Liquid Cooled Technology Cold plate liquid cooled heater/cooler Heating, cooling and shaking in one liquid cooled device

 Open the catalog to page 1
Thermoshake AC LC-3

Liquid Cooled Technology Inheco’s liquid-cooled devices replace the usual on-deck heat sink/fan combination with liquid heat exchangers and transfer heat to the environment via a heat exchanger outside the deck. For assays that require high precision there’s less risk of disturbance or contamination from waste heat generation or air movement from fans. On-deck liquid cooled device Off-deck heat exchanger Liquid with waste heat Cooled liquid Liquid Cooled Technology

 Open the catalog to page 3
Thermoshake AC LC-4

Cold plate liquid cooled heater/cooler Heat, cool or freeze your samples, not your deck! Heat and cool samples precisely, without fear of contamination. Our Peltier-based heater/cooler uses liquid cooling for near-silent operation without generating waste heat or air on deck. Labs report problems with on-deck waste heat that increases the ambient temperature of the deck, air movement from fans increases the risk of sample cross-contamination, and there’s excessive noise when many devices work together. Cold plate liquid cooling moves heat dispersal off deck and can solve those problems. On-deck...

 Open the catalog to page 4
Thermoshake AC LC-5

Application examples

 Open the catalog to page 5
Thermoshake AC LC-6

When your application needs cooling or heating surfaces, Peltier technology is often preferred. It offers heating and cooling plus temperature control all in one unit. But if your units discharge waste heat or air on-deck they can cause excess heat or sample contamination, as well as noise. Moving heat exchange off-deck eliminates those problems. What to look for in a heater/cooler? Accurate and uniform heating and cooling are important, as are the ability to maintain temperature precisely. Depending on your set-up, contamination risk and noise may also determine your choice. Cooling capability...

 Open the catalog to page 6
Thermoshake AC LC-7

Technical data TECHNICAL DATA INCLUDING DIMENSIONS CPLC type Heating mode Cooling mode Input voltage / max. current Temperature range Temperature cycling Max. reachable temperature difference Sensor type Inlet and outlet hose connection in mm Outer diameter 8; inner diameter 6 Outer dimensions for length x width in mm Outer dimensions for height in mm Weight incl. cord Outer diameter 12.7; inner diameter 7.6 ENVIRONMENTAL CONDITIONS Tolerable relative humidity *Condensate can prevent the CPLC from operating properly and can damage the CPLC. Condensate should be eliminated on a daily basis or...

 Open the catalog to page 7
Thermoshake AC LC-8

Thermoshake AC LC Heating, cooling and shaking with active clamping and liquid cooling Precise heating, cooling & shaking in one small device! Combined heater/coolers and shakers can be problematic when working without on-deck air-conditioning. Labs report problems with on-deck waste heat that increases the ambient temperature of the deck, air movement from fans increases the risk of sample cross-contamination, and there’s excessive noise when many devices work together. Liquid cooling moves heat dispersal off deck and can solve those problems. Save precious deck space with one device that delivers...

 Open the catalog to page 8
Thermoshake AC LC-9

Application examples

 Open the catalog to page 9
Thermoshake AC LC-10

Heating, cooling and maintaining ambient temperatures, while shaking, are fundamental to many life sciences processes carried out in an automated liquid handling deck. When on deck space is at a premium, it makes sense to use one multi-functional combined device – but only when you can be sure performance won’t be compromised. • The Thermoshake AC LC shakes using an What to look for in a combined thermoshaker? Accurate uniform heating, cooling and shaking for every sample are the prerequisites for thermoshakers. That means ensuring that your samples are safely clamped during the shaking, and...

 Open the catalog to page 10
Thermoshake AC LC-11

Technical data TECHNICAL DATA INCLUDING DIMENSIONS Product number Height (bottom to contact surface) Height with standard fixation pins Temperature range Maximum temperature difference in cooling mode ΔT (= Tambient - Ttarget ) Protection category Weight including cables TECHNICAL INFORMATION REGARDING SHAKING FOR ALL DEVICES Maximum load Shaker frequency (Weight reduces the max. speed) Shaking amplitude Shaking pattern *D epending on the load, as otherwise liquid might get spilled or adapter might not be hold tight to the clamp mechanism. We recommend to test the speed you want to use with a...

 Open the catalog to page 11
Thermoshake AC LC-12

About Inheco Market-leading, Customer-led devices for automated liquid handling platforms We’ve been designing, making and supplying devices for automated liquid handling platforms for more than 20 years. Our customers include major manufacturers, integrators and end-users in big pharma, biotech, diagnostics and research & academia. We develop our products based on our customer needs, market knowledge and innovative strength. Reliable and supported Every Inheco device is designed, engineered and made in Germany and undergoes rigorous quality control before delivery. It comes with a global two-year...