. Instrument Systems has developed the EKT-10x Measurement of luminous flux ISP 150L Integrating Sphere for production applications. The integrating spheres with a proven track record from Instrument Systems are used for taking precise measurements...

 Open the catalog to page 5
CAS 120 Array spectrometer for lab and production-6

Technical specifications 07 \\ echnical specifications T Model Spectral range Number of pixels (vertically binned) Datapoint interval Integration time Dynamic range Straylight Broadband for Illuminant A radiation 4) Measuring range luminous intensity 6) Measuring range luminous flux 7) Measurement uncertainty luminous intensity 8) Measurement uncertainty luminous flux 8) Measurement uncertainty dominant wavelength 8) Measurement uncertainty color coordinates 8) Spectroradiometry Sensitivity range for irradiance 9) Signal sensitivity at 1 s integration time Spectroradiometric accuracy Measurement...

 Open the catalog to page 6
CAS 120 Array spectrometer for lab and production-7

08 \\ rdering information O Order number Model VIS; 360 to 830 nm; 2048 pixels back-illuminated CCD detector; 2.2 nm spectral resolution (100 μm slit) Model UV-VIS; 200 to 800 nm; 2048 pixels back-illuminated CCD detector; 2.7 nm spectral resolution (100 μm slit) 50 μm slit (instead of standard 100 μm slit) Measurement adapters for production applications LED-433-16 Luminous intensity measurement adapter for LEDs; ILED-B (0.01 sr); incl. OFG-414 and PLG-411; 380 to 1600 nm; shortened version Luminous intensity measurement adapter for LEDs; ILED-B (0.01 sr); incl. OFG-424 and PLG-421; 190 to 1350...

 Open the catalog to page 7
CAS 120 Array spectrometer for lab and production-8

We bring quality to light.

 Open the catalog to page 8

All Instrument Systems catalogs and technical brochures

  1. VTC 2400

    2  Pages

  2. CAS 125-HR

    2  Pages

  3. Photometers

    24  Pages

  4. LEDGON 100

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.