Overview: The document provides comprehensive technical specifications and ordering information for various electrical devices, including communication and differential relay devices, transducers, signal separators, current transformers, digital meters, and other electrical components. It covers type conversion, energy counting, control and supervision, differential protection systems, and more.
Type Conversion and Communication: Devices for converting RS485 to Ethernet, RS485 to RS232, and RS485 to Profibus are detailed. Key specifications include auxiliary supply options (AC: 80-270V, DC: 100-300V), dimensions (2 or 3 module DIN), and a maximum Ethernet baud rate of 100Mb/s.
Energy Counting and Control: The CONTO software is for simple energy counting, while MIDAs Evo offers advanced network monitoring for up to 1020 devices, with features like data acquisition and alarm monitoring. It supports multiple operating systems and languages.
Differential Relays: Models such as Delta D2-L, Delta D2-s, Delta D4-s, and Delta D4-I are described, focusing on auxiliary supply options, relay outputs, reset methods, and dimensions. Features include harmonic filtering and LED displays.
Toroids and Accessories: Lists closed-core and open-core toroids for differential relays, with diameters from 28mm to 300mm, and summation toroids with ratios up to 400/5A.
Ordering Information: Each product section includes ordering codes, auxiliary supply options, and stock availability, with technical notes for installation and operation guidance.
Transducers and Signal Separators: Specifications include auxiliary supplies, input/output ranges, response times, and accuracy levels. Models like Tema SG, Tema DC, and Tema I are detailed with specific configurations.
Current Transformers and Digital Meters: Models such as HT35A, HT80A, and digital meters like DGM D4 are described, with specifications on dimensions, input/output configurations, and auxiliary supply options.
Electrical Measurement Equipment: Includes ammeters, voltmeters, frequency meters, and more, with features like moving coil mechanisms and accuracy classes from 0.5 to 1.5. Protection ratings include IP52 and IP54.
Procedures and Norms: Ordering codes and customization instructions are provided, with norms ensuring vibration-proof design and specified frequency ranges.
Recommendations: Guidance on selecting models based on application requirements and environmental conditions is provided.
Key Data from Tables: Includes ordering codes, dimensions, and connection types for various configurations.
Critical Information: Emphasizes compatibility with existing systems, correct ordering code formats, and adherence to accuracy and protection standards.
See more

Catalog excerpts

Product guide-1

Istnimenti Misure Elettriche SpA RODUCT GUIDE

 Open the catalog to page 1
Product guide-4

Selection guide Overview of products by family PDF downloadable Dynamic catalogue Search of products by technical features Technical documentation Technical notes and user’s manual PDF downloadable Sales organisation Agent and distributor contacts in Italy and all over the world Events Dates and exhibition positions, meetings and trade fairs attended by us News All new products recently introduced

 Open the catalog to page 4
Product guide-5

Work with us If you wish to join our staff see our job opportunities or insert your application www.imeitaly.com All the replies that you want. Whenever you want

 Open the catalog to page 5
Product guide-6

Time sensors They detect the signals, where rise Low voltage transformers Ring transformers for differential relays Insulation transformers Shunts Transformers with built-in transducer Control and Supervision They analyze the data and interact Management software to monitor energy Measuring single quantities They measure an electrical or physical quantity Analogue indicators Digital indicators Luminous bar indicators Transducers Measuring and Monitoring They measure and report specific involved conditions Analogue indicators with alarms Digital indicators with alarms Multifunction indicators...

 Open the catalog to page 6
Product guide-7

Protection They report anomalies in the system, protecting it Differential relays Insulation relays Measuring relays Energy counting They quantify the energy consumption Energy meters Multifunction meters Communication They communicate the measurements carried at a distance Interface different ways of communication Energy meters Multifunction meters Digital meters Interfaces Multimetering They measure and display simultaneously more quantities Multifunction meters

 Open the catalog to page 7
Product guide-8

Multifunction Nemo 96 HD/HD+ M-Bus / BACnet / Ethernet / Temperature Pt100 modules Nemo 96 HDL l.v. ac networks Nemo D4-Dc dc networks Nemo D4-L+ BACnet communication protocol Software interface Conto imp pulse concentrator, 12 energy, gas, water inputs or ES GME card Energy meters Conto D1 single-phase active energy Conto D2 single-phase active energy with RS485 communication single-phase active energy MID Conto D4-Pt/Pd M-Bus communication protocol three-phase active energy MID

