video corpo

INGESCO CATALOGUE-EN
1 / 50Pages

Catalog excerpts

INGESCO CATALOGUE-EN - 2

Since 1973, INGESCO has been a specialist in solutions for the prevention and protection against lightning. Reference We are the leading company in the design, manufacture and control systems for the prevention and protection against lightning. International vocation We export to over 60 countries worldwide. Our comprehensive and analytical view has made us one of the most advanced companies in the sector worldwide. Comprehensive and transversal We offer a comprehensive and transversal service. We cover all stages, from research and development to installation and certification. Tailored...

Open the catalog to page 2
INGESCO CATALOGUE-EN - 3

TABLE OF CONTENTS EXTERNAL LIGHTNING PROTECTION GROUNDING SYSTEMS CONTROL SYSTEMS SURGE PROTECTION THUNDERSTORM WARNING SYSTEMS

Open the catalog to page 3
INGESCO CATALOGUE-EN - 4

EXTERNAL LIGHTNING PROTECTION INGESCO® PDC ESE LIGHTNING RODS INGESCO® PDC.E ESE LIGHTNING RODS LIGHTNING RODS CAPTURE SYSTEM ACCESSORIES FASTENING AND CONNECTING ACCESSORIES DOWN-CONDUCTOR PROTECTION SPARK GAPS

Open the catalog to page 4
INGESCO CATALOGUE-EN - 5

EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | INTRODUCTION: PDC (ESE) LIGHTNING RODS  standards a) If 2m≤ h ≤ 5m: Rp= h * Rp(5) 5 Implementing rules for an effective person and property protection system: · UNE 21186:2011: Lightning protection - Lightning rods with priming device. · NF C 17-102:2011: Early streamer emission lightning protection systems. · NP 4426:2013: Lightning protection - systems with non-radioactive ionization device. In addition to these, there may be legislation or rules of each country that must be taken into account....

Open the catalog to page 5
INGESCO CATALOGUE-EN - 6

EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | INTRODUCTION: CONVENTIONAL LIGHTNING RODS - CAPTURE MESHES  standards In order to design an effective lightning protection system with Franklin rods or capturing meshes, the following rules shall apply: · IEC 62305:2010 Lightning protection (Parts 1, 2, 3 y 4). · UNE - EN 62305:2011 Protection against lightning (Parts 1, 2, 3 y 4). · NFPA 780:2020 Standard for the installation of lightning protection systems. In addition to these rules, legislation in each country must be taken into account. Fig....

Open the catalog to page 6
INGESCO CATALOGUE-EN - 7

EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | EXTERNAL LIGHTNING PROTECTION | INTRODUCTION | DOWN CONDUCTORS  ESE down conductors  Conventional LPS down conductors The down conductors are intended to conduct lightning current from the collection devices to the grounding. In order to reduce the likelihood of damage due to lightning currents circulating in the LPS, down conductors must be arranged so that from the point of impact grounding is: Protection Level Distance between conductors Table 6 – Distance between down conductors IEC 62305-3. It is also advisable to place the down...

Open the catalog to page 7
INGESCO CATALOGUE-EN - 8

EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC LIGHTNING ROD | INGESCO® PDC (ESE) LIGHTNING RODS Product certified by Certification Non-expendable 5 year warranty Natural field trials  technical specifications Lightning rod with non-electronic streaming. Suitable for external lightning protection of all types of structures and open areas. · Level of protection rated as very high. · 100% effective in discharge. · Electrical continuity guaranteed · Retains all its initial properties after each discharge so does not require specific maintenance. · Operation guaranteed in any atmospheric...

Open the catalog to page 8
INGESCO CATALOGUE-EN - 9

EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC LIGHTNING ROD | EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC LIGHTNING ROD | Coverage radius (m) INGESCO PDC 3.1 according to protection level and height (UNE 21186:2011, NFC 17-102:2011 and NP 4426:2013) Coverage radius (m) INGESCO PDC 5.3 according to protection level and height (UNE 21186:2011, NFC 17-102:2011 and NP 4426:2013) LEVEL II LEVEL III LEVEL IV ∆t : 15µs r: Radius of the rolling sphere L-I : r = 20 m L-II : r = 30 m L-III : r = 45 m L-IV : r = 60 m LEVEL II LEVEL III LEVEL IV ∆t : 43µs r: Radius of the rolling sphere L-I : r = 20 m...

Open the catalog to page 9
INGESCO CATALOGUE-EN - 10

EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC.E LIGHTNING ROD | INGESCO® PDC.E LIGHTNING ROD Product certified by Certification  technical specifications Lightning rod with ELECTRONIC streaming. Natural field trials Suitable for external lightning protection of all types of structures and open areas. · Level of protection rated as very high. · Requires no external power source. · 100% effective in discharge. Maximum durability. · Guaranteed operation after lightning strike and in any weather condition. · Made of AISI 316L stainless steel. · Authentication system using QR code. · Laser...

Open the catalog to page 10
INGESCO CATALOGUE-EN - 11

EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC.E LIGHTNING ROD | EXTERNAL LIGHTNING PROTECTION | INGESCO® PDC.E LIGHTNING ROD | INGESCO® PDC.E 15 LIGHTNING ROD INGESCO® PDC.E 60 LIGHTNING ROD  Coverage radius (m) INGESCO® PDC.E 15 according to protection level and height (UNE 21186:2011, NFC 17-102:2011 and NP 4426:2013) LEVEL II LEVEL III LEVEL IV ∆t : 15µs r: Radius of the rolling sphere L-I : r = 20 m L-II : r = 30 m L-III : r = 45 m L-IV : r = 60 m  Coverage radius (m) INGESCO® PDC.E 30 according to protection level and height (UNE 21186:2011, NFC 17-102:2011 and NP 4426:2013) PDC.E 60...

Open the catalog to page 11
INGESCO CATALOGUE-EN - 12

EXTERNAL LIGHTNING PROTECTION | LIGHTNING RODS | SIMPLE RODS LIGHTNING RODS ALUMINIUM simple lightning rods Model Termination rods suitable for external lightning protection. It can be used as single sensor element or part of protection, complementing the protection conductive mesh (Faraday cages). Made of AISI 316L stainless steel or copper. Tested by UL test report number: 4789563988.1. Please consult for other materials or dimensions. Simple rods Multiple rods MULTIPLE RODS SIMPLE RODS  COPPER simple lightning rods Model MULTIPLE RODS WITH MAST ADAPTOR  Multiple lightning rods with...

Open the catalog to page 12
INGESCO CATALOGUE-EN - 13

EXTERNAL LIGHTNING PROTECTION | LIGHTNING RODS | SPECIAL LIGHTNING RODS CAPTURE SYSTEM ACCESSORIES For application in electrical substations and others.  COPPER lightning rods with COPPER-PLATED STEEL horizontal support Model H Adaptor parts Accessories for installing the capture system. Adaptor parts, masts and anchoring systems. Masts Fastening Adjustment parts for lightning rods made by INGESCO (simple tips, multiple and ESE) of Ø16mm or 20mm. It facilitates the connection of the lightning rod to the conductive network. Masts for fastening and support for termination rods to structures...

Open the catalog to page 13