PEL-3000E Series Programmable D.C. Electronic Load GUj IflSTEK Simply Reliable • 1-150V(PEL-3031E)Min. Operating Voltage(dc) : IV at 60A, 0.5V at 30A 2.5-500V(PEL-3032E)Min. Operating Voltage(dc) : 2.5V at 15A, 1.25V at 7.5A • 7 Operating Modes : CC, CV, CR, CP, CC+CV, CR+CV, CP+CV • Fast/Normal Sequence Function • Soft Start • Battery Discharge Test • OCP, OPP Test Automation • Max. Slew Rate : 2.5A/ ps • Dynamic Mode • Protection : OVP, OCP, OPP, OTP, RVP, UVP • Remote Sense • Integrate Voltage, Current and Power Measurement Functions • External Voltage or Resistance Control • Rear Panel BNC, Trigger IN/OUT • Analog External Control • USB/GPIB(Option

Open the catalog to page 1
The PEL-3000E brochure - 2

GW Instek launches new PEL-3000E series programmable single-channel electronic load. In the series, PEL-3031E provides 300W (1V~150V/60A) and PEL-3032E provides 300W(2.5V~500V/15A) current sink capability. Inherited from the PEL-3000 series, PEL-3000E has an easy-to-read LCD panel and user-friendly interface. This model features high speed and accurate measurement capability for electronic component, battery, portable charger and power products that require low to medium power consumption. The PEL-3000E series is designed for current sink operation starting from 60mA and aims at measurement...

Open the catalog to page 2
The PEL-3000E brochure - 3

The PEL-3000E series provides four fundamental operating modes and three add-on modes of CC, CR and CP separately combining with CV. Users can set different load condition under different operating modes such as setting operating range for load level, Current Slew Rate, input voltage and load current. The input voltage range has two levels - high and low. The load current operating range has two levels - high and low current levels which possess different resolution to meet test requirements of different power product specifications. CC Mode Under constant current mode, electronic load will...

Open the catalog to page 3
The PEL-3000E brochure - 4

FAST SEQUENCE & NORMAL SEQUENCE Fast Sequence Diagram Normal Sequence Diagram Simulating Load Current Set a complete sequence editing function to Fulfilling Production Test Measurement Load Current obtain following waveforms. Users can save development cost and time without using a PC to control electronic load and writing programs. Power-driven Tools Simulation Test When operating the Sequence Function, PEL-3000E Series Ramp function of PEL-3000E Series is able to set the current follows the time and load settings of step1, step2, step3, etc. transition. When turned on, the current takes...

Open the catalog to page 4
The PEL-3000E brochure - 5

BATT TEST AUTOMATION CP Mode Data Edit for Battery Discharge SlewRate J 625.0 mA/us I BATT Test Automation Editing The built-in BATT Test Automation of PEL-3000E provides battery discharge applications with more flexible discharge stop time setting as well as rise and fall Slew Rate for discharge current settings. Under CP, CC or CR mode, the conditions for stop discharge can be set respectively. For instance, set the input voltage for stop discharge current, the execution time for discharge current or total discharge current*time (AH) to satisfy the verification of battery...

Open the catalog to page 5
The PEL-3000E brochure - 6

TRIGGER IN/OUT BNC Trigger In/Out function could be turned on or off by CONFIGURE setting of PEL-3000E. The Trigger Input can be set the delay time while the Trigger Out Pulse Width can be set as well. The trigger output signal is generated every time a switching operation is performed such as Dynamic mode or Fast/Normal sequence is executed when the trig out parameter is enabled. The trigger output signal from TRIG OUT BNC is a 4.5V pulse of at least 2us with an impedance of 500ohm. The common potential is connected to the chassis potential. The signal threshold level is TTL. The TRIG IN...

Open the catalog to page 6
The PEL-3000E brochure - 7

PANEL INTRODUCTION 2. Short 3. Load On/Off 4. Scroll wheel 5. USB 6. Sense +/7. Input terminals 8. LCD Display 9. Function keys 10. Analog control ports 11. Triggr out port 12. Trigger in port 13. Power socket VON VOLTAGE AND VON LATCH FUNCTION Von Latch = OFF Von Voltage is the threshold voltage for electronic load to activate or terminate sinking current. When Von Latch is set to off, electronic load operation will be activated if input voltage is higher than Von Voltage and electronic load operation will be terminated if input voltage is lower than Von Voltage. When Von Von Latch = ON...

Open the catalog to page 7
The PEL-3000E brochure - 8

Note : *1 - If the ambient temperature is over 30 °C or below 20 C, then T = ± t - 25 °C| x 100ppm/°C x Set Specifications subject to change without notice. EL-3000EGD1BH If the ambient temperature is in the range of 20°C~30°C, then T = 0 (t is the ambient temperature) OPTIONAL ASSESSORIES GTL-248 GPIB cable, 2.0m GTL-246 USB cable, Type A — Type B PEL-010 Dust Filter GU! inSTEK Simply Reliable ORDERING INFORMATION PEL-3031E 150V/60A/300W Programmable Single-channel D.C. Electronic Load PEL-3032E 500V/15A/300W Programmable Single-channel D.C. Electronic Load Quick Start Guide,...

Open the catalog to page 8