 Open the catalog to page 8
Product guide-9

News Differential relays Delta D4-I public lighting / traffic light systems Delta 72F - Delta 96F industrial applications with distorted currents Delta 48-s 2 output relays Delta TCS release circuit breakers test Measuring relay Beep management of single-phase loads up to 6KW Current transformers with built-in transducers HT35Bm - HT35Bs Dc network / selectable current 10...100A

 Open the catalog to page 9
Product guide-10

PRODUCT GUIDE IME S.p.A. reserves the right, to modify the technical characteristics without notice

 Open the catalog to page 10
Product guide-14

Ordering codes see page: single phase, 3-phase 3/4 wires unbalanced load l.v. and M.V. single phase, 3-phase 3/4 wires unbalanced load l.v. Voltage, current, frequency Neutral current Average currents and max. values Harmonic distortion voltage, current Average power and max. value Power factor Active, reactive, apparent power Phase active and reactive power Active energy Isolated input Non-isolated input Partial active energy Reactive energy Phase sequence Pulse energy BACnet Input current Input voltage Technical note Price Extra price d.c. auxiliary supply and 48Va.c. Primary currents selectable...

 Open the catalog to page 14
Product guide-15

Ordering codes see page: single phase/3-phase 4 wires unbalanced load l.v. 3-phase 3/4 wires unbalanced load l.v. Non-isolated input Voltage, current, frequency Neutral current Average currents ad max. values Active, reactive, apparent power Phase active and reactive power Average power and max. value Power factor single phase, 3-phase 3/4 wires unbalanced load l.v. Active energy Reactive energy Current total harmonic distortion Phase sequence 2 allarm relays Pulse active energy RS485 communication Input current Input voltage (phase-phase) 1 - 5A from CT 80…500V direct or from VT 1...9999 Technical...

 Open the catalog to page 15
Product guide-16

Model Codes Ordering codes see page: Positive energy Negative energy Positive and negative ampere-hour Imput voltage Voltage, current, power Average power and max. value Pulse energy Direct current input Current input from shunt Technical note Extra price d.c. auxiliary supply and 48Va.c. external interface (see section 03) overall dimensions page 11

 Open the catalog to page 16
Product guide-17

Codes Ordering codes see page: 09 single phase, 3-phase 3/4 wires bal./unbal. load l.v./M.V./H.T. single phase, 3-phase 3/4 wires bal./unbal. load l.v. Non-isolated input Isolated input Phase and linked voltage min. and max. instantaneous value Harmonic distortion voltage, current Phase and neutral current1 Phase sequence Neutral current measure2 Average current and max. value Phase and three-phase power active, reactive, apparent Average power and max. value active, reactive, apparent Phase and three-phase power factor Frequency, hourmeter Active energy positive and negative Reactive energy...

 Open the catalog to page 17
Product guide-18

Model Codes Ordering codes see page: Interface Type Standard Protocol Maximun baud rate Technical note Model Codes Ordering codes see page: Interface Type Inputs channels energy pulse - Outputs channels Output Technical note overall dimensions page 11

 Open the catalog to page 18
Product guide-19

Ordering codes see page: Digital inputs + alarms Digital inputs + alarms SPST contact SPST relays SPST relays Technical note 2 energy pulse output Neutral current Profibus communication LonWorks communication I / O 2 inputs SPST - 2 outputs SPST I / O 2 inputs 12 - 24Vd.c. - 2 outputs SPST RS485 - Energy value storage M-Bus communication Ethernet communication On the table it is shown the Firmware version of the meter which supports the function of the extra module. By using an IF96001 (RS485) or IF96002 (RS232) or IF96015 (Ethernet) communication module it is possible to update the Firmware...

 Open the catalog to page 19
Product guide-20

Multifunction for l.v. network, single-phase or 3-phase Ordering code Auxiliary supply Package including n. 1 Nemo D4-b multifunction meter + n. 3 TAIBB current transformers Ordering code Auxiliary supply Auxiliary supply Multifunction for l.v. / M.V. network, single-phase or 3-phase Ordering code Auxiliary supply Multifunction for l.v. network, single-phase or 3-phase Ordering code RS4851 RS485 comunication Jbus /Modbus protocol BACNET1 RS485 comunication BACNET protocol Ordering code Auxiliary supply

 Open the catalog to page 20
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.