1. Catalogs
  2. Instrument Systems
  3. 2D imaging colorimeter with manual objective lenses - LumiCam Series

2D imaging colorimeter with manual objective lenses - LumiCam Series

2D imaging colorimeter with manual objective lenses - LumiCam Series
1 / 16 PagesView full catalog

2D imaging colorimeter with manual objective lenses - LumiCam Series

Product catalog summary
Key Features:
  • Available in Mono, Color, and Advanced variants.
  • High-resolution sensor up to five megapixels.
  • Wide luminance measuring range up to 13 orders of magnitude.
  • Dynamic range of five decades in a single image.
Functioning Principle:

The LumiCam is a high-resolution 2D luminance and color measurement device using optical filters. It generates a 2D image of photometric data by assigning calibrated luminance and color values to each pixel. Data exchange is facilitated via a network cable, with filter wheel control via USB.

LumiCam Variants and Sensor Resolution:
  • LumiCam Mono: Compact design with a Y' filter for precise luminance measurement.
  • LumiCam Color: Equipped with a filter wheel for detailed color analysis.
  • LumiCam Advanced: Features six color filters and a matrix optimization algorithm for narrow-band light sources.

Sensor resolutions are 1370 x 1020 pixels for LumiCam 1300 and 2428 x 2028 pixels for LumiCam 2400.

Powerful and Fast Analysis Software:

The software supports photometric data analysis with tools like spotmeter, line profiles, and 3D objects. It calculates quantities such as luminance distribution, color coordinates, and contrast, with results displayed in various color schemes. Export options include ASCII and PDF formats.

Advanced Software Packages:
  • Black Mura Audit: Evaluates luminance uniformity in LC displays under black screen conditions.
  • Standardized Data Evaluation: Ensures compliance with international standards, crucial for automotive industry requirements.
Flexible Hardware Options:

Includes lenses with focal lengths from 28 mm to 100 mm, calibrated neutral density filters, and external apertures. The DTS 400 system allows precise positioning of the device under test.

Innovative Measurement Solutions:
  • LVK Analysis Kit: Measures luminous intensity distribution curves and spatial homogeneity of color coordinates.
  • BSDF Analysis Kit: Analyzes scattered light for reflection and transmission distribution functions.
Accredited Quality and Service:

Instrument Systems ensures reliable and traceable measurement results, accredited according to DIN EN ISO/IEC 17025. Services include engineering support, re-calibration, and software updates.

Technical Specifications:

Details on photometric and colorimetric quantities, sensor specifications, and measurement accuracy are provided for each LumiCam variant.

Technical Specifications
  • Accuracy and Repeatability: The document specifies accuracy and repeatability for LED color light, dominant wavelength, and color coordinates. For example, accuracy for LED color light is ±0.005, and repeatability for dominant wavelength is ±0.05 nm.
  • Filter Match: The filter match specifications are provided for different color channels, with values such as f1' (Y) < 3% and f1' (Xb) < 6%.
  • General Specifications: The interface options include Gigabit Ethernet and USB 1.0/2.0. The operating systems supported are Windows 7 and Windows 10. Dimensions and weight vary between models, with power supplied externally at 12 V.
  • Environmental Conditions: Operating conditions are specified between 10 to 40 °C with a maximum of 75% relative humidity.
Camera Data
  • Photometric and Colorimetric Quantities: The document lists quantities such as luminance, luminous intensity, color coordinates, and dominant wavelength.
  • Camera Specifications: Effective pixels are 1370 x 1020, with a pixel size of 6.45 µm x 6.45 µm. The AD converter is 12 bit, and the CCD sensor size is 2/3''.
  • Measurement Range: The dynamic range for single exposure is 4,600:1, and for multiple exposure mode, it is 6,000,000:1. The measurement range extends from 0.1 mcd/m² to 100,000 cd/m².
Ordering Information
  • LumiCam Variants: Different models such as LumiCam 2400 Mono, Color, and Advanced are available, each with specific pixel configurations and interfaces.
  • Lenses and Accessories: Various lenses and accessories are listed, including objective lenses and neutral density filters.
  • Software and Other Equipment: Software options like the Black Mura Plug-in and additional equipment such as optical benches and carriers for measurement setups are available.
Contact Information

Instrument Systems GmbH, located in Munich, Germany, provides contact details for further inquiries.

See more

Catalog excerpts

2D imaging colorimeter with manual objective lenses - LumiCam Series-1

Instrument Systems KONICA MINOLTA Group 2D imaging colorimeter with manual objective lenses

 Open the catalog to page 1
2D imaging colorimeter with manual objective lenses - LumiCam Series-2

Key features at a glance y LumiCam variants Mono, Color, and Advanced y High-resolution sensor up to five megapixels y Wide luminance measuring range – up to 13 orders of magnitude y Multiple exposures allow a dynamic range of five decades in a single image 01 \\ umiCam – imaging colorimeter for L advanced 2D light measurement The key to a precise light measurement is foremost research, quality and consistency. With this in mind all products developed at Instrument Systems provide most advanced light analysis solutions in order to accomplish complex measurement requirements in aviation, automotive,...

