Overview: The SCX series by IMADA CO., LTD. is an extra compact tension and compression load cell designed for precise force measurement in limited access areas. It features a miniature body with dimensions of 16(L)x12(W)x19.1(H) mm and is equipped with M6 threads for easy integration into various systems.
Key Features:
  • Miniature size suitable for integration into machines like tactile test systems and medical equipment.
  • Mechanical stopper to reduce overload risk.
  • Compatible with five selectable amplifiers for tailored applications.
  • Graphing software available for result analysis.
Specifications:
  • Accuracy: +/- 1.0% Full Scale (F.S.).
  • Rated Output: 1.5-2.2mV/V.
  • Safe Overload Rating: 150%.
  • Operating Temperature: -10 to 60 degrees Celsius.
  • Protection Rating: IP65 for the sensor part.
Amplifiers and Indicators: The SCX series can be paired with various amplifiers, including handheld and desktop types, offering features like data saving to USB and load cell interchangeability. The QSMA-400 amplifier allows connection of up to four different load cells simultaneously.
Models and Capacities: The SCX series includes models with capacities ranging from 100N to 2000N, with custom-made measuring shafts available for mounting attachments.
Related Products: Other load cells in the IMADA range include the DPU series for general use, the LMU series for extra small applications, and the LU series for small type load cells.
Graphing Software: The Force Recorder Series offers real-time graph plotting and analysis, available in Light, Standard, Professional, and Plus versions.
Cautions: The document advises against exceeding the load cell's capacity, applying force from incorrect directions, and using the product in extreme environmental conditions. It also notes that the information is subject to change without notice.
See more

Catalog excerpts

SCX series-1

IMADA CO., LTD. Extra Compact Tension and Compression Load Cell SCX series Extra Compact Tension and Compression Load Cell SCX series - Extra compact body to suit measurement where access is limited - Mountable to equipment with female threads on both ends of the sensor - Reduces risk of overload with mechanical stopper * - 5 selectable amplifiers to fit for purpose - Graphing software (separately sold) available for analysis of results * It does not guarantee complete prevention of overload. SCX series * IP (Ingress Protection) is a standard which is based on IEC Standard for solid foreign materials, electric devices for water and cabinet. * eZ-Connect series load cells are interchangeable and can be connected to one amplifier without adjustment, therefore suitable for measurement of different types of force (e.g. tension and torque) or ranges (e.g. small force and high capacity). Features Miniature Body Very small in size; 16(L)x12(W)x19.1(H) mm Fit for Integration M6 threads allow easy integration * Do not screw in more than 3mm deep into the M6 threads to avoid damaging the sensor. Testing Examples Integration into a variety of machine including tactile test system and medical equipment, measurement of gripping force of cabinet drawers, etc.

 Open the catalog to page 1
SCX series-2

IMADA CO., LTD.Extra Compact Tension and Compression Load Cell SCX seriesSpecifications Model It is the accuracy of the sensor only. Refer to page 3 for the accuracy of combinations with the amplifier (indicator) under [Models of Sensors Combined with Indicators (Separated sensor models)] and [Models of eZ-Connect Series (Sensor Interchangeable Model)]. IP is only approved for the sensor part. The amplifier (indicator), the connector parts, and cable are not secured. Refer to specification of [Options Available for Load cell Cable] to change cable length or so. An amplifier (indicator) is required...

 Open the catalog to page 2
SCX series-3

IMADA CO., LTD.Extra Compact Tension and Compression Load Cell SCX series [Models of Load Cell Only] Model *A custom-made measuring shaft is available for mounting attachments with M6 threads. [Connector Type] *1 Total accuracy when combined with the eZ-Connect series amplifier. e.g. Total accuracy of eCLFX and eZT +/-1.2%F.S. or less (Load cell: +/-1.0%F.S. or less + Amplifier: +/-0.2%F.S. or less) * Please refer to the accuracy of the sensor of eZ-Connect in the Specifications table.

