Sensor Interchangeable Amplifier eZT
8Pages

{{requestButtons}}

Catalog excerpts

Sensor Interchangeable Amplifier eZT - 1

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT -Available for various measurements by replacing different loadcells without accuracy adjustment. -Fast sampling for both Peak Values and Continuous Data, achieving high reproducibility -Clear OLED display with a variety of significant capabilities -Measurement benefit increased by external output and practical functions -Allows easy Data acquisition and management with the included software [Evolution to the Next Series] Next Series is a generic term for IMADA measurement devices with upgraded functions and performances with the essential modifications. New Series: eZT Firmware Ver.5 or later. New Features - Increased measurement stability achieved from further noise reduction to the measurement circuit. Analog output comparison Yellow: Next series/Green: Old Model - Force gauge program (firmware) online updates available. - Various software and additional functions downloadable to increase the measurement conveniences.

Open the catalog to page 1
Sensor Interchangeable Amplifier eZT - 2

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT [Features] Internal Memory The OLED provides excellent contrast and high visibility, which reduces errors in reading measurement results. In addition, the display screen can be divided into three sections, allowing to customize the display contents for liking, such as calendar, bar graph and Comparator setting values on the top and bottom. In addition, it has various display capabilities such as a multi-language setting menu and overload warning display. By providing a wide range of...

Open the catalog to page 2
Sensor Interchangeable Amplifier eZT - 3

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT (1) Equipped with Displacement Output Function eZT enables you to display displacement value on the top by connecting linear scale. Also, outputting the force-displacement data is available by using included or optional software. (2) USB flash-drive for Continuous Data Storage To USB flash-drive (*sold separately) Continuous data selected: -1 data/sec, 50 data/sec, 100 data/sec -Single data (with the button press) Data saved in CSV format. USB flash-drive is sold separately *Please...

Open the catalog to page 3
Sensor Interchangeable Amplifier eZT - 4

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT *1 The accuracy of load cell is added when using connected with a load cell. *2 Up to 100 data/sec. is saved in USB memory (selectable among 1, 50, and 100 /sec) *3 The battery is more consumed when connected to USB flash drive or a linear scale. *4 Some linear scales may not be available even if they meet the mentioned specifications. *5 Please refer to [Included Accessory] below for the details. *6 USB flash drive is not included. Overall accuracy is calculated as the total of the...

Open the catalog to page 4
Sensor Interchangeable Amplifier eZT - 5

IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT Main Functions -Easy Importing of the Measurement Data -Display Acquired Data Value Statistics: -Maximum / Minimum / Average Values. -Data saved in CSV format -Continuous Data acquisition up to 10 times per second. -Force-Gauge Function Settings. Operating environment - OS: 8.1/10/11 - Hardware: CPU 1GHz or more recommended Memory 2GB or more recommended Hard disk 10GB (Data storage area) or more - Platform: .NET Framework 4.8 or later

Open the catalog to page 5
Sensor Interchangeable Amplifier eZT - 6

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT *1 To use this product, user & product registration on IMADA Connected and downloading the software are required. Only Next Series products (For the eZT series, firmware versions 5.00 or are available for the product registration. An Internet connection is required in process of user & product registration and downloading the software.

Open the catalog to page 6
Sensor Interchangeable Amplifier eZT - 7

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT [Related Force Gauges] Digital force gauge ZTS/ZTA series Sensor-separate force gauge ZTS/ZTA Series Desktop Force Amplifier FA Plus2 series Functional yet user-friendly model force gauge. External sensor type for use in the restricted environment (narrow space etc.) or installing into the specific facilities. Ideal for integration into facilities due to the box-shaped design.

Open the catalog to page 7
Sensor Interchangeable Amplifier eZT - 8

IMADA CO.,LTD. eZ-Connect Series: Sensor Interchangeable Amplifier eZT Unit: mm *Please refer to load cell’s specification sheet for each dimension. [Cautions] - Information in this document is subject to change without prior notice. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Note that the allowable values may vary slightly depending on the unit selected on display. Please contact us for more information and details....

