1. Catalogs
  2. IMM Hydraulics
  3. HIGH PERFORMANCE
video corpo

HIGH PERFORMANCE
1 /15Pages

HIGH PERFORMANCE

HIGH PERFORMANCE
1 /15Pages

Catalog excerpts

HIGH PERFORMANCE-2

INTERPUMP Pilot Plus 150 INTERPUMP TREEATHLON INTERPUMP HyGreen R13 INTERPUMP HyGreen R15 Dimensions and general characteristics may be changed at any time, data contained here in are only for information purpose only and it does not enlarge, amend or imply any warranty other than provided by us with the product. Any use of the product not in conformance with our instructions may be dangerous.

 Open the catalog to page 2
HIGH PERFORMANCE-3

INTERPUMP APPLICATIONS : HyCelsius One 1SN TFDH012B Wide range temperature resistance. Hoses are not designed and not approved for "air brake” applications on railway and/or mobile equipment. Do not use with compressor. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 steel wire braid. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +135°C (intermittent 140°C). Marking: Available...

 Open the catalog to page 3
HIGH PERFORMANCE-4

INTERPUMP HyCelsius Two 2SNTFDH022B APPLICATIONS : IfflHEIfl APPLICABLE SPECIFICATIONS Wide range temperature resistance. Hoses are not designed and not approved for "air brake” applications on railway and/or mobile equipment. Do not use with compressor. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40...

 Open the catalog to page 4
HIGH PERFORMANCE-5

APPLICATIONS :APPLICABLE SPECIFICATIONS EN 853 1SN - SAE 100R1AT Suitable for very cold enviroments. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 steel wire braid. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C, min. external temperature -50°C. Marking: Available only "embossed"

 Open the catalog to page 5
HIGH PERFORMANCE-6

Suitable for very cold enviroments. APPLICABLE SPECIFICATIONS Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +100°C, min. external temperature -50°C. Product number Marking: Available only "embossed"

 Open the catalog to page 6
HIGH PERFORMANCE-7

APPLICATIONS : INTERPUMP PilotFlex 120TFE2PF2 APPLICABLE SPECIFICATIONS IMM specification Smooth cover with high abrasion resistance. User friendly and Easy to Handle configuration. Extreme compactness and flexibility with the lowest bend radius. Tested up 1.000.000 cycles. Safety factor 4:1. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 high tensile steel wire braid. Coverage: Smooth synthetic rubber, resistant to oils, fuelsa and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants....

 Open the catalog to page 7
HIGH PERFORMANCE-8

INTERPUMP Pilot Plus 150 TFE2P15 APPLICATIONSAPPLICABLE SPECIFICATIONS IMM specification Lightweight. Compact design. High flexibility. Tested up 1.000.000 impulse cycles at rated working pressure. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 high tensile steel wire braid. Coverage: Smooth synthetic rubber, resistant to oils, fuelsa and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +120°C (intermittent 135°C), from -40 to +70° C for water based...

 Open the catalog to page 8
HIGH PERFORMANCE-9

APPLICATIONS :APPROVALS :MED, RINA, BV, LLOYD’S, NKK, KR, DNVAPPLICABLE SPECIFICATIONSexceed EN 857 1SC- ISO 11237 1SC No-SKIVE hose. High abrasion resistance. Pressure rating exceeding standards. Easy to install. SMOOTH COVER up to 1”. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 1 high tensile steel wire braids. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +120°C (intermittent...

 Open the catalog to page 9
HIGH PERFORMANCE-10

APPLICATIONS :APPROVALS :MED, RINA, BV, LLOYD’S, ABS, NKK, KR, DNV, CCSAPPLICABLE SPECIFICATIONSexceed EN 857 2SC - ISO 11237 No-SKIVE hose. High abrasion resistance. Pressure rating exceeding standards. Tested up to 1.000.000 cycles up to 1". Easy to install. SMOOTH COVER up to 1". Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Anti-abrasive syntetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working...

 Open the catalog to page 10
HIGH PERFORMANCE-11

APPLICATIONS :APPLICABLE SPECIFICATIONS IMM - exceed EN 857 2SC - ISO 11237 2SC NO-SKIVE hose. Exceed EN specification. Impulse tested up to 1.000.000 cycles. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 2 high tensile steel wire braids. Coverage: Smooth synthetic rubber, resistant to oils, fuelsa and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to +120°C (intermittent 135°C), from -40 to +70° C for water based fluids, from 0 to +70°C water. Product...

 Open the catalog to page 11
HIGH PERFORMANCE-12

INTERPUMP TREEATHLONAPPLICATIONS : APPLICABLE SPECIFICATIONS IMM SPECS Compact hose. NO-SKIVE construction. NBR tube compound compatible with several fluids. Approved up to 500.000 impulse cycles. Tested at 120% Max WP. Inner tube: Synthetic rubber, extruded whole without joints, of uniform thickness. Reinforcement: 3 high tensile steel wire braids. Coverage: Anti-abrasive synthetic rubber, resistant to oils, fuels and atmospheric conditions. Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants. working temperature: from -40 to + 100° C petroleum based fluids...

 Open the catalog to page 12

All IMM Hydraulics catalogs and technical brochures

  1. Skiving

    3  Pages

  2. Cutting

    7  Pages

  3. Crimping

    25  Pages

  4. Adapters ORFS

    43  Pages

  5. Standard Tail

    85  Pages

  6. Interlock Tail

    22  Pages

  7. Thermoplastic

    9  Pages

  8. PTFE

    4  Pages

  9. HYSOBARIC LINE

    10  Pages

  10. Machines

    59  Pages

  11. One Piece

    106  Pages

  12. Fittings

    162  Pages

  13. Quick Couplings

    52  Pages

  14. MGQUIX

    40  Pages

  15. N Tail

    27  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.