FA Plus2 / eFA Plus2
11Pages

{{requestButtons}}

Catalog excerpts

FA Plus2 / eFA Plus2 - 1

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series Desktop Amplifier FA Plus2 Series -Ideal for integration into facilities due to the box-shaped design -Easy to combine with external devices such as PLC using the equipped output functions Fast sampling for both Peak Values and Continuous Data, achieving high reproducibility -High RS232C data output speed (continuous data rate: 100 data/sec) -Option of industrial power supply DC+24V is available [Evolution to the Next Series] Next Series is a generic term for IMADA measurement devices with upgraded functions and performances with the essential modifications. The devices enable to install additional functions from the user support site, IMADAConnected. On the website, related data such as software and instruction manuals can also be downloaded. New Series: FA Plus2 Series Firmware Ver.5 or later. New Features - Increased measurement stability achieved from further noise reduction to the measurement circuit. Analog output comparison Yellow: Next series/Green: Old Model - Measurement device program (firmware) online updates available. - Various software and additional functions downloadable to increase the measurement conveniences. IMADA Connected (https://www.imada-connected.com/)

Open the catalog to page 1
FA Plus2 / eFA Plus2 - 2

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series Features Control Functions Management Functions - Adjustable baud rate to fit to your facilities such as PLC - Easy output of continuous data to your facilities such as PLC due to high RS232C data output speed (continuous data rate: 100 data/sec) - Accurate and quick force judgement due to high comparator data rate (2000 data/sec) - Enables detection of load cell using A/D (Analog to Digital) value display - Reduces risks in operation by keeping a spare load cell using eZ Connect series [Main Functions] [Clear display] [Pass-fail judgement]...

Open the catalog to page 2
FA Plus2 / eFA Plus2 - 3

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO., LTD. Desktop Amplifier FA Plus2 Series *1 Accuracy +/- 0.2% F.S. is added. *2 The available units are different from Japanese domestic model and international one. *3 When you save data in USB memory stick, the sampling rate is selectable among 1, 50 and 100/sec. *4 Option of industrial power DC+24V is available. (Option: -DC) *5 Refer to the below software details. *6 USB flash drive is not included. *7 We offer calibration certification for eFA Plus2 connected with the load cell at extra charge. Please contact us for details. Main Functions...

Open the catalog to page 3
FA Plus2 / eFA Plus2 - 4

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series Main Options * Model with option follows the rules: FAP2-[load cell model]-[option model]. Example 1: FAP2-DPU-5.0.N -DC -AN Example 2: eFA Plus2-DC Example 3: Accuracy of 0.2% is required FAP2-DP.U-50N -HP0.2 *1 AC adapter is not included. *2 The response speed is higher than D/A (standard), but zero reset is invalid, and noises may be detected as the data is not filtered. *3 Cables are required when connected to multiple devices. *4 Some load cells are not available for it. Please contact us for details. *1 There is only one connector for...

Open the catalog to page 4
FA Plus2 / eFA Plus2 - 5

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series

Open the catalog to page 5
FA Plus2 / eFA Plus2 - 6

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series Model *1 FAP2 is abbreviation of FA Plus2. When purchase it, please write as FAP2.

Open the catalog to page 6
FA Plus2 / eFA Plus2 - 7

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series [Related Products] Mounting Stay A Type MSFF-A Mounting Stay B Type MSFF-B Signal Tower Light PLU-03 It shows the pass-fail results clearly. It can They are useful for integration into facilities. They are useful for integration into also alarm if the sensor is overloaded. (*1) Mounting to the panel type. facilities. Mounting to the bottom type. 37-pin connector Length of cable: 3m Separated Sensor Model Digital Force Gauge ZT series It can zero reset by stepping the switch. (*1, Indicator for hand use can be used in *2) various testing...

Open the catalog to page 7
FA Plus2 / eFA Plus2 - 8

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series *1 Open collector output. (Please keep source voltage less than 30V and current of 10mA.) *2 Please keep resistance 1kQ and more. *3 Differential voltage output between 2 wires. *4 The judgement done based on the displayed value. *5 Real-time value is referred for judgement at all times. *6 Pin #24-29 and #30 are short-circuited: ON. *7 Connect pin #32 (A+) and #34(B+) / #35(B-) in case of line driver output. Connect pin #33(oC1) / #35(OC2) in case of open collector output. (Keep voltage drop 0.5V and less.) *8 Enable to supply 5V 200mA at...

