Catalog excerpts
IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series Downloadable Force - Time (Displacement) / Torque - Time (Angle) Graphing Software Force Recorder Next Series -Graph the relationship between force-time (displacement) & torque-time (angle) -Precise graphing and data analysis reflecting up to 2000 data/second possible with high-speed USB communication -Improve efficiency with measurement and analysis with assorted functions using graph overlay, test condition presets, annotation additions, and an easy-to-access smooth UI. -Additional functions are available for download from the user support site to cater to your needs -The basic Standard version and the Professional version with the Displacement / Angle data analysis function The software screen image *The Force Recorder Next Professional version *To use this product, user & product registration on IMADA Connected is required and please note that only Next Series products are available for the product registration. When downloading the software, please purchase the dedicated download card providing the redemption code. An Internet connection is required in this process. IMADA Connected: https://www.imada-connected.com/ *To check if your product is Next Series or not, please click this link.: https://www.forcegauge.net/en/service/next_series
Open the catalog to page 1IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series [Basic Functions] Force - Time(Displacement)/ Torque-Time (Angle) Graphing 【Graphing Speed】 -Graph force-time (displacement) / torque-time (angle) values - max. 2000 data/second *1 -Adjustable Data Acquisition rate: Between 0.1 to 2000Hz Graphing Recording Window 【Manual/Automatic Recording】 -Manual recording Use the REC and STOP buttons -Automatic recording With a trigger function that starts and stops recording when specific conditions such as the force value and time are met Record Start Button / Status...
Open the catalog to page 2IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series Data Output and Printing [Output and Printing] -Measurement results are saved as z3b files and CSV files. -The Print Command allows the output of measurement data in a report format. Also, possible to save as PDF/Word, Excel, and images. -Possible to save graphs in images and statistical values in text to the clipboard [Special Order / Custom-Made Available] We are able to offer consultations and assistance for custom-made software to cater to your needs.
Open the catalog to page 3IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series When performing repetitive, automatic measurements using the Trigger function, an interval of approximately 3 seconds is required between the end of one recording and the start of the next recording to prevent loss of acquired data. The interval depends on the specification and settings of the PC.
Open the catalog to page 4IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series [Screen Descriptions] Main Tool Bar Open and close files, configure device settings, set user preferences etc. area, and check the software version, among other functions (Pre-recording settings) Recording Settings Window Settings before the measurement allow conditions to be automatically reflected for subsequent measurements. The settings remain while the software is running. The Record / Triggers / Graph and other items have preset functions available, helpful in re-testing under the same condition later with...
Open the catalog to page 5IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series Graph Area The area where the recorded graphs and also the re-opened graphs from the files are displayed. Use the Tool Bar icons to Display Reset / Section Data Settings, and the manual insertions of the annotations, etc. (Graph Viewing Window) Monitoring Window Statistics Window Feature examples: Adding Graphs / Insertion of Guidelines and Annotations to the Displayed Data / Graph Inversion / Data Save & Printing The Monitoring Window and the Statistics Windows open with a single click The following information...
Open the catalog to page 6IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series
Open the catalog to page 7IMADA CO.,LTD. Downloadable Force graphing software Force Recorder Next Series [IMPORTANT NOTICE] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various characteristics or safety. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - A force gauge (sold separately) is required to use this product. - This product is protected by Universal Copyright Convention and Japanese Copyright Act. - Returns are not...
