video corpo

IK-009 - INDUSTRIAL RANGE
9Pages

{{requestButtons}}

Catalog excerpts

IK-009 - INDUSTRIAL RANGE - 1

POWER GENERATORS ilXIMESOL Model: IK-009 - INDUSTRIAL RANGE 400/230 V - THREE-PHASE | 1.500 R.P.M. | 50 Hz Genset with manual control panel. Image for guidance purposes. CONTINUOUS POWER: 8 kVA STAND-BY POWER: 9 kVA PRP “Prime Power” norma ISO 8528-1 LTP “Limited Time Power” norma ISO 8528-1 MAKE MODEL MAKE MODEL VOLTAGE HZ PHASE COS 0 PRP kVA/kW LTP kVA/kW AMP. (LTP) IlXIMESOL SotanoGroup■ Ctra. de Fuente Alamo, 2 | 30153 Corvera - Murcia ■ SPAIN www.inmesol.com ENG. These details shown on this data sheet are intended for guidance only. Inmesol reserves the right to change the details without prior notice. The present documents will not be part of any sales contract. ESP. Estos datos son meramente orientativos y pueden ser cambiados por el fabricante sin previo aviso. Inmesol se reserva el derecho a efectuar cambios en las especificaciones de dicho material. El presente documento no formara parte del contrato de adquisicion de bienes. FRA. Ces donnees sont purement indicatives et peuvent etre modifiees par le constructeur sans preavis. Inmesol a le droit d'apporter des modifications dans les specifications du materiau. Ce document ne fait pas partie du contrat d'acquisition de biens.

Open the catalog to page 1
IK-009 - INDUSTRIAL RANGE - 2

POWER GENERATORS IKI0009540T3110016M ilXIMESOL Model: IK-009 - INDUSTRIAL RANGE 400/230 V - THREE-PHASE | 1.500 R.P.M. | 50 Hz MAKE MODEL General Data Cooling system LIQUID Injection INDIRECT Suction NATURAL Series regulator - Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (°C) Electrical system VDC (V) Battery (Ah) Engine start-up (kW) IlXIMESOL SotanoGroup■...

Open the catalog to page 2
IK-009 - INDUSTRIAL RANGE - 3

POWER GENERATORS ilXIMESOL Model: IK-009 - INDUSTRIAL RANGE 400/230 V - THREE-PHASE | 1.500 R.P.M. | 50 Hz MAKE MODEL MECC-ALTE BTP 3-2S/4 General Data Power PRP (kVA) Power LTP (kVA) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X’d (%) X Degree of protection % POWER USED LITRES/HOUR 50% DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT Dimensions (mm) LENGTH WIDTH HEIGHT 1600 900 1132 FUEL TANK (LITRES) WEIGHT (KG) 47 550 NOISE LEVEL (dB (A)) 57 @ 7 m IlXIMESOL SotanoGroup■ Ctra. de Fuente Alamo, 2 | 30153 Corvera - Murcia ■ SPAIN ENG. These...

Open the catalog to page 3
IK-009 - INDUSTRIAL RANGE - 4

POWER GENERATORS Code: IKI0009540T3110016M Model: IK-009 - INDUSTRIAL RANGE 400/230 V - THREE-PHASE | 1.500 R.P.M. | 50 Hz INMESOL GENERATOR SET GENERAL DESCRIPTION The “INMESOL” generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. INMESOL S.L company...

Open the catalog to page 4
IK-009 - INDUSTRIAL RANGE - 5

Model: IK-009 - INDUSTRIAL RANGE Engine/alternator monobloc directly connected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Sealed chassis Fuel tank integrated in the base frame provided with fuel level jauge and fuel connections to the engine. Engine with mechanical...

Open the catalog to page 5
IK-009 - INDUSTRIAL RANGE - 6

Model: IK-009 - INDUSTRIAL RANGE DSE 3110 MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 3110 engine protection unit. Image for guidance purposes. 1. STARTER SWITCH 2. EMERGENCY STOP PUSHBUTTON 3. MEASURING INSTRUMENTS: Analogue(s) ammeter(s) Fuel level indicator. Analogue voltmeter Digital Hz display and hour meter (DSE 3110) Ctra. de Fuente Álamo, 2 | 30153 Corvera - Murcia · SPAIN ENG. These details shown on this data sheet are intended for guidance only. Inmesol reserves the right to change the details...

Open the catalog to page 6
IK-009 - INDUSTRIAL RANGE - 7

POWER GENERATORS IKI0009540T3110016M ilXIMESOL Model: IK-009 - INDUSTRIAL RANGE 400/230 V - THREE-PHASE | 1.500 R.P.M. | 50 Hz DSE 3110 MANUAL CONTROL PANEL 4. SET CONTROL AND ENGINE PROTECTION: DSE 3110, allows: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL Digital readings of the operating hours and the Frequency Controls the main characteristics of the engine, causing an alarm or stopping the machine: ■ Low and High Voltage (STOP) ■ Low and High Frequency and Speed (STOP) ■ Low Oil Pressure and High Coolant Temperature (STOP) ■ Failure of the...

Open the catalog to page 7
IK-009 - INDUSTRIAL RANGE - 8

Model: IK-009 - INDUSTRIAL RANGE OPTIONS OPTIONAL 1: AUTOMATIC PANEL FOR MANUAL GENERATOR: ATS DSE 334 This panel provides the manual control generator with a reserve operation from the Mains, as the ATS sends the command to start and stop the generator, when it detects a supply failure and when the Mains is restored. Image for guidance purposes. It has the following: Change over switch made up of two contactors with mechanical and electrical latching. Battery charger Fuses Mains and group input and charge output connection terminal block. DSE 334 Automatic Transfer Control Module,...

Open the catalog to page 8
IK-009 - INDUSTRIAL RANGE - 9

Model: IK-009 - INDUSTRIAL RANGE OPTIONS OPTION 2: FAILOVER TO DSE 6110 MKII MANUAL DIGITAL CONTROL MODULE LCD SCREEN: It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR and CHARGING. Coolant temperature Voltages between phases and between phases and neutral. Fuel level Battery voltage Battery alternator voltage Operating hours Number of start-ups CONTROL OF THE SET: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL. PROTECTION OF THE ENGINE AND ALTERNATOR, WITH THE ALARMS ACTIVATED: ENGINE:...

Open the catalog to page 9

All Inmesol catalogs and technical brochures

  1. IP-1620

    8 Pages

  2. AL 1200-E

    2 Pages