TECHNICAL INTRODUCTION The flagship model within our general lineup is the i8-1000G. It took over three years to develop and is at the forefront of combustion technology, offering impressive burn rates and large batch sizes while still achieving some of the lowest emissions in its class. The i8-1000G can be customised with viewing windows, external cladding and automatic loading to provide an effective and sustainable waste disposal solution for many different types of industries with large volumes of waste such as RDF, SRF and MSW. It also has the benefit of being fitted with our smartpanel...
Open the catalog to page 2TECHNICAL BREAKDOWN Independent control of primary and secondary temperatures via the control panel. SECONDARY CHAMBER Retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C. CHIMNEY STACK Stainless steel stack for longevity. Fitted with a velocity cowl as standard. PRIMARY CHAMBER Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time. SAFE USE HANDLES Easy to open and close loading door. Designed to increase operator safety. COOL TOUCH CLADDING Steel cladding to reduce risk of infection and increase longevity of system....
Open the catalog to page 3TECHNICAL SPECIFICATION OPERATIONAL SPEC PHYSICAL SPEC Combustion Chamber Volume (m3) Fuel Consumption (Ltrs p/hour) Gas retention Time (Seconds) Loading Method Fuel Options Refractory Composition Electricity Supply Operating Footprint Control Panel (IP Rating) Cool Touch Cladding Heat Recovery Viewing Portal Auto Loader Compatible Remote Monitoring Recommended Operational Temperature *The above figures are guidelines ONLY. Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease of installation, maintenance...
Open the catalog to page 412 Pages
12 Pages