Catalog excerpts
IMADA CO., LTD ZT series Application Examples Force Gauge ZT series Application Examples Digital force gauge ZTS/ZTA series is equipped with various functions to realize more efficient and more advanced measurements. ZTS/ZTA series mutual functions Function1.Comparator Output ZT series is able to set an upper limit value and a lower limit value. The information in the setting range or not is output depending on the set values. Output Image Control Motorized test stands External devices Signal is sent when detecting -NG Force gauge LED luminescence In a case of the upper limit: 20.0N and the lower limit: 10.0N ◎Application Example 1: Advanced automatic operations for Compression test /Durability test and so on.◎ The force control mode is activated when the force gauge connect the test stand like MX2 series with a cable. Especially, it is effective for durability test due to the program setting such as pushing (pulling) at specific force and backing movement. It improves measuring work efficiency as well. Setting measuring speed and measuring times and applying specific force are available (Ex: Retort pouch durability test) ) Set the applied force on the force gauge Set the measuring speed and number of times of measurements ◎Application Example 2: Warning alarms for the applied force beyond the setting force◎ Connecting ZT series with a buzzer or a warning lamp is possible to detect a force abnormality when the applied force is over the upper limit. It is useful function The automatic measurement is started at the setting force, speed and numbers of times of measurements after pushing the button. When applied force is over 100N, Light or Buzz for early abnormality detection.
Open the catalog to page 1IMADA CO., LTD ZT series Application Examples Function 2. External Contact Point Function ZT series is equipped with the external contact point input function. This function activates the Zero Reset function for force values or the Send function which saves data when the external devices input the contact point. In other words, ZT series can be controled from external devices not only from the equipped buttons. External Equipment Zero Reset It is possible to control a force gauge from external equipment. Data Saving Command Operation Force gauge direct operation ◎Application Example 2:...
Open the catalog to page 2IMADA CO., LTD ZT series Application Examples ZTA series limited function Function 4. Capture 2 peak values at one measurement ZTA series is equipped with 2 peak values saving function. The function efficiently activates for the value rapid change even though the movement is small as a switch clicking. It makes speedy measurements and improves the measuring work efficiency. A General Switch Clicking Test ZTA series The peak of whole measurement The clicking value =The capturing necessary force A switch Repulsion force (force value) decreases after the switch clicking ↑The example photo of...
Open the catalog to page 3IMADA CO., LTD ZT series Application Examples Function 6. Capture Force/Displacement Peak Values ZTA series can save the peak force value and the displacement at the same time. The displacement at the captured peak force value. The peak force value Peak force value and displacement value are on a display of a force gauge. Using function 5 & 6 together realizes easier checking of force-displacement relationships Measurement Results Measurement Steps The peak force value and the displacement at the same time. Both manual operation and automatic operation are available Force-displacement...
