DPX Progressive dividers High quality and High tolerance Unbeatable combination of performance and convenience
Open the catalog to page 1Benefits and Technical data 4 Blocks ordering codes 8 Elements ordering codes 9 Cycle control (ATEX) 15 Pressure sensor & bridge junction 17
Open the catalog to page 2Features and general description The DPX system doses lubricant with a progressive piston movement. Every piston controls the following one in a sequence obtained through a single delivery flow. This system is highly qualified for dosing oil and grease to one or more journals or bearing. Each piston is in series with the component before or the one after it and therefore malfunctioning of one of these causes stopping of the sequence and consequently inhibiting of the system. This inhibition occurs also during any external clogging or when unused outlet are plugged. In order to check the...
Open the catalog to page 3Technical data Positive discharge of measured quantity of lubricant guaranteed Suitable for system functioning control Long operational life assured by a careful selection of high grade material and strict quality control. Operation monitor with indicators and/or contact plugs system design flexibility due to large range and combination of sizes I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.iiciube.com - inFo@ilclube.it
Open the catalog to page 4Lubricant flow pressure (blue) moves piston 1 to the left allowing lubricant discharge (giallo) from B. When piston 1 reaches its limit, lubricant flow pressure (blue) operates on piston 2. Lubricant volume (yellow) discharge from C. When piston 2 reaches its limit, lubricant flow pressure (blue) operates on piston 3. Lubricant volume (yellow) discharge from E. I.L.C. srl - Via Garibaldi, 149 - 20155 Gorla Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 5When piston 3 reaches its limit, lubricant flow pressure (blue) operates on piston 1. Lubricant volume (yellow) discharge from A. When piston 1 reaches its limit, lubricant flow pressure (blue) operates on piston 2. Lubricant volume (yellow) discharge from D. When piston 2 reaches its limit, lubricant flow pressure (blue) operates on piston 3. Lubricant volume (yellow) discharge from F. The system is ready for a new cycle. I.L.C. srl - Via Garibaldi, 149 - 20155 Gorla Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 6Outlets union/separation Each divider piston is arranged in order to feed 1 or 2 outlets. When the separation dowel is inserted (see Fig.1), the discharge is carried out in both sides. When the dowel is not inserted (see Fig. 2), the double discharge is carried out in one of the two available outlets. If it is necessary to use a single outlet, extract the sphere (A92.089005), besides the separation dowel (UNI5925D M4X6) and insert a plug (A73.087010 + A92.127006) in the outlet no more used. The dividers are supplied with the separation dowel inserted and the two outlets open as standard....
Open the catalog to page 7Blocks ordering codesBlocks ordering codes Pistons I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.iiciube.com - info@ilclube.it
Open the catalog to page 8Elements ordering codes Standard With inductive sensor (cabled) I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 9Elements ordering codesWith induvtive sensor M8 Discharge I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 10Elements ordering codesCon Micro switch Discharge Tie-rods ordering codes Elements I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 11Junctions & filters DPX Banjo with grease nipple 03.355.5/03.355.6 Inset filter Banjo junctions are placed on a progressive distributor inset. Their job is to let us use a manual or hidrau-lic pump when the main pump does not work. These strainer prevent the lubricant lines from being obstructed by impurities. Supply joints included. Plug 1/4" BSP (F) 07.270.5 These strainer prevent the lurbricant lines from being obstructed by impurities. Filtration rate 70 p Plug 1/4" BSP (F) I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 -...
Open the catalog to page 12Cycle control Micro switch 49.050.2 SHUT OFF valves EV-2 are made of a special "NC" 2-ways solenoid valve and of a modular base that can be directly assembled on the DPL inlet. EV-2 valve is the essential element in order to transforma a standard progressive system into a sectioned system. Micro switch Ordering codes Electrical connection Pistons I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.iiciube.com - info@ilclube.it
Open the catalog to page 13Cycle control DPX Visual pin The visual pin shows the piston movement, monitoring the proper operation of the entire system. In this control a proximity switch is housed in a composite block. The piston opens and closes the contact as it moves into its operational seat. They are usually used in cycle control systems where they can count up to 300 movement for minute. Electrical data I.L.C. srl - Via Garibaldi, 149 - 20155 Goria Minore - Italy Phone +39 0331 601697 - Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it
Open the catalog to page 14Cycle control (ATEX)Group II Category 1D-1G/2G Electrical data Electrical Model Certified intrinsically safe cir cuits with maximum values U= 15 V / I = 50 mA/ P = 120 mW Nominal voltage 8,2 DC; (1kQ) Voltage V 7,5...30 DC; to be used out side potentially explosive areas Current < 1 blocker; (> 2,1 mA condut- tore) Contact NC Current capacity [MA] < 30; to be used outside poten tially explosive areas Temperature -20...70 Group II Category 3G-3D Electrical data Electrical Model Nominal voltage Outlet current Sensor housing Stainless steel Ordering codes Electrical...
Open the catalog to page 15All I.L.C. srl catalogs and technical brochures
-
PEGPEO
39 Pages
-
PEG250N
12 Pages
-
MPO
6 Pages
-
PPFG
6 Pages
-
DR-DF valves Catalogue
11 Pages
-
VOLUMETRIC SYSTEM
74 Pages
-
FITTING AND ACCESSORIES
57 Pages
-
AGRICULTURAL MACHINERY LUBRICATION
104 Pages
-
VEHICLES LUBRICATION
80 Pages
-
AIR/OIL LUBRICATION
36 Pages
-
MINIMAL LUBRICATION
107 Pages
-
PROGRESSIVE SYSTEMS
153 Pages
-
VOLUMETRIC SYSTEMS
83 Pages
-
RESISTANCE SYSTEMS
45 Pages
-
CATOALOG
66 Pages