Open the catalog to page 8
FA Plus2 / eFA Plus2 - 9

FORCE MEASUREMENT FORCE MEASUREMENT IMADA CO., LTD. Desktop Amplifier FA Plus2 Series

Open the catalog to page 9
FA Plus2 / eFA Plus2 - 10

FORCE MEASUREMENT IMADA CO., LTD. Desktop Amplifier FA Plus2 Series FORCE MEASUREMENT When MSFF-A is mountedWhen MSFF-B is mounted Unit: mm

Open the catalog to page 10
FA Plus2 / eFA Plus2 - 11

IMADA CO., LTD. Desktop Amplifier FA Plus2 Series [Calibration Certification and ISO/IEC17025 calibration service] -We can offer calibration certification for FA Plus2 connected with the load cell. -We offer calibration certification for eFA Plus2 connected with the load cell at extra charge. -We also offer ISO/IEC17025 calibration service at extra charge. * Please contact us or your local distributor for detailed information. [Cautions] - Specifications are subject to change without prior notice. - A force gauge (sold separately) is required to use this product. - This product is designed...

Open the catalog to page 11

All IMADA catalogs and technical brochures

  1. KC series

    4 Pages

  2. ZTS series

    7 Pages

  3. ZTA series

    8 Pages

  4. FSA series

    7 Pages

  5. MTS series

    7 Pages

  6. XST-500N

    3 Pages

  7. TS-5000N

    3 Pages

  8. SHF series

    5 Pages

  9. GTW-2500N

    4 Pages

  10. CCJ series

    6 Pages

  11. DPU series

    7 Pages

  12. SKM-1000N

    6 Pages

  13. PGC series

    4 Pages

  14. DM-2000N

    6 Pages

  15. CBJ-200N

    4 Pages

  16. FBO-CFX

    3 Pages

  17. COF series

    7 Pages

  18. PK2-1500N

    4 Pages

  19. SW series

    7 Pages

  20. grp-50

    3 Pages

  21. P180-200N

    6 Pages

  22. P90‐200N

    7 Pages

  23. ZU series

    6 Pages

  24. SK series

    6 Pages

  25. SCX series

    5 Pages

  26. CHX Series

    6 Pages

  27. TFX Series

    4 Pages

  28. FCA-DSV-50N

    4 Pages

  29. IPTS-20N/50N

    6 Pages

  30. SJS-100N-L/S

    5 Pages

  31. VWF-10N

    6 Pages

  32. APR-97

    3 Pages

  33. ZLINK4

    5 Pages

  34. SDT series

    4 Pages

  35. MED-NPT-200N

    4 Pages

  36. MED-ACU-2N

    3 Pages

  37. TKS-20N/250N

    6 Pages

  38. BT series

    6 Pages

  39. HV series

    5 Pages

  40. SQ series

    4 Pages

  41. CW-500N

    4 Pages

  42. Force logger

    5 Pages

  43. MED-IS-20N

    3 Pages

  44. FC series

    6 Pages

  45. EMX-1000N

    7 Pages

  46. MED-SCT-500N

    3 Pages

  47. WG series

    5 Pages

  48. GP-15/30

    4 Pages

  49. GC-60/100

    4 Pages

  50. FP-50/51

    3 Pages

  51. SP series

    4 Pages

  52. PG series

    4 Pages

  53. PC series

    4 Pages

  54. P45-50N

    4 Pages

  55. GC-5/15

    4 Pages

  56. CP-150N

    3 Pages

  57. FRTS series

    6 Pages

  58. MS series

    5 Pages

  59. PPC-5000N

    4 Pages

  60. DSV series

    6 Pages

  61. WL01 series

    5 Pages

  62. MH2 series

    6 Pages

  63. AMK series

    4 Pages

  64. ST-SS

    2 Pages

  65. SJ series

    6 Pages

  66. RSH series

    5 Pages

  67. HFC-50N

    4 Pages

  68. ZW1-10kN

    6 Pages

  69. CW-5000N

    4 Pages

  70. CH-5000N

    4 Pages

  71. LH-500N

    5 Pages

  72. UK series

    5 Pages

  73. PT series

    6 Pages

  74. FCA-50N

    3 Pages

  75. KV series

    3 Pages

  76. SH series

    5 Pages

  77. PSH series

    5 Pages

  78. PCA-150N

    3 Pages

  79. CH-5000N

    4 Pages

  80. FB/FS series

    5 Pages

  81. PSM series

    5 Pages

  82. SHT-5N

    3 Pages

  83. Force Gauges

    4 Pages

  84. DS2 series

    4 Pages

  85. LMU series

    8 Pages

  86. ZD series

    8 Pages

  87. F-S Master

    5 Pages

Archived catalogs

  1. ZTS series

    7 Pages

  2. ZTA series

    9 Pages

  3. FCA-DS2-50N

    3 Pages

  4. MX-1000N

    3 Pages

  5. MX-500N

    3 Pages

  6. HV-3000N

    3 Pages

  7. MS-50N

    4 Pages

  8. SV series

    4 Pages

  9. FA Plus

    4 Pages

  10. HV series

    3 Pages