1. Catalogs
  2. IMADA
  3. Torque-Angle Measurement Unit TAA series

Torque-Angle Measurement Unit TAA series
1 /10Pages

Torque-Angle Measurement Unit TAA series

Torque-Angle Measurement Unit TAA series
1 /10Pages

Catalog excerpts

Torque-Angle Measurement Unit TAA series-1

Torque-Angle Measurement System TAA series - Measurement unit to analyze Torque (Rotating/Twisting force) -Angle relationships - Simple and accurate Torque-Angle measurement with high repeatability - Drawing and analyzing graphs with PC, simple real time operations - Desktop and handheld types available to meet your measurement needs Handheld type TAA-HTG series Space-saving Desktop type TAA-ACMTS-TB series TAA series is a measurement unit which can be used to measure and analyze Torque-Angle relationships. The high-speed sampling rate of 2000 Hz provides highly repeatable measurement results and draws smooth graph of torque-angle curves in real time. It is ideal for product quality control, operability, usability, physical characteristics, and functional evaluation.

 Open the catalog to page 1
Torque-Angle Measurement Unit TAA series-2

Torque-Angle Measurement System TAA series TAA-ACMTS-TB series Product Configuration 1. Screw Cap Torque Tester: DTXA series Measurement for rotating and twisting forces. Easily detachable for repair or calibration requirements. 2. Advanced Type Motorized Torque Stand: ACMTS-10N The upper attachment rotates at the set speed. Possible settings of the operations by the torque value and angle. Connecting DTXA and ACMTS-10N for control. 4. Software: Force Recorder Professional Real time Torque and Angle graphing Upper chuck MT-TB + Lower table DT-TB Attachments are interchangeable according to the...

 Open the catalog to page 2
Torque-Angle Measurement Unit TAA series-3

IMADA CO., LTD.Torque-Angle Measurement System TAA series[TAA-ACMTS-TB series model list] Model11 * The accommodate sample diameter depends on the selected attachment. Please refer to the specification sheet “Attachments for DTXS/DTXA series” and “Attachments for ACMTS/MTS series” in our website for details. *1 ( ): Required capacity to be selected. *2 Customized torque stand according to the sample height is available. *3 Please contact us to purchase the unit in combination with DTXA with a capacity of 0.5N-m (50N-cm). The capacity of the entire TAA-ACMTS-TB unit is limited by the capacity...

 Open the catalog to page 3
Torque-Angle Measurement Unit TAA series-4

IMADA CO., LTD.Torque-Angle Measurement System TAA series[Software operating environment] Operating environment [Downloadable Graphing Software Option] Downloadable Torque-Angle (Force-Displacement) Graphing Software A software for graphing torque-time / torque-angle - High sampling rate of max. 2000Hz enables accurate graphing. - Test condition presets: for effective recording / analysis of measurement results. - Data editing: overlaying up to 10 graphs, etc., for results editing / analysis. - Add Images / Comments function: useful for recording measurement data details. - The Print Command...

 Open the catalog to page 4
Torque-Angle Measurement Unit TAA series-5

IMADA CO., LTD. Torque-Angle Measurement System TAA series [Related Products TAA-ACMTS-TB series] For upper part Small chuck MT-ST Designed for small samples Sample diameter: φ7-50mm Capacity: 5N-m Selectable pin from standard, notch and long Ideal for gripping columnar samples Large: φ1.2-13mm Standard: φ0.5-6.5mm Small: φ0.5-4mm *1 The Fixing Pin for Standard Chuck MT-TB. Suitable for holding nozzle caps, etc. since its long shaft allows the pin knob to avoid obstacles and to clump the sample properly. For lower part Small table DT-ST Designed for small samples Sample diameter: φ7-50mm Capacity:...

 Open the catalog to page 5
Torque-Angle Measurement Unit TAA series-6

Torque-Angle Measurement System TAA series TAA-HTG Series Twisting torque tests of doorknobs Product Configuration 1. Handheld Digital Torque Gauges : HTGA series Measuring rotating torque and twisting torque 2. Angle Meter Kit: AMK-360 Measure and output the angle 3. Software: Force Recorder Professional Drawing torque-angle graph at real time Required to measure with angle meter kit. Fixing the stay allows to start from 0 point and measure accurate angle measurement._ This unit includes items No.1~3 only. “4. Attachment” and “5. Stay” are also required for Torque-angle measurement. Page 8 for...

 Open the catalog to page 6
Torque-Angle Measurement Unit TAA series-7

Torque-Angle Measurement System TAA series [TAA-HTG series specification] *1 ( ): Required capacity to be selected. *2 kgf-m/kgf-cm, lbf-in/ozf-in are only available for international model. *3 The capacity of the entire TAA-HTG unit is limited by the capacity of the selected HTGA model. *4 USB flash drive is not included in TAA-HTG series. *5 Stay (Custom-made), optional attachment, and PC are not included in TAA-HTG series.. [Software operating environment] Operating environment [Downloadable Graphing Software Option] *1 When -NEXT option is applied, the dedicated download card providing the...

