1. Catalogs
  2. ILME
  3. 2016 Plugs and sockets for industrial use
video corpo
cad

2016 Plugs and sockets for industrial use
1 /32Pages

2016 Plugs and sockets for industrial use

2016 Plugs and sockets for industrial use
1 /32Pages

Catalog excerpts

2016 Plugs and sockets for industrial use-1

INSTALLATION TECHNOLOGY Plugs and sockets for industrial use

 Open the catalog to page 1
2016 Plugs and sockets for industrial use-2

ON-LINE CONFIGURATOR INSTALLATION TECHNOLOGY Starting from PLUGS & SOCKETS QUICK SEARCH Onink sparrh hy :"r::iurt ITEM CODE TECHNICAL DETAILS Kl Interacted switched sock... Plugs & Sockets - Factory installed ntemcl ■■.vliln;| - Cab r. entry litre; tied tretric Starting from PART NUMBER

 Open the catalog to page 2
2016 Plugs and sockets for industrial use-3

i Sockets for industrial purpose IB6 Series - IP66 degree of protection - mechanical resistance: IK 10 - insulating enclosure - 16A, 32A, 63A models - installation: single wall mount or with FC series - cable entry: top or rear - bottom plug entry - versions: without fuses; with fuses; with transformer SQV/FM Series - IP44/IP55 degree of protection - mechanical resistance: 6 J - insulating enclosure - 16A, 32A models - installation: wall / flush mount - cable entry: top or rear - plug entry 15° angled - versions: without fuses; with fuses; with transformer - IP65 and IP55 degree of protection...

 Open the catalog to page 3
2016 Plugs and sockets for industrial use-4

IP66/IP67 overview of the interlocked switched socket-outlets, in compliance with standard CEI EN 60309-1 e -2 e -4 TM...SIS/KSIS without base box TM...SIS without base box with fuse with fuse TM...SIR without base box TM...SIR/KSIR without base box A with room for modular equipment (rail for 4,5 modules) with room for modular equipment (rail for 4,5 modules) TM...SSP without base box TM...SSP/KSSP without base box A with direct connection with direct connection i For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 4
2016 Plugs and sockets for industrial use-5

CSA= BOTTOM ENTRY INCLINED FLUSH-MOUNTING sockets A screw connection screw connection For technical data-sheet and further information please look at our technical catalogues on website www.ilme.com

 Open the catalog to page 5
2016 Plugs and sockets for industrial use-6

IP66/IP67 overview of the interlocked switched socket-outlets, in compliance with standard CEI EN 60309-1 e -2 e -4 TM...KIS wall mounting (with single box) TM...IS wall mounting (with single box) A with fuse with fuse TM...IR/KIR wall mounting (with single box) 110V TM...IR wall mounting (with single box) with room for modular equipment (rail for 4,5 modules) with room for modular equipment (rail for 6 modules) TM...SP/KSP wall mounting (with single box) TM...SP wall mounting (with single box) A with direct connection with direct connection TM...T1 wall mounting (with single box) i For technical...

 Open the catalog to page 6
2016 Plugs and sockets for industrial use-8

i TM-EX overview of the interlocked switched socket-outlets, in compliance with standard ATEX CEI EN 60079-0 e CEI EN 60079-31 (dust) TM...ISX wall mounting (with single box) A TM...ISX wall mounting (with single box) 230V 32A/63A with fuse II 3D - Ex tc IIIC T65 °C Dc IP66/IP67 X TM...SPX/KSPX wall mounting (with single box) TM...SPX wall mounting (with single box) A 63A with direct connection 16A/32A with direct connection TM...SSPX/KSSPX wall mounting (without single box) TM...SISX wall mounting (without single box) A 16A/32A with direct connection II 3D - Ex tc IIIC T65 °C Dc IP66/IP67 U...

 Open the catalog to page 8
2016 Plugs and sockets for industrial use-9

i For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 9
2016 Plugs and sockets for industrial use-10

overview of the interlocked switched socket-outlets, in compliance with transformer For technical data-sheet and further informatio

 Open the catalog to page 10
2016 Plugs and sockets for industrial use-11

i For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 11
2016 Plugs and sockets for industrial use-12

i For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 12
2016 Plugs and sockets for industrial use-13

interlocked switched socket-outlets types, in compliance with standard CEI EN 60309-1 e -2 e -4 PK...PB5 sockets metal enclosures 110V PK...PE5 sockets metal enclosures with fuse with direct connection with fuse with direct connection PB...A1/A2 sockets metal enclosures PK...LL sockets metal enclosures A sockets with micro circuit breaker i 11 For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 13
2016 Plugs and sockets for industrial use-14

i SQV overview of the interlocked switched socket-outlets, in compliance with standard CEI EN 60309-1 e -2 e -4 SQV to be mounted in single or multiple boxes 110V SQV to be mounted in single or multiple boxes with fuse with fuse SQ to be mounted in single or multiple boxes 110V SQT to be mounted in single or multiple boxes with transformer with direct connection SQE to be mounted in single or multiple boxes A SQE to be mounted in single or multiple boxes 400V IP44 16A/32A with direct connection IP55 16A/32A with direct connection i For technical data-sheet and further information please check...

 Open the catalog to page 14
2016 Plugs and sockets for industrial use-15

i FM distribution system for sockets SQV i 13 For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 15
2016 Plugs and sockets for industrial use-16

i BK IP66/IP67 distribution system for utilities, in compliance with standard CEI EN 60309-1 e -2 e -4 BK to be mounted in single or multiple boxes BE to be mounted in single or multiple boxes A with direct connection with fuse carrier BPR to be mounted in single or multiple boxes A BP to be mounted in single or multiple boxes 400V cover with socket and window for modular cover with socket BT to be mounted in single or multiple boxes A BK Series - IP66/IP67 degree of protection - mechanical resistance: IK 10 - UL 94 V0 insulating enclosure - 16A, 32A, 63A models - installation: wall / flush mount...

 Open the catalog to page 16
2016 Plugs and sockets for industrial use-17

i BC IP66/IP67 distribution system for utilities For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 17
2016 Plugs and sockets for industrial use-18

i QC factory assembled board for construction sites (ACS) with sockets-outlet TM and SQV series, QC with sockets SQV series with fuse holder QM with IP55 SCHUKO® SOCKETS (ACCORDING TO EN 60529) maximum withdrawable active power values kW magnetothermal main switch with differential protection A QP SQ A series with fuse holder maximum withdrawable active power values magnetothermal main switch with differential protection in compliance with standard CEI EN 61439-4 i For technical data-sheet and further information please check our technical catalogues at www.ilme.com

 Open the catalog to page 18
2016 Plugs and sockets for industrial use-19

front back QM with 2 SQ type SQE socket-outlets For technical data-sheet and further information please check our technical catalogues at www.ilme.com plug entry maximum withdrawable active power values maximum withdrawable active power values magnetothermal main switch with differential protection maximum withdrawable active power values plug entry plug entry QM with 4 PEW...PQ/PQF socket-outlets magnetothermal main switch with differential protection magnetothermal main switch with differential protection QM factory assembled board for construction sites (ACS), in compliance with standard CEI...

 Open the catalog to page 19
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.