HVAC Brochure
12Pages

{{requestButtons}}

Catalog excerpts

HVAC Brochure - 1

AC Variable Speed Drives For HVAC Applications

Open the catalog to page 1
HVAC Brochure - 2

The IMO Jaguar VXH range can make a significant reduction in global energy usage Up to 50% of energy consumption in schools, hospitals, shopping centres, hotels and office buildings is related to air conditioning. The IMO Jaguar VXH series is a dedicated inverter for HVAC applications that offers functions and features designed to create the optimal environment for the people using the building whilst keeping the energy consumption in AHUs, water pumps, compressors, condensers, and others to a minimum. Equally at home as part of a BMS system or as a standalone solution the IMO Jaguar VXH...

Open the catalog to page 2
HVAC Brochure - 3

Optimum Control for HVAC Applications Air Handling Unit (AHU) Supply fan / Return fan The speed of supply and return fans can be adjusted to optimise performance according to pressure, discharge temperatures, room temperature, or other environmental conditions. The highest level of energy efficiency can be achieved by controlling the air flow based on the carbon dioxide level in the room. Chilled water pump The chilled water pump circulates the chilled water generated by the freezing machine to the air conditioner and fan coil. The pump speed is adjusted to optimum performance according to...

Open the catalog to page 3
HVAC Brochure - 4

User friendly, easy to see keypad The following values can be shown on the enlarged LCD display *User defined process value display options Multi-language function: 19 languages + user customized language Real time clock (RTC) is provided as standard Alarm function: • Alarm information with date and time • Previous 10 alarms are stored and displayed with date and time ^- Timer function: • Ability to set up to four timers per week • Ability to set up to 20 holidays per year • Daylight saving feature same schedule The operational schedule can be set using four independent timers when...

Open the catalog to page 4
HVAC Brochure - 5

Inverter output current Input power supply: 4:400V Protection structure: M:IP21 L:IP55 5. Cooling fan Easy replacement just by simply removing and attaching the part. Life expectancy can be increased by controlling ON and OFF. 1. User-friendly, easy to see dedicated keypad Multi-language supported, HELP function featured, unit setting with SV and PV values, data copy (three kinds), detachable and can be attached on the panel (using an optional cable) 4. Capacitor board Outputs the life prediction signal determining capacitor level drop and cumulative running hours. This allows the user to...

Open the catalog to page 5
HVAC Brochure - 6

Specific HVAC Functions Linearization function This function estimates the target pressure using the flow rate, which allows the estimated terminal pressure to be controlled. For an air-conditioning heat source system, the quantity of the cooling or heating water required fluctuates due to outside temperature or day/night requirements. Therefore, maintaining a constant water pressure may lead to unnecessarily high pressures on terminals at a low operating state and wasted energy at the pump. By controlling the pump, using a correlation of required pressure and the estimated terminal...

Open the catalog to page 6
HVAC Brochure - 7

Wet-bulb temperature estimation control This function is used for controlling cooling tower and fans. The wet-bulb temperature could be higher than the set temperature if the external air temperature is too high. In this case the water temperature would not be able to reach the set temperature so the fan keeps rotating at high speed and fails to deliver energy savings. Jaguar-VXH automatically estimates the wet-bulb temperature and controls the fan so that the cooling water is interlocked with the air temperature so as not to Filter clogging prevention function This function detects...

Open the catalog to page 7
HVAC Brochure - 8

Standard Specifications *1) Applicable standard motors are the case for IM0 4-pole standard motors *2) The rated capacity indicates the case of 440V ratings *3) Output voltage cannot exceed the power supply voltage *4) Interphase voltage unbalance ration [%] = (max. voltage [V] - min. voltage [V]/3 phase average voltage [V]x67 (see IEC61800-3). When unbalance ratio is between 2 - 3% please use optional AC reactor (ACR). *5) Average braking torque obtained by use of a motor. 9Varies with the efficiency of

Open the catalog to page 8
HVAC Brochure - 9

Outline drawing Power supply Applicable standard Inverter model

Open the catalog to page 9
HVAC Brochure - 10

Outline drawing Basic configuration diagram (Factory shipped condition: with SOURCE mode input and enable input function) MCCB Magnetic contactor Analog input Contact point output Multi-step frequfifKy selection iQ™ 1 steps) Mufti-step frequency selection (0~3steps) Self-hold selection Coast-to-stop command Alarm reset Frequency setting 2yfitquency setting 1 Local (keypad) instruction selection During operation Frequency (speed) agreement Frequency (speed) detection Motor overload prediction Common terminal (Shared between sink and source) frequency meter frequency meter Data send/receive

Open the catalog to page 10
HVAC Brochure - 11

Options Description Relay output interface card Relay output interface card Analogue input interface card Analogue current output interface card CC-Link communications card DeviceNet communications card PROFIBUS DP communications card CANopen communications card LonWorks communications card Ethernet communications card PT100 temperature sensor input card Battery From our market leading CUB, VXR, VXG, VXH and VXA range of drives with varying functionality and power, IMO has the right frequency inverter to meet the needs of your application, whatever it might be. From a simple small pump or...

Open the catalog to page 11
HVAC Brochure - 12

IMO Precision Controls Limited 1000 North Circular Road Staples Corner London NW2 7JP United Kingdom IMO Automazione Via Ponte alle Mosse, 61 50144 Firenze (FI) Italia Tel: +8000 452 6444 Fax: +8000 452 6445 Email: imo-it@imopc.it Web: www.imopc.it IMO Jeambrun Automation SAS Centre D’Affaires Rocroy 30, Rue de Rocroy 94100 Saint-Maur-Des-Fosses France IMO Canada Unit 32 - B-North 18 Strathearn Avenue, Brampton Ontario L6T 4Y2 Canada Tel: +8000 452 6444 Fax: +8000 452 6445 Email: imo-fr@imopc.fr Web: www.imopc.fr

Open the catalog to page 12

All IMO Precision Controls Limited catalogs and technical brochures

  1. Drive 2

    6 Pages

  2. VXA Brochure

    12 Pages

  3. Push Buttons

    32 Pages

  4. MCB Brochure

    8 Pages

  5. Din Terminals

    64 Pages

  6. Panel Products

    24 Pages

  7. Jaguar Drives

    20 Pages

  8. Terminal Block

    68 Pages

  9. Relays

    36 Pages

  10. Audible Devices

    126 Pages

  11. Solar Cube

    4 Pages

  12. BX series

    3 Pages

  13. XGB

    5 Pages

  14. IMO

    56 Pages