Technical Introduction
The INCINER8 I8-500G is a state-of-the-art incinerator designed for efficient medical waste disposal. It features a cladded design for heat retention and hygiene control, a patented safety handle, and a high-quality refractory lining. The CE5 control panel allows for programmable temperature control, ensuring complete combustion with low energy consumption.

Features
The I8-500G includes a secondary chamber with a 2-second retention time, fast pre-heat capabilities, and a large loading chamber accommodating up to 350kg of waste. It is constructed from heavy-duty steel with hydraulic doors for easy operation. The Coretex insulation technology enhances heat retention and efficiency.

Technical Breakdown
Incineration converts waste into ash, heat, and flue gas. The process involves a primary and secondary combustion chamber, with independent temperature control to maximize efficiency. The system includes HT thermocouples, low NOx burners, and a stainless steel chimney stack.

Applications
The I8-500G is versatile, suitable for various waste types including general, plastic, camp, domestic, industrial, and document waste. It is compatible with auto loaders and designed for easy operation with minimal staff.

Operational Specifications
The incinerator operates at a recommended temperature of 850°C, with a burn rate of 30-40 kg per hour. It features a top-loading method, light oil or gas/LPG fuel options, and a control panel with an IP57 rating. The assembled dimensions are 5000 x 2800 x 5750 mm, with a weight of 18000 kg.

Technical Specifications
The secondary combustion chamber operates between 850 - 1200°C to minimize emissions. The system complies with ISO 9001 and VISION 2000 standards, featuring Ecoflam burners for high efficiency and low NOx emissions.

Average Emissions / EU Standards
The I8-500G meets EU emission standards with low levels of sulphur dioxide, total dust, carbon monoxide, and nitrogen dioxide. The emissions are largely dependent on the waste materials, and appropriate pollution control methods should be selected to ensure compliance.

For further information, contact INCINER8 at +44 (0) 1704 884020 or email [email protected].
See more

Catalog excerpts

i8-500G General Waste Incinerator Datasheet-2

TECHNICAL INTRODUCTION One of our newest systems is the i8-500, It uses groundbreaking design and uses features found on our much larger machines. The i8-500 took over two years to develop and was designed from the ground up to offer impressive burn rates and large batch sizes while still achieving some of the lowest emissions in its class. It features a large loading chamber which can easily accomodate a full carcass or 350kg per batch of other waste. LOAD CAPACITY Inciner8 uses four main size guides within our comprehensive range to differentiate our models, from S to XL. This allows us to...

 Open the catalog to page 2
i8-500G General Waste Incinerator Datasheet-3

TECHNICAL BREAKDOWN Independent control of primary and secondary temperatures via the control panel. SECONDARY CHAMBER Retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C. CHIMNEY STACK Stainless steel stack for longevity. Fitted with a Velocity Cowl as standard. PRIMARY CHAMBER Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time. SAFE USE HANDLES Easy to open and close loading door. Designed to increase operator safety. COOL TOUCH CLADDING Steel cladding to reduce risk of infection and increase longevity of system....

 Open the catalog to page 3
i8-500G General Waste Incinerator Datasheet-4

TECHNICAL SPECIFICATION OPERATIONAL SPEC PHYSICAL SPEC Combustion Chamber Volume (m3) Fuel Consumption (Ltrs p/hour) Gas retention Time (Seconds) Loading Method Fuel Options Refractory Composition Electricity Supply Operating Footprint Control Panel (IP Rating) Cool Touch Cladding Heat Recovery Viewing Portal Auto Loader Compatible Remote Monitoring Recommended Operational Temperature *The above figures are guidelines ONLY. Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease of installation, maintenance...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.