Catalog excerpts
Load cell for Two-wheeler Handbrakes PK1-500N Load cell for Vehicle Foot Pedals PK2-1500N -Measuring forces acting on foot pedals or handbrakes. -Easy attaching and measuring force on pedals or on handbrake levers. PK1-500N(for Two-wheelers) Measurement is possible by attaching the load cell on Measurement is possible by hooking the load cell on Using Image a hand brake and gripping them together. a pedal and stepping them on together. [Load cell specification] Model For two-wheeler hand brakes For vehicle foot pedals Cable length Size International Protection IP65* Partly in accordance with JIS D 1034 (1999) Method Of Brake Test For Motor Cycles Approved Standard * IP65 is only approved for the load cell itself. The amplifier (the indicator) and the connector parts are not approved.
Open the catalog to page 1[eZ-Connect series load cell specification] Model For vehicle foot pedals International Protection *1 IP is only approved for the load cell. An amplifier (an indicator)/ the connecting part/ the connector part are not approved. *2 Please note there is NO eZ-Connect series of PK1-500N. *3 Plaase refer Page 3 for eZ-Connect series detail. Force value display/ Data management/ Operating external device are ALL possible by combining with IMADA amplifier. →There are 3 selectable amplifiers. Amplifier ZT series FA-Plus eZ-Connect series :eZT Sensor separate type force gauge ZT series Feature High...
Open the catalog to page 2Desktop amplifier FA Plus The box shape realizes easy installations on a desk or in equipment Accuracy Guarantee ZT シリーズと同等の 2000 個/秒のサンプリング the -The inspection certificate is attached only when below set models are ordered. -The inspection certificate is NOT attached when FA Plus and the load cell are separately ordered. -Please request us the calibration certificate if necessary. [The range list connecting with FA Plus] Model The sampling rate is equals to ZT series 2000Hz. * Please refer to the each amplifier specification for the detail. *1The accuracy is only available for combinations...
Open the catalog to page 3Non-slip processing Non-slip processing This product is designed for force measurement only. Do not use it for other purpose. Please pay close attention to install this products. Never apply strong force or impact especially on the sensing direction. Do not apply bending or torsion stress when setting up the sensing shaft to a measuring object. Do not use in the condition of rapid temperature changes, high temperature, high humidity, near water and dusty place. The contents may be changed without notice in advance. Please note the allowable values are a little different by the selecting...
Open the catalog to page 4All IMADA catalogs and technical brochures
-
Force Recorder Next Series
8 Pages
-
Force Recorder Professional
7 Pages
-
Force Recorder Standard
7 Pages
-
OP-MX2EMX-IC/OP-MX250-IC
4 Pages
-
KC series
4 Pages
-
LM/LC/DD2/LMT series