 Open the catalog to page 2
2D imaging colorimeter with manual objective lenses - LumiCam Series-3

► Functioning principle / LumiCam variants and sensor resolution ► Functioning principle / LumiCam variants and sensor resolution The LumiCam is a high-resolution 2D luminance and color measurement device based on optical filters. Dependent on the LumiCam variant a sensor-adjusted filter is either permanently mounted between the lens and the sensor or a filter wheel allows for a successive pivoting of multiple individual filters into the detection path. Each pixel of the camera sensor is assigned a calibrated luminance and color value to generate a 2D image of the photometric data. The data exchange...

 Open the catalog to page 3
2D imaging colorimeter with manual objective lenses - LumiCam Series-4

► LumiCam variants and sensor resolution ► LumiCam variants and sensor resolution LumiCam Color The LumiCam Color is equipped with a positioning wheel holding the four color filters X1', X2', Y' and Z', jointly resembling the tristimulus functions of the eye receptors. Thus, the camera gives access to a detailed analysis of the color coordinates (x, y and u', v'), correlated color temperature, dominant wavelength as well as color purity. LumiCam Advanced The LumiCam Advanced features six color filters (X1', X2', Y', Z' plus two correction filters K', L') and a patented matrix optimization algorithm...

 Open the catalog to page 4
2D imaging colorimeter with manual objective lenses - LumiCam Series-5

► Powerful and fast analysis software The LumiCam is supported with powerful diagnostic software for the investigation of photometric data. The large and continuously growing collection of graphical software analysis tools includes y Spotmeter of variable sizes y Line profiles and polylines generated by individually set anchor points y Polygons for flexible bounding areas y 3D objects These features provide the user a straightforward and flexible way to define regions of interest within a captured image, where the 3D box permits a clear and detailed data visualization in false color scheme. Based...

 Open the catalog to page 5
2D imaging colorimeter with manual objective lenses - LumiCam Series-6

► Advanced software packages Black Mura audit The Japanese expression ‘Mura' addresses unwanted local luminance and/or color variations within a liquid crystal (LC) display where Black Mura stands for Mura effects at black screen condition. The quantification of Black Mura effects in LC displays is of particular importance as the human eye at dark conditions has highest contrast sensitivity (Weber-Fechner law). In combination with the fact that LCs are embedded in a black mask within a black display frame, the task to determine the luminance uniformity under black screen condition is essential...

 Open the catalog to page 6
2D imaging colorimeter with manual objective lenses - LumiCam Series-7

► Flexible hardware options Optical accessories: Density filters, lenses & external apertures External optical equipment for the LumiCam includes calibrated neutral density filters such as OD2 or OD4. In combination with internal or external apertures they account for a dynamic measurement range of up to 13 orders of magnitude. Magnetic mounts ensure an easy and reproducible installation of the provided external apertures and density filters while the set of lenses with focal lengths from 28 mm to 100 mm covers a wide range of viewing directions. ◄ Have a closer look: Magnetic mounts ensure an...

 Open the catalog to page 7
2D imaging colorimeter with manual objective lenses - LumiCam Series-8

Flexible hardware options / Innovative measurement solutions Manual positioning system DTS 400 The manual positioning system DTS 400 permits an exact positioning of the device under test with respect to the LumiCam for all three spatial dimensions. This can be of special interest when it comes to the observation of instrument clusters, where an accurate repositioning of the camera is required. ~ The DTS 400 permits a precise positioning of the LumiCam at far distance from the device under test. 07 \\ Innovative measurement solutions LVK analysis kit Instrument Systems provides a turnkey analysis...

 Open the catalog to page 8
2D imaging colorimeter with manual objective lenses - LumiCam Series-9

► Innovative measurement solutions ► Innovative measurement solutions BSDF analysis kit Instrument Systems offers an advanced and straightforward BSDF (bidirectional scattering distribution function) analysis kit for a precise directional analysis of scattered light. The BSDF setup is comprised of an isotropic point light source with stabilized power supply and an optical bench holding the sample as well as the LumiCam. The component lineup can be chosen to measure either the bidirectional reflection distribution function (BRDF) or to determine the bidirectional transmission distribution function...

 Open the catalog to page 9
2D imaging colorimeter with manual objective lenses - LumiCam Series-10

► Accredited quality / Service and support As a leading manufacturer of light measurement equipment Instrument Systems strives to ensure that you can put greatest possible trust in our instruments. Thanks to the accreditation of our test laboratories according to DIN EN ISO/IEC 17025, our customers enjoy reliable and traceable measurement results and guaranteed comparability between different measurement instruments. This enables our customers to demonstrate the quality of measurements to any third party and ensures excellent accountability. Besides the DIN EN 13032-1 test procedure for photometric...

 Open the catalog to page 10
2D imaging colorimeter with manual objective lenses - LumiCam Series-12

Instrument Systems continuously endeavours to develop and improve its products. Any technical changes, errors or misprints do not form ground for compensation. The company’s terms of delivery and payment apply in all other respects. If not otherwise stated explicitly, all specifications refer to the Nikon 50 mm lens with a 16 mm aperture. 11 For external apertures (diameter 4 mm, 8 mm, 16 mm, 32 mm) with effective f-numbers 14 (4 mm) - 1.4 (32 mm). 2) The lower limit corresponds to the maximal exposure time and smallest f-number at SNR 10:1 and vice versa. 4) Specification of LumiCam 2400 Advanced...

 Open the catalog to page 12