Introduction
This document provides technical specifications and usage guidelines for the IMADA special use load cells PK1-500N and PK2-1500N, designed for measuring forces on two-wheeler handbrakes and vehicle foot pedals, respectively.
International Protection (IP) Rating
The load cells have an IP65 rating, indicating complete protection against dust and resistance to water projected in powerful jets. This rating applies only to the load cell itself, not the amplifier or connector parts.
Specifications
  • Model: PK1-500N for handbrakes, PK2-1500N for foot pedals.
  • Capacity: 500N for PK1-500N, 1500N for PK2-1500N.
  • Rated Output: 1.5mV/V.
  • Recommended Voltage: Less than 10V.
  • Cable Length: Approximately 1.5m.
  • Weight: Approximately 150g for PK1-500N, 270g for PK2-1500N.
Connector Types
Available in 5-pin, 6-pin, or without connector options, compatible with various IMADA products and equipment.
Amplifiers and Indicators
Compatible with ZTA, ZTS, and FA Plus2 series for handheld and desktop use. The eZ-Connect series allows for interchangeable load cells and simultaneous connection of up to four different load cells.
Related Cables
  • CB-108 and CB-118: Analog cables for connection to multimeters or oscilloscopes.
  • CB-208: RS232C cable for PC connection.
  • CB-908: Open end connection cable for unique equipment.
Cautions
  • Do not exceed the load cell's capacity or apply force incorrectly.
  • Avoid using in environments with extreme temperature changes, high humidity, or dust.
  • Information is subject to change without notice.
Contact Information
IMADA CO., LTD, Toyohashi, Japan. For more details, visit their website or contact via email.
See more

Catalog excerpts

PK2-1500N-1

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N Load cell for Two-wheeler Handbrakes PK1-500N Load cell for Vehicle Foot Pedals PK2-1500N Measure force acting on foot pedals or handbrakes. You can simply clip or mount on the load cell to perform measurements. Setting image *Grip the load cell and the brake together to measure force after mounting. Setting image *Clip a load cell onto a pedal and step them on together to measure force. What is IP? IP(International Protection) is a standard which is based on IEC Standard 529 for solid foreign materials, electric devices for water and cabinet. IP65 The second code (IP 0 to 8 for water penetration) The first code (IP 0 to 8 for human body and sold foreign materials) Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects at least for 3 minutes 100 liter per minute. No ingress of dust; complete protection against contact (dust tight) :eZ-Connect series eZ-Connect is composed of an amplifier and load cells. Enables to replace load cells without additional adjustment. Suitable for different types of tests such as tension and torque, measuring from low load to high load etc. Available load cells have a mark

 Open the catalog to page 1
PK2-1500N-2

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N * When ordering only the load cell, PK1-500N or PK2-1500N, select the connector shape and add the code to the end of the load cell model. e.g. For selecting 5pins: PK1-500N-5P

 Open the catalog to page 2
PK2-1500N-3

IMADA CO.,LTDSpecial Use Load Cell PK1-500N/PK2-1500N[Available Amplifiers (Indicators)]Separated Sensor ModelHandheld type ZTS series Handheld type ZTA series Handheld use Higher accuracy Handheld use Higher accuracy I/O displacement Data saving to USB - Higher accuracy Handheld type eZT Quad Sensor Measuring Amplifier QSMA-400 - Load cell interchangeable (such as measurement of tension and torque, or low and high load) - Load cell interchangeable (such as measurement of tension and torque, or low and high load) - Up to 4 different load cells can be connected Simultaneously. (Load cell interchangeable)...

 Open the catalog to page 3
PK2-1500N-4

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N [Related Cables] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the environments including fierce temperature changes, high temperature, high humidity, near water, dusty place....

 Open the catalog to page 4

All IMADA catalogs and technical brochures

  1. SH series

    5  Pages

  2. MS series

    4  Pages

  3. KV series

    3  Pages

  4. HV series

    5  Pages

  5. FCA-50N

    3  Pages

  6. GTW-2500N

    4  Pages

  7. WL01 series

    5  Pages

  8. P180-200N

    6  Pages

  9. SW series

    6  Pages

  10. VWF-10N

    7  Pages

  11. LMU/LU series

    6  Pages

  12. GP-15/30

    4  Pages

  13. KC series

    4  Pages

  14. DPUH series

    7  Pages

  15. DPU series

    7  Pages

  16. SHF series

    6  Pages

  17. SCX series

    5  Pages

  18. LM/LC series

    7  Pages

  19. CHX Series

    6  Pages

  20. TFX Series

    4  Pages

  21. SKM-1000N

    7  Pages

  22. DM-2000N

    7  Pages

  23. TS-5000N

    3  Pages

  24. APR-97

    3  Pages

  25. ZU series

    5  Pages

  26. FC series

    6  Pages

  27. MH2 series

    7  Pages

  28. FRTS series

    6  Pages

  29. CBJ-200N

    4  Pages

  30. SJS-100N-L/S

    5  Pages

  31. P90‐200N

    7  Pages

  32. MTS series

    7  Pages

  33. COF series

    6  Pages

  34. CCJ series

    7  Pages

  35. Force logger

    5  Pages

  36. PGC series

    4  Pages

  37. GC-60/100

    4  Pages

  38. FP-50/51

    3  Pages

  39. XST-500N

    4  Pages

  40. FBO-CFX

    3  Pages

  41. grp-50

    3  Pages

  42. SK series

    6  Pages

  43. FCA-DSV-50N

    4  Pages

  44. ZLINK4

    5  Pages

  45. SDT series

    4  Pages

  46. MED-NPT-200N

    4  Pages

  47. MED-ACU-2N

    3  Pages

  48. TKS-20N/250N

    6  Pages

  49. BT series

    6  Pages

  50. SQ series

    4  Pages

  51. CW-500N

    4  Pages

  52. MED-IS-20N

    3  Pages

  53. MED-SCT-500N

    3  Pages

  54. WG series

    5  Pages

  55. SP series

    4  Pages

  56. PG series

    4  Pages

  57. PC series

    4  Pages

  58. P45-50N

    4  Pages

  59. GC-5/15

    4  Pages

  60. CP-150N

    3  Pages

  61. PPC-5000N

    4  Pages

  62. DSV series

    6  Pages

  63. AMK series

    4  Pages

  64. ST-SS

    2  Pages

  65. SJ series

    6  Pages

  66. RSH series

    5  Pages

  67. HFC-50N

    4  Pages

  68. CW-5000N

    4  Pages

  69. LH-500N

    5  Pages

  70. UK series

    5  Pages

  71. PT series

    6  Pages

  72. PSH series

    5  Pages

  73. PCA-150N

    3  Pages

  74. CH-5000N

    4  Pages

  75. FB/FS series

    5  Pages

  76. PS/PSS series

    5  Pages

  77. PSM series

    5  Pages

  78. SHT-5N

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.