The brochure of PCS-1000I - 1

GW inSTEK Simply Reliable FEATURES •61/2 Digit Voltage and Current Measurement Resolution • Simultaneous Current and Voltage Measurement • Five Current Measurement Levels (AC & DC): 30mA/300mA/3A/30A/300A • AC Voltage Measurement Levels : 200mV/2V/20V/200V/600V • DC Voltage Measurement Levels : 200mV/2V/20V/200V/1000V • Standard: USB &GPIB • CE Verification

Open the catalog to page 1
The brochure of PCS-1000I - 2

GW Instek rolls out the new PCS-1000I isolated output high precision current shunt meter, which inherits the simultaneous voltage and current measurement function of PCS-1000. PCS-1000I adopts five sets of independent shunt resistors to provide five current measurement levels, including 300A, 30A, 3A, 300mA, and 30mA to meet the requirements of different current level measurements. Internally, PCS-1000I utilizes two sets of 24bits ADCs and low temperature coefficient electronic components to mainly focus on the current measurement of power supply devices. High precision PCS-1000I can be...

Open the catalog to page 2
The brochure of PCS-1000I - 3

AUTOMATIC RANGE-SWITCHING MEASUREMENT FUNCTION Press and hold Auto key, PCS-1000I will automatically select the maximum measurement resolution for users to save time in manual selection. PCS-1000I can simultaneously measure current and voltage with 6 1/2 measurement resolution. The left diagram shows the connection method of simultaneous measurement. Compared with the test of conventional meters from other brands, PCS-1000I is simple in connection and there is no requirement of any additional instrument. PCS-1000i Conducts Simultaneous Voltage and Current Measurement Shunt Resistor Conducts...

Open the catalog to page 3
The brochure of PCS-1000I - 4

Accuracy specification : ±(% of reading + % of range);voltage input resistance: 10MQ for all DC voltage ranges Isolated DC Current Monitor Accuracy Accuracy specification : ±(% of reading + % of range) Accuracy specification : ±(% of output + % of full scale); monitor output voltage for the full scale current = 3V; The specifications are only applicable when the input is 10% or greater of the full scale range Power Supply Power Line Frequency Operating Environment Storage Environment Power Consumption Dimensions Weight 100 V/120 V/220 V/240 V ±10% 50/60 Hz Full accuracy for 0 °C ~ 55 °C,...

Open the catalog to page 4