1. Catalogs
  2. inelta Sensorsysteme
  3. Miniature Displacement sensors Type IKAL

Miniature Displacement sensors Type IKAL

Miniature Displacement sensors Type IKAL

Miniature Displacement sensors Type IKAL

Product catalog summary
Overview: The document provides technical specifications and application details for the LVDT-IKAL series inductive displacement sensors by Inelta Sensorsysteme GmbH & Co. These sensors operate on the principle of the differential transformer and are designed for various industrial and medical applications.
Specifications:
  • Housing Diameter: 8mm
  • Stroke Options: ±1, ±2.5, ±5, ±10mm
  • Protection Degree: IP65
  • Contactless and Wear-Free: Ensures longevity and reliability
  • Custom Designs: Available upon request
Applications:
  • Displacement and position detection
  • Industry and medical engineering
  • Machine and plant design
  • Agriculture and navy
  • Testing facilities and special machine design
Electrical Specifications:
  • Sensitivity: Varies with stroke length (e.g., 130 mV/V/mm for ±1mm stroke)
  • Linearity Tolerance: < ±0.5% (optional < ±0.25%)
  • Supply Voltage: 1..3 V RMS
  • Supply Frequency: 1..40 kHz
  • Input Resistance: Varies with stroke length (e.g., 56 Ohm for ±1mm stroke)
  • Temperature Coefficient: < ±0.05% F.S./°C
Mechanical Specifications:
  • Housing Material: Steel, nickel-plated
  • Core Material: Nickel-Iron Alloy/Ferrite
  • Weight: 30g (with cable), 1.5g (core)
Environmental Conditions:
  • Operating Temperature: -25 to +85°C
  • Storage Temperature: -40 to +85°C
  • Shock Resistance: 200 g/2ms
  • Vibration Resistance: 10g / 2 Hz to 2 kHz
Options:
  • Extended temperature range
  • Custom cable lengths
  • Improved linearity tolerance
  • Additional options available upon request
Connection Details: The document provides a color-coded guide for cable connections, specifying primary and secondary signals.
Order Code: The series and stroke options are detailed, with linearity tolerance options specified.
Additional Resources: A brochure with application examples and user guides is available for download from the company's website.
See more

Catalog excerpts

Miniature Displacement sensors Type IKAL-1

Prinzip des Differentialtransformators Principle of the differential transformer > Erweiterter Temperaturbereich / Extended temperature range Andere Kabellnge auf Anfrage (Standard = 1m) / Other cable lenght on request (standard = 1m) Bessere Linearittstoleranz (< 0,25%) / Improved linearity tolerance (< 0,25%) Schutzart IP65 / Protection degree IP65 Weitere Optionen auf Anfrage / More options on request inelta Sensorsysteme GmbH & Co. 䤷 Haidgraben 9a D-85521 Ottobrunn/M׼nchen, Germany Phone +49 (0)89/45 22 45 - 0 Fax +49 (0)89/45 22 45 ז 244 eMail: [email protected] ׷ www.inelta.de >

 Open the catalog to page 1
Miniature Displacement sensors Type IKAL-2

Messweg Stroke 1ѱ2,55ѱ10[mm]Empfindlichkeit Sensitivity 1301056045[mV/V/mm]Linearittstoleranz Linearity tolerance < 0,5 (< 䱱0,25 optional)[% F.S.]Erregerspannung Supply voltage 1..3[V RMS]Erregerfrequenz Supply frequency 1..40[kHz]Primrwiderstand typ. Input resistance typ. 5675105200 [Ohm]Primrimpedanz typ. Input impedance typ. 610 [Ohm]Ausgangsimpedanz typ. Output impedance typ. 520 [Ohm]Temperaturkoeffizient Temperature coefficient < 䤱0,05[% F.S./C]Kalibrierung bei 3V RMS / 20 kHzRL = 1MOhm Calibrated supply > GehФusematerial Stahl vernickelt Housing material Steel nickeling plated Kernmaterial...

 Open the catalog to page 2
Miniature Displacement sensors Type IKAL-3

Kabelfarbe Signal Colour of cable Signal wei Prim䟤r 1 (3)(4) (5)(1)(2) white Primary 1 braun Primr 2 brown Primary 2 gelb Sekundr 1 yellow Secondary 1 gr䤼n Sekundr 2 green Secondary 2 grau Sekundr 1, 2 Mitte grey Secondary 1, 2 Centre Geh䤤use Schirm Housing Shield > Typ / Type IKAL2IKAL5IKAL10IKAL20 Messweg / Stroke ߱12,5ѱ510[mm]L137526696[mm]Mechanische Weg M1 Mechanical stroke M1 60 (vorlѤufig)[mm] inelta Sensorsysteme GmbH & Co. Haidgraben 9a ׷ D-85521 Ottobrunn/Mnchen, Germany Phone +49 (0)89/45 22 45 - 0 Fax +49 (0)89/45 22 45 췖 244 eMail: [email protected] ׷ www.inelta.de >

 Open the catalog to page 3
Miniature Displacement sensors Type IKAL-4

Serie Messweg [mm] Lin.-Toleranz* Series Stroke Lin.-Tolerance* IKAL-5- *in case of < 0,25% 2 = ѱ15 = 2,5 10 = ѱ5 20 = 10*nur wenn < ѱ0,25% Standard Standard Optionen Andere auf Anfrage Options Other on request 0,25% www.inelta.de > Datasheet Serie / Series IMA2-LVDTISM-LVDTIVM2-LVDT Ausgangssignale / Output signals 0..5 V, 0..10 V, 5 V, ѱ10 V, 0..20mA, 4..20 mA0..10 V, 4..20 mA0..10 V Datenblatt PDF Downloadwww.inelta.de/service > Die Broschre zum Produkt mit Applikationsbeispielen und Benutzerhinweisen finden Sie im Internet unter www.inelta.de/service Suitable for this product you can download...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.