Open the catalog to page 8

All IMADA catalogs and technical brochures

  1. KC series

    4 Pages

  2. ZTS series

    7 Pages

  3. ZTA series

    8 Pages

  4. FSA series

    7 Pages

  5. MTS series

    7 Pages

  6. XST-500N

    3 Pages

  7. TS-5000N

    3 Pages

  8. SHF series

    5 Pages

  9. GTW-2500N

    4 Pages

  10. CCJ series

    6 Pages

  11. DPU series

    7 Pages

  12. SKM-1000N

    6 Pages

  13. PGC series

    4 Pages

  14. DM-2000N

    6 Pages

  15. CBJ-200N

    4 Pages

  16. FBO-CFX

    3 Pages

  17. COF series

    7 Pages

  18. PK2-1500N

    4 Pages

  19. SW series

    7 Pages

  20. grp-50

    3 Pages

  21. P180-200N

    6 Pages

  22. P90‐200N

    7 Pages

  23. ZU series

    6 Pages

  24. SK series

    6 Pages

  25. SCX series

    5 Pages

  26. CHX Series

    6 Pages

  27. TFX Series

    4 Pages

  28. FCA-DSV-50N

    4 Pages

  29. IPTS-20N/50N

    6 Pages

  30. SJS-100N-L/S

    5 Pages

  31. VWF-10N

    6 Pages

  32. APR-97

    3 Pages

  33. ZLINK4

    5 Pages

  34. SDT series

    4 Pages

  35. MED-NPT-200N

    4 Pages

  36. MED-ACU-2N

    3 Pages

  37. TKS-20N/250N

    6 Pages

  38. BT series

    6 Pages

  39. HV series

    5 Pages

  40. SQ series

    4 Pages

  41. CW-500N

    4 Pages

  42. Force logger

    5 Pages

  43. MED-IS-20N

    3 Pages

  44. FC series

    6 Pages

  45. EMX-1000N

    7 Pages

  46. MED-SCT-500N

    3 Pages

  47. WG series

    5 Pages

  48. GP-15/30

    4 Pages

  49. GC-60/100

    4 Pages

  50. FP-50/51

    3 Pages

  51. SP series

    4 Pages

  52. PG series

    4 Pages

  53. PC series

    4 Pages

  54. P45-50N

    4 Pages

  55. GC-5/15

    4 Pages

  56. CP-150N

    3 Pages

  57. FRTS series

    6 Pages

  58. MS series

    5 Pages

  59. PPC-5000N

    4 Pages

  60. DSV series

    6 Pages

  61. WL01 series

    5 Pages

  62. MH2 series

    6 Pages

  63. AMK series

    4 Pages

  64. ST-SS

    2 Pages

  65. SJ series

    6 Pages

  66. RSH series

    5 Pages

  67. HFC-50N

    4 Pages

  68. ZW1-10kN

    6 Pages

  69. CW-5000N

    4 Pages

  70. CH-5000N

    4 Pages

  71. LH-500N

    5 Pages

  72. UK series

    5 Pages

  73. PT series

    6 Pages

  74. FCA-50N

    3 Pages

  75. KV series

    3 Pages

  76. SH series

    5 Pages

  77. PSH series

    5 Pages

  78. PCA-150N

    3 Pages

  79. CH-5000N

    4 Pages

  80. FB/FS series

    5 Pages

  81. PSM series

    5 Pages

  82. SHT-5N

    3 Pages

  83. Force Gauges

    4 Pages

  84. DS2 series

    4 Pages

  85. LMU series

    8 Pages

  86. ZD series

    8 Pages

  87. F-S Master

    5 Pages

Archived catalogs

  1. ZTS series

    7 Pages

  2. ZTA series

    9 Pages

  3. FCA-DS2-50N

    3 Pages

  4. MX-1000N

    3 Pages

  5. MX-500N

    3 Pages

  6. HV-3000N

    3 Pages

  7. MS-50N

    4 Pages

  8. SV series

    4 Pages

  9. FA Plus

    4 Pages

  10. HV series

    3 Pages