FORCE MEASUREMENT FORCE MEASUREMENT Flat Type Compression Load Cell CLFX/CFX series - Sensor surface with large area, suitable for soft and/or spherical samples - Thin (CLFX) and small (CFX) type available for measurements in limited space - 5 selectable amplifiers to fit for purpose - Graphing software (separately sold) available for analysis of results * IP (Ingress Protection) is a standard which is based on IEC Standard for solid foreign materials, electric devices for water and cabinet. * eZ-Connect series load cells 1Qf are interchangeable and can be connected to one amplifier without adjustment, therefore suitable for measurement of different types of force (e.g. tension and torque) or ranges (e.g. small force and high capacity). Since the area that receives the force is large, these sensors are well suited for testing; - soft materials - spherical samples ' To get accurate testing results please apply force on the center of load cell's surface. - Integration into a variety of machine including tactile test system, medical equipment, and press molding equipment - Application in production line including measurement and control of electronic equipment such as mobile phones, battery manufacturing process, etc. - Measurement of gripping force of cabinet drawers, etc._
Open the catalog to page 1IMADA CO., LTD.Flat Type Compression Load Cell CLFX/CFX series Specifications *1 It is the accuracy of the sensor only. Refer to page 3 for the accuracy of combinations with the amplifier (indicator) under [Models of Sensors Combined with Indicators (Separated sensor models)] and [Models of eZ-Connect Series (Sensor Interchangeable Model)]. *2 IP is only approved for the sensor part. The amplifier (indicator), the connector parts, and cable are not secured. *3 Refer to specification of [Options Available for Load cell Cable] to change cable length or so. * An amplifier (indicator) is required...
Open the catalog to page 2IMADA CO., LTD.Flat Type Compression Load Cell CLFX/CFX series [Available Amplifiers (Indicators)] Separated Sensor Model * Refer to the specification sheet of each indicator for details. [Models of Load Cell Only] * When ordering load cell only, select the connector type and add the code to the end of the load cell model; for example, the product model for CLFX-50N with 5 pin is “CLFX-50N-5P”.
Open the catalog to page 3Flat Type Compression Load Cell CLFX/CFX series *1 Total accuracy when combined with the eZ-Connect series amplifier. e.g. Total accuracy of eCLFX and eZT ^ +/-1.2%F.S. or less (Load cell: +/-1.0%F.S. or less + Amplifier: +/-0.2%F.S. or less) * Please refer to the accuracy of the sensor of eZ-Connect in the Specifications table. - Fixing Belt for Operativity Measurement FBO-CFX Product Image -Dedicated fixing belt for CFX series to attach it to your finger or the tool edge -Convenient to measure sample operating force in an actual usage scene -Flexibly usable for testing of samples with unique...
Open the catalog to page 4IMADA CO., LTD.Flat Type Compression Load Cell CLFX/CFX series- Other Load Cells Standard type Features - Available in 4 types; Light, Standard, Professional, and Plus - Plots graphs of force-displacement at real time via USB connection at - Comment function for keeping a note of testing conditions such as testing speed - Overlays up to 5 graphs (Standard and Professional) or 10 graphs (Plus) - Analyzes torque-angle relationships (Professional) * Refer to each specification sheet for further information. *1 The linear scale connection is limited to models equipped with the displacement output...
Open the catalog to page 5IMADA CO., LTD. Flat Type Compression Load Cell CLFX/CFX series [Dimensions] CLFX series CFX series 2-M2 effective 2.5 Same for the other side [Cautions] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various characteristics or safety. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the...
Open the catalog to page 65 Pages
8 Pages
4 Pages
3 Pages
5 Pages
3 Pages
4 Pages
5 Pages
7 Pages
6 Pages
6 Pages
6 Pages
7 Pages
9 Pages
6 Pages
4 Pages
4 Pages
7 Pages
7 Pages
7 Pages
4 Pages
6 Pages
11 Pages
5 Pages
7 Pages
6 Pages
4 Pages
5 Pages
7 Pages
7 Pages
4 Pages
4 Pages
5 Pages
3 Pages
4 Pages
3 Pages
4 Pages
5 Pages
6 Pages
7 Pages
6 Pages
6 Pages
4 Pages
4 Pages
5 Pages
7 Pages
7 Pages
7 Pages
6 Pages
8 Pages
7 Pages
5 Pages
6 Pages
4 Pages
4 Pages
3 Pages
7 Pages
7 Pages
7 Pages
8 Pages
4 Pages
5 Pages
4 Pages
3 Pages
3 Pages
6 Pages
8 Pages
4 Pages
4 Pages
8 Pages
5 Pages
4 Pages
4 Pages
4 Pages
3 Pages
6 Pages
6 Pages
4 Pages
4 Pages
3 Pages
3 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
4 Pages
6 Pages
3 Pages
3 Pages
4 Pages
4 Pages
2 Pages
6 Pages
5 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
6 Pages
5 Pages
3 Pages
4 Pages
5 Pages
5 Pages
5 Pages
3 Pages
5 Pages
4 Pages
4 Pages
5 Pages
1 Page
1 Page
8 Pages
8 Pages
9 Pages
7 Pages
3 Pages
6 Pages
4 Pages
3 Pages
3 Pages
4 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages