Catalog excerpts

MOVINOR_LH055_LH086_LH097_LH142 (1)-1

MOVINOR LH Series Synchronous Servomotors LH055 – LH086 – LH097 – LH142 Windings 320 VDC / 560 VDC

 Open the catalog to page 1
MOVINOR_LH055_LH086_LH097_LH142 (1)-2

Improvement of motors subject to technical alterations. No part of this document is allowed to be reproduced in any form (by either print, photocopy or any other method) without the written agreement of INFRANOR SA.

 Open the catalog to page 2
MOVINOR_LH055_LH086_LH097_LH142 (1)-4

Safety advices ¾ All operations on transport, assembly, setup and maintenance have to be done by skilled and qualified personnel. The qualified personnel must know and observe the following standards and guidelines: DIN VDE 0105, IEC 364, accident prevention regulations Inproper conduct may cause serious injury to persons and lead to damage. ¾ Before mounting and putting into operation read carefully the documents on hand. Follow the instructions for power supply (motor label and manual) and go by the rules of the technical data. ¾ Ensure a proper, low-impedance earth of the motor frame with...

 Open the catalog to page 4
MOVINOR_LH055_LH086_LH097_LH142 (1)-5

> Synchronous servomotors within the LH055-LH142 range are precision motors. They are not foreseen to be connected directly to a three-phase power. They have to be operated only by a particular electronic power stage. A direct connection to main supply will lead to the destruction of the motor. > To wind up drive elements without backlash strictly use the foreseen thread within the motor shaft and if possible warm up the drive elements. Only use suitable aids to wind up the drive elements. > Avoid strong punches to the motor flange and the motor shaft. > Take care that the coupling is correctly...

 Open the catalog to page 5
MOVINOR_LH055_LH086_LH097_LH142 (1)-6

4.1. About this manual This manual describes the synchronous servomotors of the LH055–LH142 range and it is directed towards specialist staff having knowledge of electrical and mechanical engineering. The servomotors are operated together with the corresponding servo drives. Therefore absolutely follow the documentation of the servo drive too. 4.2. Use in accordance with the requirements Synchronous-servomotors are specially designed to run machines with high requirements to dynamics. It is only allowed to operate the motors taking into consideration the environmental conditions described in...

 Open the catalog to page 6
MOVINOR_LH055_LH086_LH097_LH142 (1)-7

The power transmission is effected by the cylindrical shaft-A end. Please take into consideration that high radial forces will occure when motors are driven via pinions or toothed belts. The values permitted at the shaft end depend on the number of rotations. The crest value at 3000 rpm is shown in the chart below. In case of acting force at the middle of the free shaft end, FR can be above 10%. Double conical gripping collets, probably combined with metal bellows couplings proved to be ideal coupling elements. Flange sizes according to IEC-standards, fit j6, accuracy as per DIN 42955 Tolerance...

 Open the catalog to page 7
MOVINOR_LH055_LH086_LH097_LH142 (1)-8

The mating connectors are not included with the delivery. These, as well as completely assembled cables are available on request. The motors have the option of an installed brake. The permanent-magnet brake is operated by 24 VDC and blocks the rotor in voltageless state. The brake is to be understood as a standstill brake and it is not to be used for permanent slow downs during production. When brake is disengaged the rotor can operate without time lag, the operation is free from backlash. The brakes can be operated directly by the power stage (no personal safety !). In this case the erasing...

 Open the catalog to page 8
MOVINOR_LH055_LH086_LH097_LH142 (1)-9

4.6. Type code for MOVINOR motors LH055-LH142 1 3) Torque & length size: 1 for lower, 2 for second, etc. 4) Winding (DC bus voltage): C: 320V, D: 560V, E: 125V, S: customer specific 5) Shaft: 0: standard with keyway, 1: standard without keyway 6) Front flange: 0: standard, 1: with shaft seal 02: ERN 1185 SinCos with commutation signals 03: ERN 1387 SinCos with commutation signals 04: ECN 1113 single EnDat® 12: CNS50 incremental 2048 & commutation signals 13: CNS50 incremental 4096 & commutation signals 14: R22i incremental 1024 & commutation signals 15: CKS36 incremental 2048 & prog. commutation...

 Open the catalog to page 9
MOVINOR_LH055_LH086_LH097_LH142 (1)-10

Installation / Setup 5.1. Important notes ¾ Check the relation between power stage and motor. Compare rated voltage and nominal power of the appliances. The wiring has to be carried out in accordance to the circuit diagram shown in the installation/operation manual of the power stage. ¾ Pay attention to strong earth connection of power stage and motor. ¾ Route the power and control cables separately from each other. When using motor power cables with integrated brake wires, the brake wires should be shielded. The shield weave has to be put on both sides. ¾ Lay all circuits with sufficient cross...

 Open the catalog to page 10
MOVINOR_LH055_LH086_LH097_LH142 (1)-11

5.3. Environmental conditions With regard to the installation site of the motor please take into consideration the environmental conditions like ambient temperature: -20...+40°C, maximum mounting height: 1000m above sea level, relative humidity: 15...85%, noncondensing. A power reduction might possibly be necessary in case of tolerances to the a.m. environmental conditions. The motors are not suitable for outdoor installation or installation within aggressive or foreign substance afflicted atmosphere. 5.4. Drive elements The rotor of the motor has been electronically counterbalanced during production....