Open the catalog to page 4All IMADA catalogs and technical brochures
-
Force Recorder Next Series
8 Pages
-
Force Recorder Professional
7 Pages
-
Force Recorder Standard
7 Pages
-
OP-MX2EMX-IC/OP-MX250-IC
4 Pages
-
KC series
4 Pages
-
LM/LC/DD2/LMT series
7 Pages
-
CLFX / CFX Series
5 Pages
-
ZTS series
7 Pages
-
ZTA series
8 Pages
-
FSA series
7 Pages
-
FA Plus2 / eFA Plus2
11 Pages
-
HTGS/HTGA series
8 Pages
-
Specification list of cables
7 Pages
-
LMU/LU/ZD series
7 Pages
-
A-40/60,S-40/60
4 Pages
-
MTS series
7 Pages
-
XY-500N series
5 Pages
-
XST-500N
3 Pages
-
TS-5000N
3 Pages
-
SHF series
5 Pages
-
GTW-2500N
4 Pages
-
CCJ series
6 Pages
-
Vise Grips GT-30/2000N
4 Pages
-
DPU series
7 Pages
-
SKM-1000N
6 Pages
-
PGC series
4 Pages
-
DM-2000N
6 Pages
-
CBJ-200N
4 Pages
-
FBO-CFX
3 Pages
-
COF series
7 Pages
-
PK2-1500N
4 Pages
-
SW series
7 Pages
-
grp-50
3 Pages
-
P180-200N
6 Pages
-
P90‐200N
7 Pages
-
ZU series
6 Pages
-
SK series
6 Pages
-
SCX series
5 Pages
-
CHX Series
6 Pages
-
Pen Type Load Cell PN-50N
4 Pages
-
Torque Load Cell eHT series
5 Pages
-
HTGS/HTGA-TFX Series
8 Pages
-
TFX Series
4 Pages
-
Driver Torque Meter I-8/I-80
4 Pages
-
FCA-DSV-50N
4 Pages
-
IPTS-20N/50N
6 Pages
-
Peeling Tester IPTS-5N
7 Pages
-
SJS-100N-L/S
5 Pages
-
VWF-10N
6 Pages
-
APR-97
3 Pages
-
Force Logger Plus
4 Pages
-
Force Recorder Plus
8 Pages
-
ZLINK4
5 Pages
-
SDT series
4 Pages
-
MED-LFA-20N/MED-VH-5N
4 Pages
-
MED-NPT-200N
4 Pages
-
MED-ACU-2N
3 Pages
-
TKS-20N/250N
6 Pages
-
BT series
6 Pages
-
GC-1100/1200/5000, GCF-1200
5 Pages
-
HV series
5 Pages
-
SQ series
4 Pages
-
CW-500N
4 Pages
-
Force logger
5 Pages
-
MED-IS-20N
3 Pages
-
FC series
6 Pages
-
EMX-1000N
7 Pages
-
MED-SCT-500N
3 Pages
-
WG series
5 Pages
-
GP-15/30
4 Pages
-
GC-60/100
4 Pages
-
FP-50/51
3 Pages
-
SP series
4 Pages
-
PG series
4 Pages
-
PC series
4 Pages
-
P45-50N
4 Pages
-
GC-5/15
4 Pages
-
CP-150N
3 Pages
-
Force gauge comparison table
4 Pages
-
Optional handle FOH
3 Pages
-
FRTS series
6 Pages
-
MS series
5 Pages
-
PPC-5000N
4 Pages
-
DSV series
6 Pages
-
WL01 series
5 Pages
-
Compression attachment table
3 Pages
-
MH2 series
6 Pages
-
PTW-10IN/OT-8IN
3 Pages
-
AMK series
4 Pages
-
Universal Joint UJ series
4 Pages
-
ST-SS
2 Pages
-
SJ series
6 Pages
-
RSH series
5 Pages
-
HFC-50N
4 Pages
-
ZW1-10kN
6 Pages
-
CW-5000N
4 Pages
-
CH-5000N
4 Pages
-
LH-500N
5 Pages
-
UK series
5 Pages
-
PT series
6 Pages
-
FCA-50N
3 Pages
-
PK1-500N series
4 Pages
-
KV series
3 Pages
-
SH series
5 Pages
-
PSH series
5 Pages
-
PCA-150N
3 Pages
-
CH-5000N
4 Pages
-
FB/FS series
5 Pages
-
PS/PSS series
5 Pages
-
PSM series
5 Pages
-
SHT-5N
3 Pages
-
180 degree Peeling Tester
5 Pages
-
Force gauge attachment
5 Pages
-
Force Gauges
4 Pages
-
DS2 series
4 Pages
-
LMU series
8 Pages
-
ZD series
8 Pages
-
F-S Master
5 Pages
-
Friction Testing System
1 Pages
-
Peel testing system
1 Pages
Archived catalogs
-
ZTS series
7 Pages
-
ZTA series
9 Pages
-
Wire Harness Pull Tester
3 Pages
-
FCA-DS2-50N
3 Pages
-
MX-1000N
3 Pages
-
MX-500N
3 Pages
-
HV-3000N
3 Pages
-
MS-50N
4 Pages
-
SV series
4 Pages
-
Tensile Load Cell ZW1-10kN
6 Pages
-
PK1-500N/PK2-1500N
4 Pages
-
FA Plus
4 Pages
-
HV series
3 Pages