INTERNATIONAL STANDARDS
Open the catalog to page 1INTERPUMP Hypress 1SC INTERPUMP Hypress 2SC INTERPUMP Hypress R17 INTERPUMP Hypress FOUR SP Hypress UniLock Dimensions and general characteristics may be changed at any time, data contained here in are only for information purpose only and it does not enlarge, amend or imply any warranty other than provided by us with the product. Any use of the product not in conformance with our instructions may be dangerous.
Open the catalog to page 2Hypress EASY K 1SCTFA201KI APPLICABLE SPECIFICATIONS Compact hose according to EN 857 ISO 11237. NO-SKIVE solution. Smooth cover. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 high tensile steel wire braids. Coverage: Smooth synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C, from -40 to +70° C for water based fluids, from 0 to +70°C water. Marking: Ink-jet
Open the catalog to page 3Hypress EASY K 2SCB TFA202KI APPLICATIONS APPLICABLE SPECIFICATIONS EN 857 2SC - ISO 11237 Compact hose according to EN 857 ISO 11237. NO-SKIVE solution. Smooth cover. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Smooth synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C, from -40 to +70° C for water based fluids, from 0 to +70°C water. Marking: Ink-jet
Open the catalog to page 4INTERPUMP Hypress One 1SN APPLICABLE SPECIFICATIONS TFD2012 NO-SKIVE hose. Exceed Burst specification. impulse tested up to double requirements. Reduced bending radius. Lightness. Smooth cover up to 1” Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 steel wire braid. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C (intermittent 120°C), from -40 to +70° C for water based...
Open the catalog to page 5INTERPUMP Hypress Two 2SNTFD2022 APPLICATIONS APPLICABLE SPECIFICATIONS NO-SKIVE hose. Exceed Burst specification. impulse tested up to double requirements. Reduced bending radius. Lightness. Smooth cover up to 1” Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C (intermittent 120°C), from -40...
Open the catalog to page 6APPLICATIONS : APPROVALS:ABS, CCSAPPLICABLE SPECIFICATIONSExceed EN 857 1SC - ISO 11237 INTERPUMP Hypress 1SCTFE201K NO-SKIVE hose. Exceed Burst specification. Impulse tested up to double requirements. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 steel wire braid. Coverage: Smooth synthetic rubber, resistant to oils, fuelsa and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +120°C (intermittent 135°C), from -40 to +70° C for water based fluids,...
Open the catalog to page 7APPLICATIONSAPPROVALS :MED, BV, LLOYD’S, ABS, NKK, KR, DNV, CCSAPPLICABLE SPECIFICATIONSExceed EN 857 2SC - SAE 100 R16 - ISO 11237 Compact hose with Low bend radius (R16). NO-SKIVE solution. Exceed standard Burst requirements. impulse tested up to double requirements. Certifications valid only for MSHA cover. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Smooth synthetic rubber, resistant to oils, fuelsa and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based,...
Open the catalog to page 8APPLICATIONS :APPLICABLE SPECIFICATIONS SAE 100R17 - SAE J 517 - ISO 11237 R17 Isobaric pressure rating 210 bar/3000 psi. No skive compact hose. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: High tensile steel. 1 braid up to size 1/2", 2 braids from size 5/8" onwards. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C (intermittent 120°C), from -40 to +70° C for water based...
Open the catalog to page 9gUSEGi! APPLICABLE SPECIFICATIONS 4 high tensile spiral high flexibility. Performance according EN856 - ISO 3862 4SP. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 4 steel wire spirals. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C (intermittent 120°C), from -40 to +70° C for water based fluids, from 0 to +70°C water. Product number Available with MSHA and Mega cover....
Open the catalog to page 10APPLICATIONS :APPROVALS:MED, DNV - GL, BV, MSHAAPPLICABLE SPECIFICATIONSEN 856 4SP - ISO 3862 4SP 4 high tensile spiral high flexibility. MSHA cover. Exceeding bust requirements. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 4 steel wire spirals. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Hydraulic fluids petroleum based (mineral oils), glicol-water based, water, lubricants. working temperature: from -40 to + 100° C petroleum based fluids (Intermittent 120°C), from -40 to...
Open the catalog to page 11Hypress UniLockB TFS0006I APPLICATIC APPLICABLE SPECIFICATIONSSAE100R6 - EN 8541TE UniLock fittings series, easy assembly, no tools or clamps required. Safety factor 4:1. Do not use for compressed air braking systems and circuits subject to high pressure impulses. Inner tube: Oil resistant synthetic rubber. Reinforcement: 1 textile braid. Coverage: Synthetic rubber resistant to oils, fuels and atmospheric conditions. Recommended fluids: Hydraulic fluids petroleum based (mineral oils), glicol-water based, water, lubricants. working temperature: from -40 to + 100° C petroleum based fluids, from...