Overview: INFIGROUP specializes in combustion expertise, offering solutions for the incineration of various waste types including animal, hospital, municipal solid, and special industrial waste. Their FRI range of incinerators supports continuous operation up to 24 hours and includes advanced features for efficient waste destruction and emission control.
Specifications: The FRI range includes models with hourly destruction capacities from 500 kg/h to 5,000 kg/h. Each model features a primary combustion chamber and a post-combustion system to ensure complete waste oxidation. The combustion chamber operates at temperatures between 850°C and 1,150°C, while post-combustion temperatures range from 1,150°C to 1,250°C.
Loading and Ash Removal: The incinerators are equipped with automatic loading systems for both solid and liquid waste, minimizing heat loss. Automatic de-ashing systems are programmable, allowing for efficient ash removal before or after incineration cycles.
Emission Filtration: INFIGROUP provides various filtration methods, including a ceramic filter system that complies with CE standards. This system captures microparticles using reagents and is essential for installations processing over 500 kg/h.
Energy Recovery: The incinerators can be equipped with Energy Packs to recover combustion heat for electricity generation, hot water production, or cooling applications. This includes options for ORC systems and steam turbines.
Environmental Impact and Certification: All solutions are CE certified, ensuring high standards in health, safety, and environmental protection. INFIGROUP is committed to developing clean and efficient waste management solutions.
Manufacturing and Global Reach: INFIGROUP designs and manufactures its equipment, offering services from simple equipment provision to full assembly and training. The company operates internationally, supported by a network of agents and distributors.
See more

Catalog excerpts

FRI RANGE-1

565, Avenue du Prado 13008 Marseille France TOTAL WASTE TREATMENT \ Rotary kiln incineration lines from 500 kg/h to 5,000 kg/h - Animal Waste - Hospital Waste - Municipal Solid Waste - Miscellaneous Solid & Liquid Waste - Special and Dangerous Industrial Waste The FRI range allows daily working time up to 24 hours. FRI equipment is made in two steps, including a primary combustion chamber, with a hot-hearth construction, which ensures the total destruction of the waste. An integrated post-combustion system completes the process, to guarantee maximum gas turbulence, and ignite the gases which remained unburnt during the first combustion. These gases are maintained for a minimum of 2 seconds at temperatures from 900°C to 1200°C, thus ensuring complete incineration of its components (oxidation). INFIGROUP, COMBUSTION EXPERTISE

 Open the catalog to page 1
FRI RANGE-2

SOLID WASTE LOADING AUTOMATIC DE-ASHING The FRI series incinerators are designed for automatic loading with hydraulic assistance. Loads of all types of waste are done through a front access, which reduces heat loss during loading. The discharge located under the incinerator is separated from the combustion chamber by means of a hydraulically controlled ashes removal hatch. The ashes extraction operation is programmable and can be carried out before the start of a new cycle, or at the end of the cycle. LIQUID WASTE LOADING The option for automatic loading by pneumatic assisted injectors, of liquid,...

 Open the catalog to page 2
FRI RANGE-3

FILTRATION OF EMISSIONS (FUMES) There are different possibilities. From the incineration process, by pyrolysis or oxidation, the waste is transformed into fumes which must be treated. INFIGROUP offers all kinds of different filtration methods, up to the adapted dry treatment (ceramic) which complies with CE standards. For sizes of 500kg/h and over, only ceramic filtering is to be considered. Ceramic filtration is a combination of cyclone filter and ceramic filter. It is the only one certified 100% CE. Its role is to regulate the flow of releases from gases in the event that the installation does...

 Open the catalog to page 3
FRI RANGE-4

SPECIFICATIONS DESCRIPTION Hourly destruction capacity (kg/h) Maximum Loading capacity in one load (kg) Calorific power of waste (LHV in th/kg/h) Combustion chamber volume (Liters) Total thermal capacity (KWth) Thermal power available for recovery (kWth) Combustion chamber temperature (°C) Burners in combustion chamber Post-combustion burners Recommended dimensions for the concrete slab l x w (m) Chimney height (m) (for indication only) Total Weight (tons) Acceptable Fuel Shredder option with liquid separation Automatic loading option Liquid injector + tank + pump option Energy Pack Option Smoke...