Overview: This document outlines the specifications and operational details of the autonomous oil circuit for machines with sleeve bearings, specifically for the SIMOTICS HV C and HV M series with order option K86. It is intended for use in environments where natural cooling is insufficient due to high speeds or ambient temperatures.
Description: The autonomous oil circuit serves as a replacement for external oil supply systems, providing necessary cooling and lubrication without requiring an external power supply. The system includes an integrated oil cooling mechanism, utilizing a heat sink and a rotor-connected pump to circulate oil through the bearings.
Operating Range: Applicable to HV M and HV C machines with shaft heights ranging from 450 to 900, across all cooling methods. It is designed for safe areas and is not suitable for marine applications. Additional space of up to 200 mm axially may be required, and side oil piping is necessary.
Technical Specifications:
  • Type of Construction: IM B3
  • Instrumentation: Includes bearing thermometer and monitoring
  • Lubricant: As per SN 63190
  • Temperature Range: -5 to 60 °C
Drawing Components:
  • Oil intake NDE
  • Oil intake at cooling system
  • Sight glass
  • Oil drain
  • Oil intake DE
  • Test point
See more

Catalog excerpts

K86-1

Autonomous oil circuit Order option K86 Description Machines with sleeve bearings that cannot be operated with natural cooling, e.g. due to excessive speed or ambient temperature, require an external oil supply. The external oil supply ensures cooling of the bearings and the lubricant supply. If an external oil supply cannot be provided, an autonomous oil circuit can be used as a full-fledged replacement. The system is self-sufficient, no separate line-side power supply connection is required. The integrated oil cooling system cools the oil without requiring an external oil and power supply. The heat sink cools the oil. A pump, which is directly connected to the rotor, draws in the oil and pumps it back to the sleeve bearing through the heat sink. A throttle valve and a flow meter are used to set the oil flow rate required. Operating range HV M and HV C, shaft heights 450-900, all cooling methods. Safe Area, no marine applications Additional space requirements: up to approx. 200 mm axially, depending on the version. Oil piping is required on the side. Technical specifications Type of construction Only with Bearing thermometer and monitoring Temperature range Department responsible Technical reference Document type Document status SIMOTICS HV C, HV M Order option K86 Document number Edition date (YYYY-MM-DD)

 Open the catalog to page 1
K86-2

Oil intake at cooling system Sight glass Test point Department responsible Technical reference Document type Document status SIMOTICS HV C, HV M Order option K86 Document number Edition date (YYYY-MM-DD)