A Group brand Q lecjlcind STATIC I ENERGY METERS FOR SINGLE AND THREE PHASE NETWORK

Open the catalog to page 1
STATIC ENERGY METERS CONTO - 2

STATIC ENERGY METERS CONTO NEW New Conto D6 Static meter for direct connection up to 125A, also available with MID certification. Energy meters one-way multi measure, also suitable for tax purposes applications. The LCD display, show active energy consumption (kWh) Class 1 EN/IEC 62053-21 or EN 50470 certified class B MID, and reactive (kvarh) Class 2 EN/IEC 62053-23 addition to the main electrical parameters.

Open the catalog to page 2
STATIC ENERGY METERS CONTO - 3

MID certification Conto static meter guarantees accuracy and reliability of measurement, and thanks to european directive homologation 2004/32/CE, can be used for tax purposes. The static meter are equipped by tamper-proof components to prevent fraud or access to some functions (no reset). Direct measurement up to 125 A Direct measurement for currents up to 125 A, singlephase and three-phase, indirect measurement via current transformers. Energy management Thanks to models with pulse outputs or RS485 communications, ModBus RTU or M-Bus, energy meters are easily integrated into main system...

Open the catalog to page 3
STATIC ENERGY METERS CONTO - 4

kVT/ kCT transformations ratio to CT and VT defined as the mathematical ratio between the primary and secondary value. Example: kVT of a transformer 1000/100V = 1000:100 = 10 kCT of a transformer 800/5A = 800:5 = 160 With interface (see general catalogue "software and interfaces")

Open the catalog to page 4
STATIC ENERGY METERS CONTO - 5

Static Energy MetersSelection table CONTO D1 LV

Open the catalog to page 5
STATIC ENERGY METERS CONTO - 6

Static meter 45 A direct connection Active energy kWh EN50470 cl. B Static Meter with MID certification Direct connection for single-phase network. It makes available active energy counting of the pulse output to integration of consumption supervision systems. Functions • Total Active Energy Cat. Nos. Conto D1 MID Network Output

Open the catalog to page 6
STATIC ENERGY METERS CONTO - 7

Static Energy Meters ® Static meter 63 A direct connection Output RS485 ModBus RTU Pulse Active energy kWh EN50470 cl. B Static Meter with MID certification Direct connection for single-phase network. It makes available active energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Total active energy (MID) • Partial active energy • Current / Voltage • Active...

Open the catalog to page 7
STATIC ENERGY METERS CONTO - 8

Static meter 63 A direct connection Static Meter with MID certification Direct connection for three-phase network, 3 or 4-wires. It makes available active or reactive energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU or M-Bus, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Active energy (MID) • Reactive energy • Partial positive, active and reactive energy • Current / Voltage • Frequency • Power factor •...

Open the catalog to page 8
STATIC ENERGY METERS CONTO - 9

Static Energy Meters ®Static meter by CT Cat. Nos. CE4DMID01 CE4DMID0M Static Meter with MID certification Static meter by CT for single and three-phase network, 3 or 4-wires. It makes available active or reactive energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Active and Reactive energy primary side (external CT and/or VT) • Active energy to the terminals...

Open the catalog to page 9
STATIC ENERGY METERS CONTO - 10

Static meter 125 A direct connection Output Pulse Pulse + RS485 ModBus RTU/TCP Direct connection for three-phase network, 4-wires. It makes available active or reactive energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Total / Partial Active Energy or Active Energy Tariff 1 and 2 • Total / Partial Reactive Energy or reactive Energy Tariff 1 and 2 •...

Open the catalog to page 10
STATIC ENERGY METERS CONTO - 11

Static Energy Meters Static meter 32/45 A direct connection

Open the catalog to page 11
STATIC ENERGY METERS CONTO - 12

Direct connection for single-phase network. Functions • Active energy Cat. Nos. Conto D2-b Network CE21175A0 1Ph+N Active energy kWh EN/IEC 62053-21 cl. 1 *For switchboard thermal calculation ■ Wiring diagrams LINE

Open the catalog to page 12
STATIC ENERGY METERS CONTO - 13

Static Energy Meters Static meter 63 A direct connection Active energy kWh EN/IEC 62053-21 cl. 1 Direct connection for single-phase network. It makes available active energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Total active energy • Partial active energy • Current / Voltage • Active power • Frequency • Power factor • Run hour meter (count start with...

Open the catalog to page 13
STATIC ENERGY METERS CONTO - 14

Static meter 63 A direct connection Output RS485 ModBus RTU/TCP Pulse RS485 ModBus RTU/TCP M-Bus Pulse output RS485 ModBus RTU/TCP Direct connection for three-phase network, 3 or 4-wires and for singlephase 3 inputs. It makes available active or reactive energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU or M-Bus, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Total active and reactive energy, active and...

Open the catalog to page 14
STATIC ENERGY METERS CONTO - 15

Static Energy Meters Static meter 125 A direct connection Output Pulse Pulse + RS485 ModBus RTU Direct connection for three-phase network, 4-wires. It makes available active or reactive energy counting of the pulse output to integration of consumption supervision systems. For supervision systems, through the model with output RS485 communication Modbus RTU, you can transmitted on the network main electrical parameters in addition to the energy consumption. Functions • Total / Partial Active Energy or Active Energy Tariff 1 and 2 • Total / Partial Reactive Energy or reactive Energy Tariff 1...

Open the catalog to page 15

All IME Spa catalogs and technical brochures

  1. NEMO SX

    24 Pages

  2. EASYCONNECT

    20 Pages

  3. CONTO D6-Pd

    2 Pages

  4. Accessories

    2 Pages

  5. Nemo 72 Le

    9 Pages

  6. Nemo 96-b

    6 Pages

  7. Nemo D4-L

    7 Pages

  8. BTV10

    4 Pages

  9. BTV100

    4 Pages

  10. Multifunction

    12 Pages

  11. Transducers

    14 Pages

Archived catalogs

  1. Product guide

    274 Pages