1. Catalogs
  2. IME Spa
  3. Analogue meters

Analogue meters
1 /50Pages

Analogue meters

Analogue meters
1 /50Pages

Catalog excerpts

Analogue meters-2

Ordering code Ordering code Ordering code Other executions available on all models: 2In overscale Replace the 6 digit of the code with “5” Replace the 6a digit of the code with “2” Replace the 5a digit of the code with “1” overall dimensions page 50

 Open the catalog to page 2
Analogue meters-3

Alternating current ammeters RQ Ordering code Ordering code Ordering code Other executions available on all models: 2In overscale Replace the 6a digit of the code with “2” Replace the 6a digit of the code with “5” features moving iron equipment, 90° scale width, accuracy class 1,5 working frequency 45...65Hz, IP52 front protection, IP20 terminal protection with teminal cover available options ordering code vibrationproff - tropicalized IP54 vibrationproff front protection overall dimensions page 50

 Open the catalog to page 3
Analogue meters-4

Alternating voltage voltmeters RQ Ordering code Ordering code Ordering code Ordering code Ordering code Ordering code Note: data to be shown in addition to ordering code A scale and VT ratio (the scale value must correspond to the result between the chosen range value and the VT ratio) ex.: range 120V, VT ratio 500/100V scale value = 120x500:100=600V B scale and VT ratio features and available options page 03 overall dimensions page 50

 Open the catalog to page 4
Analogue meters-5

Direct current ammeters RQ direct, lateral zero (0...In) direct, lateral zero (0...In) direct, lateral zero (0...In) Ordering code Ordering code Ordering code Other executions available on all models: Central zero (-In...0...+In) Replace the 5a digit of the code with “1” for µA range Replace the 5 digit of the code with “9” for A range features and available options page 07 overall dimensions page 50

 Open the catalog to page 5
Analogue meters-6

on shunt with 60mV c.d.t. lateral zero (0...In) on shunt with 60mV c.d.t. lateral zero (0...In) on shunt with 60mV c.d.t. lateral zero (0...In) Ordering code Ordering code Ordering code Other executions available on all models: Central zero (-In...0...+In) Replace the 5a digit of the code with “1” overall dimensions page 50

 Open the catalog to page 6
Analogue meters-7

Direct current ammeters RQ Model Connection Dimensions on shunt with 60mV c.d.t. deplaced zero on shunt with 60mV c.d.t. deplaced zero on shunt with 60mV c.d.t. deplaced zero 48x48x75 mm Ordering code Model Input Dimensions Range 4...20mA (mechanic. supp.) 0...4...20mA (live zero) from transducers or sensor with 4...20mA output from transducers or sensor with 4...20mA output from transducers or sensor with 4...20mA output 48x48x75 mm Ordering code Ordering code Ordering code Model Input Dimensions Range from transducers or sensor, lateral zero (0...In) from transducers or sensor, lateral zero...

 Open the catalog to page 7
Analogue meters-8

Direct voltage voltmeters RQ direct, lateral zero (0...Un) direct, lateral zero (0...Un) direct, lateral zero (0...Un) Ordering code Ordering code Ordering code Other executions available on all models: Central zero (-Un...0...+Un) Replace the 5a digit of the code with “5” from transducers or shunt lateral zero (0...Un) from transducers or shunt lateral zero (0...Un) from transducers or shunt lateral zero (0...Un) Ordering code Ordering code Ordering code Other executions available on all models: Central zero (-Un...0...+Un) Replace the 5a digit of the code with “3” for mV range Replace the 5a...

 Open the catalog to page 8
Analogue meters-9

Maximum demand ammeters RQ on CT/5A scale 0...1,2In delay time 15 min. on CT/5A scale 0...1,2In delay time 15 min. on CT/5A scale 0...1,2In delay time 15 min. Ordering code Ordering code features and available options page 11 overall dimensions page 50 Ordering code

 Open the catalog to page 9
Analogue meters-10

on CT/5A thermal scale 0...1,2In, moving-iron scale 0...In delay time 15 min. on CT/5A thermal scale 0...1,2In, moving-iron scale 0...In delay time 15 min. Ordering code Ordering code overall dimensions page 50

 Open the catalog to page 10
Analogue meters-11

Thermal and moving iron ammeters RQ features Thermal ammeters thermal equipment, 90° scale width, accuracy class 3 working frequency 45...65Hz, IP52 front protection, IP00 terminal protection features Thermal and moving iron ammeters thermal and moving-iron equipment, 90° scale width, accuracy class: 3 (thermal) - 1,5 (moving-iron) working frequency 45...65Hz, IP52 front protection, IP20 terminal protection with terminal cover available options ordering code

 Open the catalog to page 11
Analogue meters-12

Ordering code Ordering code Ordering code Ordering code Ordering code Ordering code Ordering code Ordering code Ordering code features moving coil equipment with built-in frequency accessory, 90° scale width, vibrationproof standard accuracy class 0,5 (45...55Hz or 55...65Hz), accuracy class 1 (45...65Hz), IP52 front protection, IP20 terminal protection with terminal cover available options ordering code overall dimensions page 50

 Open the catalog to page 12
Analogue meters-13

Wattmeters with separate accessory RQ 0...1mA (lateral zero) ±1mA (central zero) -…0…+1mA (desplaced zero) Ordering code Ordering code Ordering code Three-phase 3 wire balanced load Three-phase 4 wire balanced load Ordering code Ordering code Ordering code Three-phase 3 wire unbalanced load Three-phase 4 wire unbalanced load Ordering code Ordering code Note: data to be shown in addition to ordering code A W or kW or MW beginning and full scale value B CT ratio, VT ratio if scheduled, the power value corresponding to output that shall be included between the 50% and 120% of Pn rated power single-phase...

 Open the catalog to page 13
Analogue meters-14

Varmeters with separate accessory RQ 0...1mA (lateral zero) ±1mA (central zero) -…0…+1mA (desplaced zero) Ordering code Ordering code Ordering code Three-phase 3 wire balanced load Three-phase 3 wire unbalanced load Ordering code Ordering code Three-phase 4 wire balanced load Three-phase 4 wire unbalanced load Ordering code Ordering code Note: data to be shown in addition to ordering code, available options and overprice see page 15 A var or kvar or Mvar beginning and full scale value B CT ratio, VT ratio if scheduled, the power value corresponding to output that shall be included between the...

 Open the catalog to page 14
Analogue meters-15

P.F. meters with separate accessory RQ Ordering code Ordering code Ordering code Dimensions Connection on line 4 module DIN Single-phase or Three-phase 4 wire balanced load 4 module DIN Three-phase 3 wire balanced load Ordering code Ordering code 400V 1A ind 0,5...1...0,5 cap 400V 5A ind 0,5...1...0,5 cap 415V 1A ind 0,5...1...0,5 cap 415V 5A ind 0,5...1...0,5 cap Note: data to be shown in addition to ordering code A scale ind 0,5...1...0,5 cap features RQ - moving coil equipment, 90° scale width, vibrationproof standard, accuracy class 1,5, IP52 front protection, IP20 terminal protection with...

 Open the catalog to page 15

Archived catalogs

  1. Product guide

    274  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.