ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR
12Pages

{{requestButtons}}

Catalog excerpts

ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 1

Instrument Systems KONICA MINOLTA Group ACS & ACU Series Advanced Calibration Standards White, RGB, UV and IR

Open the catalog to page 1
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 2

Key features at a glance A Advanced Calibration Standards on LED basis available in white, RGB, UV and IR A Reference values for radiant or luminous flux, averaged LED intensity and luminance traceable to PTB standards (in conformity with DIN ISO 17025) A Specification of color coordinates and dominant wavelength or color temperature if applicable A 0.2 % photometric stability over min. 100 operating hours for ACS standards with white LED A Maximum operational reliability by use with an ACU control unit The LED calibration standards of the ACS series allow you an easy and reliable accuracy...

Open the catalog to page 2
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 3

ACS-570-x – LED calibration standards for luminous flux and luminous intensity 100 Red LED Spectral radiant power / /% Spectral radiant power % The ACS 570 LED calibration standards for luminous flux and averaged LED intensity ILED-B are available in cool white (ACS-570-1) and the three basic colors blue (-3), green (-5) and red (-7). This covers the entire visible spectral range. Normally, the white ACS-570-1 is used for the calibration of all larger integrating spheres ISP and luminous intensity adapters LED-4xx from Instrument systems. Typical luminous flux values are 20 - 30 lm and the...

Open the catalog to page 3
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 4

ACS-570-2x – UV LED calibration standards for radiant flux The ACS 570 UV LED calibration standards from Instrument Systems are available in three versions with typical peak wavelengths 280 nm for UVC (ACS-570-24), 305 nm for UVB (ACS-570-26), and 365 nm for UVA (ACS-570-28). The extremely low measurement uncertainties (k = 2) of only 4.5% in UVC, 3.5% in UVB and 2% in UVA are comparatively low as in the visible range, which is metrologically less challenging. UV-LED calibration standards can be used for monitoring and for the absolute calibration of special UV measurement equipment such as...

Open the catalog to page 4
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 5

ACS 586/587 – LED luminance standards The ACS 586/587 are new, highly stable LED luminance standards. They support testing of all luminance meters on both filter and spectroradiometric basis. The radiation of the high-power LED is emitted into an integrating sphere with an inner diameter of 100 mm through a diffuser. The inner layer of the integrating sphere homogenizes further the radiation and emits homogeneous luminance through an opening of 25 mm in diameter. This structure ensures that the LED luminance standard has Lambertian radiation characteristics. The reference values, the...

Open the catalog to page 5
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 6

ACU The ACU is a new compact control unit for ACS calibration standards from Instrument Systems. It contains a high-precision constant current source in a compact desktop housing in addition to a TEC controller for accurate temperature stabilization. The ACU has been developed for both laboratory and production use. The ACU is controlled by means of a computer via USB using the ACS-Control software. Both, Windows 10 and OS X operating systems are supported. Moreover, the relevant program libraries (.dll and .dylib) are available for direct access for both operating systems Windows and OS X....

Open the catalog to page 6
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 7

After completion of the short stabilization phase, the forward voltage and the temperature remain constant. The radiant power of the LED therefore remains constant over a long service life and the fast operational readiness saves valuable time. ACS 570 in application ACS 570 can be applied to monitor various systems. For luminous flux measurements with ACS 570 there are adapters available for all spheres manufactured by Instrument Systems. The adapters are universally applicable with all our LED test sockets. For averaged LED intensity measurements, the ACS 570 can be connected directly to...

Open the catalog to page 7
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 9

1 Exact value determined with DTS 140 with following uncertainties: luminance: ±3.5%; color coordinates: ±0.0015; CCT ±10K 2) Determined with LumiTop 2700, distance 50 cm, FOV 15 mm, max. translation from center ±10 mm

Open the catalog to page 9
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 10

1 Exact value determined with DTS 140 with following uncertainties: luminance: ±3.5%; chromaticity coordinates: ±0.0015; CCT: ±10 K 2) The response non uniformity (RNU) is calculated for an image with 16 pixels cropped at each edge and 10 by 10 pixel binning (34 averages). The RNU is defined as the 95% percentile of the deviation of all bins from the mean image value. 3) Within central 63% of the light emitting aperture, i.e. 32 mm in diameter (lateral positioning accuracy: ±2 mm from center; tilt tolerance: ±0.5° from perpendicular). Please note: Audit limits for usage of ACS in production...

Open the catalog to page 10
ACS&ACU - Advanced Calibration Standards White, RGB, UV and IR - 12

We bring quality to light.

Open the catalog to page 12