Open the catalog to page 8All IMADA catalogs and technical brochures
-
Force Recorder Professional
7 Pages
-
Force Recorder Standard
7 Pages
-
OP-MX2EMX-IC/OP-MX250-IC
4 Pages
-
KC series
4 Pages
-
LM/LC/DD2/LMT series
7 Pages
-
CLFX / CFX Series
5 Pages
-
ZTS series
7 Pages
-
ZTA series
8 Pages
-
FSA series
7 Pages
-
FA Plus2 / eFA Plus2
11 Pages
-
HTGS/HTGA series
8 Pages
-
Specification list of cables
7 Pages
-
LMU/LU/ZD series
7 Pages
-
A-40/60,S-40/60
4 Pages
-
MTS series
7 Pages
-
XY-500N series
5 Pages
-
XST-500N
3 Pages
-
TS-5000N
3 Pages
-
SHF series
5 Pages
-
GTW-2500N
4 Pages
-
CCJ series
6 Pages
-
Vise Grips GT-30/2000N
4 Pages
-
DPU series
7 Pages
-
SKM-1000N
6 Pages
-
PGC series
4 Pages
-
DM-2000N
6 Pages
-
CBJ-200N
4 Pages
-
FBO-CFX
3 Pages
-
COF series
7 Pages
-
PK2-1500N
4 Pages
-
SW series
7 Pages
-
grp-50
3 Pages
-
P180-200N
6 Pages
-
P90‐200N
7 Pages
-
ZU series
6 Pages
-
SK series
6 Pages
-
SCX series
5 Pages
-
CHX Series
6 Pages
-
Pen Type Load Cell PN-50N
4 Pages
-
Torque Load Cell eHT series
5 Pages
-
HTGS/HTGA-TFX Series
8 Pages
-
TFX Series
4 Pages
-
Driver Torque Meter I-8/I-80
4 Pages
-
FCA-DSV-50N
4 Pages
-
IPTS-20N/50N
6 Pages
-
Peeling Tester IPTS-5N
7 Pages
-
SJS-100N-L/S
5 Pages
-
VWF-10N
6 Pages
-
APR-97
3 Pages
-
Force Logger Plus
4 Pages
-
Force Recorder Plus
8 Pages
-
ZLINK4
5 Pages
-
SDT series
4 Pages
-
MED-LFA-20N/MED-VH-5N
4 Pages
-
MED-NPT-200N
4 Pages
-
MED-ACU-2N
3 Pages
-
TKS-20N/250N
6 Pages
-
BT series
6 Pages
-
GC-1100/1200/5000, GCF-1200
5 Pages
-
HV series
5 Pages
-
SQ series
4 Pages
-
CW-500N
4 Pages
-
Force logger
5 Pages
-
MED-IS-20N
3 Pages
-
FC series
6 Pages
-
EMX-1000N
7 Pages
-
MED-SCT-500N
3 Pages
-
WG series
5 Pages
-
GP-15/30
4 Pages
-
GC-60/100
4 Pages
-
FP-50/51
3 Pages
-
SP series
4 Pages
-
PG series
4 Pages
-
PC series
4 Pages
-
P45-50N
4 Pages
-
GC-5/15
4 Pages
-
CP-150N
3 Pages
-
Force gauge comparison table
4 Pages
-
Optional handle FOH
3 Pages
-
FRTS series
6 Pages
-
MS series
5 Pages
-
PPC-5000N
4 Pages
-
DSV series
6 Pages
-
WL01 series
5 Pages
-
Compression attachment table
3 Pages
-
MH2 series
6 Pages
-
PTW-10IN/OT-8IN
3 Pages
-
AMK series
4 Pages
-
Universal Joint UJ series
4 Pages
-
ST-SS
2 Pages
-
SJ series
6 Pages
-
RSH series
5 Pages
-
HFC-50N
4 Pages
-
ZW1-10kN
6 Pages
-
CW-5000N
4 Pages
-
CH-5000N
4 Pages
-
LH-500N
5 Pages
-
UK series
5 Pages
-
PT series
6 Pages
-
FCA-50N
3 Pages
-
PK1-500N series
4 Pages
-
KV series
3 Pages
-
SH series
5 Pages
-
PSH series
5 Pages
-
PCA-150N
3 Pages
-
CH-5000N
4 Pages
-
FB/FS series
5 Pages
-
PS/PSS series
5 Pages
-
PSM series
5 Pages
-
SHT-5N
3 Pages
-
180 degree Peeling Tester
5 Pages
-
Force gauge attachment
5 Pages
-
Force Gauges
4 Pages
-
DS2 series
4 Pages
-
LMU series
8 Pages
-
ZD series
8 Pages
-
F-S Master
5 Pages
-
Friction Testing System
1 Pages
-
Peel testing system
1 Pages
Archived catalogs
-
ZTS series
7 Pages
-
ZTA series
9 Pages
-
Wire Harness Pull Tester
3 Pages
-
FCA-DS2-50N
3 Pages
-
MX-1000N
3 Pages
-
MX-500N
3 Pages
-
HV-3000N
3 Pages
-
MS-50N
4 Pages
-
SV series
4 Pages
-
Tensile Load Cell ZW1-10kN
6 Pages
-
PK1-500N/PK2-1500N
4 Pages
-
FA Plus
4 Pages
-
HV series
3 Pages