PRODUCT OVERVIEW - 1

PRODUCT OVERVIEW Temperature Transmitters, Alarm Units, Indicators, Signal Isolators, Configurations kits • Complete range of Transmitters for in-head and DIN-rail mounting App for wireless configuration and monitoring via NFC and Bluetooth Complete range of Loop Powered Isolators and Isolation Transmitters Alarm Units for monitoring of temperature and process signals Selection of Loop Powered Ind

Open the catalog to page 1
PRODUCT OVERVIEW - 2

Temperature transmitters Analog Adjustable 2-wire Transmitter Programmable 2-wire Transmitter for Pt100 sensors Basic Programmable 2-wire Transmitter Input: Output: Configuration: Accuracy: Approvals: Input: Output: Configuration: Accuracy: Input: RTD or T/C Output: 4-20mA Configuration: Solder pads, Potentiometers Accuracy: RTD ±0.15% of Span T/C ±0.5% of Span Approvals: ATEX (APAQ-H) RTD 4-20mA PC (via USB Interface) ±0.1% of Span ATEX & IECEx (IPAQ C202) Universal Programmable 2-wire Transmitter HART Universal 2-wire Transmitter HART® Universal Dual-input 2-wire Transmitter Input:...

Open the catalog to page 2
PRODUCT OVERVIEW - 3

Analog Adjustable 3-wire Transmitter 4-wire, High Isolation Temperature Transmitter Universal 1-channel programmable 2-wire Transmitter Input: Output: Configuration: Accuracy: Isolation: Input: RTD, T/C, Ω, mV Output: 4-20 mA / 20-4 mA Configuration: PC (via USB Interface) ±0.1% of Span Accuracy: Isolation: 1500 VAC Approvals: ATEX Input: RTD Output: 0-10 V Configuration: Solder pads or Potentiometers ±0.15% of Span Accuracy: Universal 2-channels programmable 2-wire Transmitter Analog 2-wire Transmitter for Potentiometer Input Input: RTD, T/C, Ω, mV Output: 4-20 mA / 20-4 mA Configuration:...

Open the catalog to page 3
PRODUCT OVERVIEW - 4

Isolators and Isolation Transmitters 1- & 2-channel Loop Powered Isolators for separation of 0(4)-20 mA Signals Transmitter repeater for powering and isolation of 2-,3- and 4-wire transmitters Signal Splitter/Repeater with double outputs for mA and V signals Type: Signal: Isolation level: Accuracy: Working Voltage: Housing: Type: Signal: Isolation level: Accuracy: Working Voltage: Housing: Type: Signal: Isolation level: Accuracy: Working Voltage: Housing: Passive mA 3 kv, 50 Hz ±0.1% FS 600 VAC/DC 6 mm line Active Transmitter 3 kv, 50 Hz ±0.1% FS 600 VAC/DC 6 mm line Active mA/V 3 kv, 50 Hz...

Open the catalog to page 4
PRODUCT OVERVIEW - 5

1- & 2-channel Loop Powered Isolators for Separation of 0(4)-20 mA Signals 1- & 2-channel Loop Powered Isolators for 0(4)-20 mA Signals with High Isolation and Protective Separation Basic Isolation Transmitter for Unipolar mA/V Signals with Calibrated Range Selection Type: Signal: Isolation level: Accuracy: Working Voltage: Housing: Type: Signal: Isolation level: Accuracy: Working Voltage: Housing: Type: Signal: Isolation level: Accuracy: Housing: Passive mA 3 kv, 50 Hz ±0.1% FS Standard line Passive mA 4 kv, 50 Hz ±0.1% FS 600 VAC/DC Standard line Active mA/V 2.5 kv, 50 Hz ±0.3% FS 600...

Open the catalog to page 5
PRODUCT OVERVIEW - 6

Isolation Transmitters with special features Isolation Transmitter for mA/V Signals with 2-wire Transmitter Supply Dual Channel Isolation Transmitter for mA/V Signals Programmable 2-wire Isolation Transmitter for mA Signals Input: Isolation level: Accuracy: Power Supply: Input: Isolation level: Accuracy: Power Supply: Input: Isolation level: Accuracy: Power Supply: mA, V 1500 VAC ±0.15% of span AC/DC versions mA, V 1500 VAC ±0.15% of span AC/DC versions Field housing and Indicators Loop Powered Heavy-duty LCD Field Indicator Loop Powered LCD Indicator for In-head Mounting Loop Powered &...

Open the catalog to page 6
PRODUCT OVERVIEW - 7

Alarm units & Power Supply Alarm Unit with Pt100 Input and Double Relay Outputs Alarm Unit with mA/V Input and Double Relay Outputs Alarm Unit with Pt100 Input and 4-20 mA Output Input: Typical Accuracy: Power supply: Input: Typical Accuracy: Power supply: Input: Typical Accuracy: Power supply: Current, Voltage ±0.2% of span 24 VAC/DC Dual Channel Alarm Unit with mA/V Input and Double Relay Outputs 4-channel Power Supply for 2-wire Transmitters Input: No. of channels: Typical Accuracy: Power supply: Voltage: Current limitation: Maximum ripple: Power supply: Current, Voltage 2 channels ±0.1%...

Open the catalog to page 7
PRODUCT OVERVIEW - 8

INOR product overview • Temperature Transmitters • Isolators & Isolation Transmitters • Field Housing & Indicators • Power Supply & Alarm Units • Temperature Sensors • Accessories © INOR 05/2019 4007629401 BR Product overview -R01-en Subject to change without notice. Contact Head office Inor Process AB PO Box 9125 SE-200 39 Malmö Sweden Phone: +46-(0)40-312560 E-mail: sales@inor.se www.inor.com Global partners and representatives The current list of all INOR contacts and addresses can be found at: www.inor