 Open the catalog to page 3
SCX series-4

Extra Compact Tension and Compression Load Cell SCX series - Other Load Cells *1 The linear scale connection is limited to models equipped with the displacement output function (ZTA series, eZT, FA Plus2, eFA Plus2).

 Open the catalog to page 4
SCX series-5

IMADA CO., LTD. Extra Compact Tension and Compression Load Cell SCX series M6 effective 3 * Same for the other side * Do not screw in more than 3 mm as the sensor may be damaged. [Cautions] - Information in this document is subject to change without prior notice. - This document introduces product descriptions and handling precautions, and it does not guarantee the features or safety mentioned therein. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction...

 Open the catalog to page 5

All IMADA catalogs and technical brochures

  1. SH series

    5  Pages

  2. MS series

    4  Pages

  3. KV series

    3  Pages

  4. HV series

    5  Pages

  5. FCA-50N

    3  Pages

  6. GTW-2500N

    4  Pages

  7. WL01 series

    5  Pages

  8. P180-200N

    6  Pages

  9. SW series

    6  Pages

  10. VWF-10N

    7  Pages

  11. LMU/LU series

    6  Pages

  12. GP-15/30

    4  Pages

  13. KC series

    4  Pages

  14. DPUH series

    7  Pages

  15. DPU series

    7  Pages

  16. SHF series

    6  Pages

  17. LM/LC series

    7  Pages

  18. CHX Series

    6  Pages

  19. TFX Series

    4  Pages

  20. SKM-1000N

    7  Pages

  21. DM-2000N

    7  Pages

  22. PK2-1500N

    4  Pages

  23. TS-5000N

    3  Pages

  24. APR-97

    3  Pages

  25. ZU series

    5  Pages

  26. FC series

    6  Pages

  27. MH2 series

    7  Pages

  28. FRTS series

    6  Pages

  29. CBJ-200N

    4  Pages

  30. SJS-100N-L/S

    5  Pages

  31. P90‐200N

    7  Pages

  32. MTS series

    7  Pages

  33. COF series

    6  Pages

  34. CCJ series

    7  Pages

  35. Force logger

    5  Pages

  36. PGC series

    4  Pages

  37. GC-60/100

    4  Pages

  38. FP-50/51

    3  Pages

  39. XST-500N

    4  Pages

  40. FBO-CFX

    3  Pages

  41. grp-50

    3  Pages

  42. SK series

    6  Pages

  43. FCA-DSV-50N

    4  Pages

  44. ZLINK4

    5  Pages

  45. SDT series

    4  Pages

  46. MED-NPT-200N

    4  Pages

  47. MED-ACU-2N

    3  Pages

  48. TKS-20N/250N

    6  Pages

  49. BT series

    6  Pages

  50. SQ series

    4  Pages

  51. CW-500N

    4  Pages

  52. MED-IS-20N

    3  Pages

  53. MED-SCT-500N

    3  Pages

  54. WG series

    5  Pages

  55. SP series

    4  Pages

  56. PG series

    4  Pages

  57. PC series

    4  Pages

  58. P45-50N

    4  Pages

  59. GC-5/15

    4  Pages

  60. CP-150N

    3  Pages

  61. PPC-5000N

    4  Pages

  62. DSV series

    6  Pages

  63. AMK series

    4  Pages

  64. ST-SS

    2  Pages

  65. SJ series

    6  Pages

  66. RSH series

    5  Pages

  67. HFC-50N

    4  Pages

  68. ZW1-10kN

    6  Pages

  69. CW-5000N

    4  Pages

  70. LH-500N

    5  Pages

  71. UK series

    5  Pages

  72. PT series

    6  Pages

  73. PSH series

    5  Pages

  74. PCA-150N

    3  Pages

  75. CH-5000N

    4  Pages

  76. FB/FS series

    5  Pages

  77. PS/PSS series

    5  Pages

  78. PSM series

    5  Pages

  79. SHT-5N

    3  Pages

  80. Force Gauges

    4  Pages

  81. DS2 series

    4  Pages

  82. F-S Master

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.