2530 Series High Force Static Load Cells
2Pages

{{requestButtons}}

Catalog excerpts

2530 Series High Force Static Load Cells - 1

2530 SERIES STATIC LOAD CELLS 500 N - 300 kN Instron® load cells are a key part of a materials testing system. Among our competitors, Instron is the only global materials testing supplier that designs and manufactures its own load cells. This ensures that Instron load cells meet the unique requirements of materials testing such as; high accuracy over a wide measurement range, high stiffness, resistance to offset loads, accurate alignment and excellent zero stability. The 2530-xxxN Series load cells are specifically designed for use with 3400 and 3300 testing systems. The design, manufacture, and performance verification is conducted with materials testing applications in mind. Automatic transducer recognition and electrical calibration makes them easy to use. The load cells incorporate overload protection and can withstand loads up to 150% of their force capacity reducing the possibility of damage and 300% without mechanical failure. The load cells allow the user to zero out the tare weight of a grip or fixture that weighs up to 10% of the force capacity, while still maintaining the full accuracy. All Instron load cells are individually temperature compensated and tested for accuracy and repeatability on calibration apparatus that is traceable to international standards, with a measurement uncertainty that does not exceed one third of the permissible error of the load cell. Instron 2530-xxxN series load cells are precision force transducers consisting of a full strain gauge bridge bonded to a stiff and highly linear elastic element. When the element is subjected to a force, the electrical resistance of the gauges changes, providing an output signal proportional to the applied force. • Force capacities from ±500 N - ±300 kN (50 – 30,000 kgf, 112 – 67,500 lbf) • Suitable for a range of test types, including tension, compression, cyclic, and reverse stress • Accurate measurements down to 1/500th of load cell capacity- means fewer load cells and fewer load cell changes • Automatic recognition with electronic serial number and electrical calibration allows for means simple,error-free operation • 150% of force capacity overload capability – reduces the possibility of damage • Tare weight 10% of Force Capacity – can be used with a wide range of grips and fixtures • Can be used with optional Quick Change and Piggy Back Adapters to facilitate a quick change over of load cells • Precision machining and construction along with high axial and lateral stiffness helps to maintain system alignment • Low sensitivity to offset loads improves consistency of results • Complies with all international force measurement standards, including ASTM E4, ISO 7500-1 class 0.5, and JIS B7721, B7733 The load cells are designed to operate in tension, compression, cyclic and reverse stress. They have a wide measurement range allowing accurate force measurements to be made down to 1/500th of the load cells capacity, reducing the ne

Open the catalog to page 1
2530 Series High Force Static Load Cells - 2

2530 SERIES STATIC LOAD CELLS 500 N - 300 kN SPECIFICATIONS Catalog Number Force Capacity Mechanical Fitting (Load String) Effective Length Mechanical Fitting Off-Center Loading Error GENERAL PERFORMANCE Linearity ±0.25% of Reading from 0.2 to 100% of Force Capacity 0.25% of Reading from 0.2 to 100% of Force Capacity ±0.1% of Force Capacity (difference between increasing and decreasing force measurements at 50% of capacity) ±0.1% of Force Capacity (3 minutes after application of full force) Maximum Tare Weight 150% of Force Capacity without Calibration Change, 300% of Force Capacity without...

Open the catalog to page 2

All Instron catalogs and technical brochures

  1. HDX Models

    2 Pages

  2. DX MODELS

    4 Pages

  3. ElectroPuls™

    10 Pages

Archived catalogs