 Open the catalog to page 11
MOVINOR_LH055_LH086_LH097_LH142 (1)-12

Dimensions Type Mo, Mn and Nn. values ascertained with heat sink.

 Open the catalog to page 12
MOVINOR_LH055_LH086_LH097_LH142 (1)-14

Dimensions Type Mo, Mn and Nn. values ascertained with heat sink.

 Open the catalog to page 14
MOVINOR_LH055_LH086_LH097_LH142 (1)-16

Dimensions Type 10% tolerance at Mo, Mn and Nn. values ascertained with heat sink.

 Open the catalog to page 16
MOVINOR_LH055_LH086_LH097_LH142 (1)-18

Dimensions Type Mo, Mn and Nn. values ascertained with heat sink.

 Open the catalog to page 18
MOVINOR_LH055_LH086_LH097_LH142 (1)-20

MOVINOR LH055—LH142 : INFRANOR standard wiring Motor plug Resolver / Hiperface plug Incremental encoder plug = Intercontec Typ B, Size 1, 6 pol. = Intercontec Typ A 12-pol.

 Open the catalog to page 20
MOVINOR_LH055_LH086_LH097_LH142 (1)-21

Motor plug = Intercontec Typ B, Size 1, 6 pol. Heidenhain absolute & EnDat encoder plug = Intercontec Typ A 17-pol.

 Open the catalog to page 21
MOVINOR_LH055_LH086_LH097_LH142 (1)-22

Oil seal against oil mist and shower oil Counter plug for motor connection Intercontec Type B, size 1, 6 poles Counter plug for resolver connection Intercontec Type A, 12 poles Various converted cables on request. Directed to either A or B-side, or turnable Motor Feedback - various feedback systems on request

 Open the catalog to page 22

All Infranor Group catalogs and technical brochures

  1. smt-100

    32  Pages

  2. PacSimBox_e

    1  Page

  3. Pac_SF01_EN

    4  Pages

  4. Option_CT_EMF

    6  Pages

  5. ma_series

    6  Pages

  6. CD1a_e_7.1(old)

    45  Pages

  7. BM20A(F)v3_0

    20  Pages

  8. BM20A(D)v3_0

    20  Pages

  9. BF400(GB)v2_2

    21  Pages

  10. BF400(D)v2_2

    21  Pages

  11. BF230(GB)v2_0

    23  Pages

  12. BF230(F)v2_0

    23  Pages

  13. BD2m_e_2.2

    69  Pages

  14. BD2m(GB)2.0

    70  Pages

  15. BD2_e_3.2

    53  Pages

  16. BD2(GB)3.1

    53  Pages

  17. BD2(D)3.1

    54  Pages

  18. Movinor_LH_e

    4  Pages

  19. ma_series

    6  Pages

  20. BD1t(GB)3.1

    81  Pages

  21. BD1t(F)3.0

    85  Pages

  22. BD1pInst(GB)3.0

    25  Pages

  23. BD1pInst(F)3.0

    23  Pages

  24. BD1pInst(D)3.0

    24  Pages

  25. BD1m(GB)5.0

    58  Pages

  26. BD1m(F)5.0

    57  Pages

  27. BD1m(D)v3_3

    64  Pages

  28. BD1k(GB)2.1

    35  Pages

  29. BD1k(F)2.1

    36  Pages

  30. BD1j(GB)v2_41

    19  Pages

  31. BD1j(F)v2_4

    21  Pages

  32. BD1i(GB)v2_21

    23  Pages

  33. BD1i(F)v2_2

    27  Pages

  34. BD1h(F)3.0

    65  Pages

  35. BD1h(D)3.0

    59  Pages

  36. BD1g(GB)v3_0

    28  Pages

  37. BD1g(F)v3_0

    28  Pages

  38. BD1f(GB)v2_01

    18  Pages

  39. BD1f(F)v2_01

    17  Pages

  40. BD1e(F)v2_01

    22  Pages

  41. BD1d(GB)v2_01

    25  Pages

  42. BD1d(F)v2_01

    25  Pages

  43. BD1c(GB)v2_01

    19  Pages

  44. BD1c(F)v2_01

    19  Pages

  45. BD1a400(GB)v2_3

    43  Pages

  46. BD1a400(F)v2_3

    44  Pages

  47. BD1a400(D)v2_3

    45  Pages

  48. BD1(GB)7.1_noPW

    45  Pages

  49. BD1(GB)7.1

    45  Pages

  50. BD1(F)7.1_noPW

    47  Pages

  51. BD1(F)7.1

    47  Pages

  52. BD1(D)7.1

    45  Pages

  53. BD1 Katalog

    11  Pages

  54. 08ma_ms_e_01700

    20  Pages

  55. Easy_STO_en_1.4

    14  Pages

  56. CD1kUser_en_2.3

    26  Pages

  57. CD1a_en_8.17

    62  Pages

  58. CD1_STO_en_1.8

    16  Pages

  59. Drawing_1

    1  Page

  60. Datasheet_MSS

    5  Pages

  61. Datasheet_2

    2  Pages

  62. Datasheet_1

    4  Pages

  63. BLSBLT_series

    2  Pages

  64. BL220221

    2  Pages

  65. BL270

    2  Pages

  66. BL190

    2  Pages

  67. bl100_series

    6  Pages

  68. bl40_series

    6  Pages

  69. BL30

    2  Pages

  70. Movinor_T_EN

    4  Pages

  71. Movinor_N_EN

    4  Pages

  72. CybIO

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.