HASO R.FLEX
4Pages

{{requestButtons}}

Catalog excerpts

HASO R.FLEX - 1

METROLOGY TOOL FOR LARGE OPTICS LARGE DYNAMIC AND HIGH ACCURACY The most practical and cost effective metrology tool for characterizing optical components such as large concave mirrors, lenses, complex optical systems, and beam expanders A UNIQUE SET OF ADVANTAGES Standard accuracy of λ/100 rms and λ /200 rms in double pass configurations Patented measurement technology of phase and intensity simultaneously and independently, and also large dynamic Collimated exit beam or divergent exit beam with different focusing modules from F/1 to F/16 Allows inspection with a desired wavelength Insensitivity to vibrations and atmospheric turbulences Dismountable wavefront sensor for using as a stand-alone unit Very low pupil distortion <3% Numerous accessories (translation stages, reference mirrors, diode lasers…) Delivered with WaveView metrology software Contact us for more details: contact@imagine-optic.com or +33 (0) 1 64 86 15 6

Open the catalog to page 1
HASO R.FLEX - 2

Examples of measurement configuration Measuring large concave mirrors Characterizing complex optical systems HASO R-Flex has been optimized using proprietary designs that enable manufacturers to accurately measure large uncoated concave mirrors by positioning the unit to measure at the center of curvature. Complex systems such as telescopes and collimators can be readily characterized by HASO R-Flex. The best focus point can be found using the wavefront error whereas, if the focus point is defined mechanically, optics can be aligned for that point. Measuring lenses on-axis Characterizing...

Open the catalog to page 2
HASO R.FLEX - 3

Sampling points Focusing Modules Pupil distorsion allows pupil imaging on MOD32-1 and MOD32-2 Sampling points Focusing Modules Pupil distorsion allows pupil imaging on MOD50-1 and MOD50-2 Sampling points Pupil imaging Focusing Modules (1) can be divided by 2 if the optical system under test is characterized by double-pass method (2) focal length of the module (3) WFE is the wavefront error at the output of the module for the largest included round pupil. (4) distance between the focalization point and the first optics (alignement holes must be removed) (5) YES means that the microlenses are...

Open the catalog to page 3
HASO R.FLEX - 4

Accessories Translation stage Our ΘXΘY rotation stage for angular alignment or 5-axis stage that provides 2-way rotation about X and Y axes as well as 3-way translation along the X, Y and Z axes is the perfect complement to HASO R-Flex. Software add-on HASO R-Flex is delivered with WaveView software. We provide optional software modules including MTF (Modulation Transfer Function) and PSF (Point Spread Function) that enable you to increase HASO R-Flex’s functionality. Reference mirror To complete your metrology system, we can provide a spherical reference mirror (Ø20mm useful pupil, < 10 nm...

Open the catalog to page 4