7 Pages
-
CLFX / CFX Series
5 Pages
-
ZTS series
7 Pages
-
ZTA series
8 Pages
-
FSA series
7 Pages
-
FA Plus2 / eFA Plus2
11 Pages
-
HTGS/HTGA series
8 Pages
-
Specification list of cables
7 Pages
-
LMU/LU/ZD series
7 Pages
-
A-40/60,S-40/60
4 Pages
-
MTS series
7 Pages
-
XY-500N series
5 Pages
-
XST-500N
3 Pages
-
TS-5000N
3 Pages
-
SHF series
5 Pages
-
GTW-2500N
4 Pages
-
CCJ series
6 Pages
-
Vise Grips GT-30/2000N
4 Pages
-
DPU series
7 Pages
-
SKM-1000N
6 Pages
-
PGC series
4 Pages
-
DM-2000N
6 Pages
-
CBJ-200N
4 Pages
-
FBO-CFX
3 Pages
-
COF series
7 Pages
-
PK2-1500N
4 Pages
-
SW series
7 Pages
-
grp-50
3 Pages
-
P180-200N
6 Pages
-
P90‐200N
7 Pages
-
ZU series
6 Pages
-
SK series
6 Pages
-
SCX series
5 Pages
-
CHX Series
6 Pages
-
Pen Type Load Cell PN-50N
4 Pages
-
Torque Load Cell eHT series
5 Pages
-
HTGS/HTGA-TFX Series
8 Pages
-
TFX Series
4 Pages
-
Driver Torque Meter I-8/I-80
4 Pages
-
FCA-DSV-50N
4 Pages
-
IPTS-20N/50N
6 Pages
-
Peeling Tester IPTS-5N
7 Pages
-
SJS-100N-L/S
5 Pages
-
VWF-10N
6 Pages
-
APR-97
3 Pages
-
Force Logger Plus
4 Pages
-
Force Recorder Plus
8 Pages
-
ZLINK4
5 Pages
-
SDT series
4 Pages
-
MED-LFA-20N/MED-VH-5N
4 Pages
-
MED-NPT-200N
4 Pages
-
MED-ACU-2N
3 Pages
-
TKS-20N/250N
6 Pages
-
BT series
6 Pages
-
GC-1100/1200/5000, GCF-1200
5 Pages
-
HV series
5 Pages
-
SQ series
4 Pages
-
CW-500N
4 Pages
-
Force logger
5 Pages
-
MED-IS-20N
3 Pages
-
FC series
6 Pages
-
EMX-1000N
7 Pages
-
MED-SCT-500N
3 Pages
-
WG series
5 Pages
-
GP-15/30
4 Pages
-
GC-60/100
4 Pages
-
FP-50/51
3 Pages
-
SP series
4 Pages
-
PG series
4 Pages
-
PC series
4 Pages
-
P45-50N
4 Pages
-
GC-5/15
4 Pages
-
CP-150N
3 Pages
-
Force gauge comparison table
4 Pages
-
Optional handle FOH
3 Pages
-
FRTS series
6 Pages
-
MS series
5 Pages
-
PPC-5000N
4 Pages
-
DSV series
6 Pages
-
WL01 series
5 Pages
-
Compression attachment table
3 Pages
-
MH2 series
6 Pages
-
PTW-10IN/OT-8IN
3 Pages
-
AMK series
4 Pages
-
Universal Joint UJ series
4 Pages
-
ST-SS
2 Pages
-
SJ series
6 Pages
-
RSH series
5 Pages
-
HFC-50N
4 Pages
-
ZW1-10kN
6 Pages
-
CW-5000N
4 Pages
-
CH-5000N
4 Pages
-
LH-500N
5 Pages
-
UK series
5 Pages
-
PT series
6 Pages
-
FCA-50N
3 Pages
-
PK1-500N series
4 Pages
-
KV series
3 Pages
-
SH series
5 Pages
-
PSH series
5 Pages
-
PCA-150N
3 Pages
-
CH-5000N
4 Pages
-
FB/FS series
5 Pages
-
PS/PSS series
5 Pages
-
PSM series
5 Pages
-
SHT-5N
3 Pages
-
180 degree Peeling Tester
5 Pages
-
Force gauge attachment
5 Pages
-
Force Gauges
4 Pages
-
DS2 series
4 Pages
-
LMU series
8 Pages
-
ZD series
8 Pages
-
F-S Master
5 Pages
-
Friction Testing System
1 Pages
-
Peel testing system
1 Pages
Archived catalogs
-
ZTS series
7 Pages
-
ZTA series
9 Pages
-
Wire Harness Pull Tester
3 Pages
-
FCA-DS2-50N
3 Pages
-
MX-1000N
3 Pages
-
MX-500N
3 Pages
-
HV-3000N
3 Pages
-
MS-50N
4 Pages
-
SV series
4 Pages
-
Tensile Load Cell ZW1-10kN
6 Pages
-
PK1-500N/PK2-1500N
4 Pages
-
FA Plus
4 Pages
-
HV series
3 Pages