 Open the catalog to page 7
Torque-Angle Measurement Unit TAA series-8

IMADA CO., LTD. Torque-Angle Measurement System TAA series Related Attachments (TAA-HTG series) Small table and pins HT-ST Wide table HT-STW Light weight small table for HTG For gripping small samples such as small bottle and key. 3 pin options available (standard, notch, and long type). Wide type of HT-ST for gripping samples from φ10 to 100m. 3 pin options available (standard, notch, and long type). For small torque measurement with light weight small table. 3 pin options available (standard, notch, and long type). Light weight wide table for HTG HT-STLW Torque driver HT-DBH Wide type of HT-STL...

 Open the catalog to page 8
Torque-Angle Measurement Unit TAA series-9

IMADA CO., LTD. Torque-Angle Measurement System TAA series Custom-made example of stay 2 legs type - Suitable for use in limited space - For stable torque measurement - When space is enough for fixing the 4 legs Handle type - When there is no space for fixing the leg - Lower accuracy of meaurement due to handheld testing * The stay is required to measure with angle meter unit. Fixing the stay allows to start from 0 point and measure accurate angle measurement. * Please contact authorized local distributor or us for custom-made order.

 Open the catalog to page 9
Torque-Angle Measurement Unit TAA series-10

IMADA CO., LTD. Torque-Angle Measurement System TAA series [Calibration certificate & ISO/IEC 17025 calibration services] -We are the accredited ISO / IEC 17025: 2017 Calibration Organization with the in-house Calibration Service facility. -The Calibration Service and Issuing of the Calibration Certificates and Traceability Charts available at cost. -For further information, please kindly contact the local authorized distributor or us. [Cautions] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not...

 Open the catalog to page 10

All IMADA catalogs and technical brochures

  1. SH series

    5  Pages

  2. MS series

    4  Pages

  3. KV series

    3  Pages

  4. HV series

    5  Pages

  5. FCA-50N

    3  Pages

  6. GTW-2500N

    4  Pages

  7. WL01 series

    5  Pages

  8. P180-200N

    6  Pages

  9. SW series

    6  Pages

  10. VWF-10N

    7  Pages

  11. LMU/LU series

    6  Pages

  12. GP-15/30

    4  Pages

  13. KC series

    4  Pages

  14. DPUH series

    7  Pages

  15. DPU series

    7  Pages

  16. SHF series

    6  Pages

  17. SCX series

    5  Pages

  18. LM/LC series

    7  Pages

  19. CHX Series

    6  Pages

  20. TFX Series

    4  Pages

  21. SKM-1000N

    7  Pages

  22. DM-2000N

    7  Pages

  23. PK2-1500N

    4  Pages

  24. TS-5000N

    3  Pages

  25. APR-97

    3  Pages

  26. ZU series

    5  Pages

  27. FC series

    6  Pages

  28. MH2 series

    7  Pages

  29. FRTS series

    6  Pages

  30. CBJ-200N

    4  Pages

  31. SJS-100N-L/S

    5  Pages

  32. P90‐200N

    7  Pages

  33. MTS series

    7  Pages

  34. COF series

    6  Pages

  35. CCJ series

    7  Pages

  36. Force logger

    5  Pages

  37. PGC series

    4  Pages

  38. GC-60/100

    4  Pages

  39. FP-50/51

    3  Pages

  40. XST-500N

    4  Pages

  41. FBO-CFX

    3  Pages

  42. grp-50

    3  Pages

  43. SK series

    6  Pages

  44. FCA-DSV-50N

    4  Pages

  45. ZLINK4

    5  Pages

  46. SDT series

    4  Pages

  47. MED-NPT-200N

    4  Pages

  48. MED-ACU-2N

    3  Pages

  49. TKS-20N/250N

    6  Pages

  50. BT series

    6  Pages

  51. SQ series

    4  Pages

  52. CW-500N

    4  Pages

  53. MED-IS-20N

    3  Pages

  54. MED-SCT-500N

    3  Pages

  55. WG series

    5  Pages

  56. SP series

    4  Pages

  57. PG series

    4  Pages

  58. PC series

    4  Pages

  59. P45-50N

    4  Pages

  60. GC-5/15

    4  Pages

  61. CP-150N

    3  Pages

  62. PPC-5000N

    4  Pages

  63. DSV series

    6  Pages

  64. AMK series

    4  Pages

  65. ST-SS

    2  Pages

  66. SJ series

    6  Pages

  67. RSH series

    5  Pages

  68. HFC-50N

    4  Pages

  69. ZW1-10kN

    6  Pages

  70. CW-5000N

    4  Pages

  71. LH-500N

    5  Pages

  72. UK series

    5  Pages

  73. PT series

    6  Pages

  74. PSH series

    5  Pages

  75. PCA-150N

    3  Pages

  76. CH-5000N

    4  Pages

  77. FB/FS series

    5  Pages

  78. PS/PSS series

    5  Pages

  79. PSM series

    5  Pages

  80. SHT-5N

    3  Pages

  81. Force Gauges

    4  Pages

  82. DS2 series

    4  Pages

  83. F-S Master

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.