HF532

HF532
1 / 12 PagesView full catalog

HF532

Product catalog summary
Specifications:
- Maximum Working Pressure: 8 bar [116 psi]
- Testing Pressure: 12 bar [175 psi]
- Burst Pressure: 16 bar [230 psi]
- Element Collapse Pressure Rating (ISO 2941): 10 bar [145 psi]
- Materials: Conductive nylon body, reinforced nylon bowl, Buna and Viton seals, zinc-plated steel end caps and inner tube
- Filter Media: Microfiber (FG010 10 µm, FG025 25 µm), Antistatic Microfiber (AF010 10 µm, AF025 25 µm)
- Operating Temperature: Buna -30 to 90 °C [-22 to 195 °F], Viton -20 to 110 °C [-4 to 230 °F]
- Maximum Flow: 50 l/min [13 gpm]
- Fluids Compatibility (ISO 2943): Mineral oils, water emulsions, glycol water, synthetic fluids
- By-pass Valve Activation Differential Pressure Setting: 1.7 bar - 3.5 bar [25 psi - 51 psi]
Technical Features:
- Tank top filters for circuit return line protection
- 360° adjustable connection
- Use of "AF" microfiber and conductive plastics to minimize electric discharge risk
- Wide range of accessories and clogging indicators available
Operating Instructions:
1. Check filter integrity.
2. Remove protection cap from inlet port.
3. Secure filter to tank using flange holes with 5 Nm torque.
4. Connect return pipes to inlet port with hose clamp.
5. If applicable, install clogging indicator with 30 Nm torque.
6. Start circuit and check for leaks.
7. For element replacement, stop machine, secure valves, remove cover, replace element, and reassemble.
Assembly and Replacement:
- Follow specific steps for assembly and element replacement to ensure proper function and avoid leaks.
Build Your Filter:
- Options for filter type, dimension, filtration degree, by-pass valve setting, seals, indicator ports, and accessories are available for customization.
Notes:
- For special requests, contact the sales department.
See more

Catalog excerpts

HF532-1

RETURN FILTERS ELEMENT COLLAPSE PRESSURE RATING (ISO 2941) MATERIALS BODY Conductive nylon Reinforced nylon Buna Zinc-plated steel INNER TUBE Zinc-plated steel FILTER MEDIA MICROFIBER ANTISTATIC MICROFIBER OPERATING TEMPERATURE BUNA BY-PASS VALVE ACTIVATION DIFFERENTIAL PRESSURE SETTING FLUIDS COMPATIBILITY - ISO 2943 (N. ISO 6743/4) MINERAL OILS (1) HFAE - HFAS HS - HFDR - HFDU - HFDS (1) With Buna seals (2) With Viton seals TECHNICAL FEATURES ●● Tank top filters to protect the circuit return line flows ●● 360° adjustable connection ●● "AF" microfiber and conductive plastics media to minimize the risk of electric discharges inside the element ●● Wide range of accessories and clogging indicators (3) Without zinc-plated elements

 Open the catalog to page 1
HF532-2

HF532 PRESSURE DROP CURVES HF532-10.062 BY-PASS VALVE PRESSURE DROP CURVE flow (l/min) ►►Curves determined under the following conditions: SAE10 mineral oil - 30 cSt kinematic viscosity - 0,856 kg/dm3 density

 Open the catalog to page 2
HF532-3

HF532 FLOWS CHART INLET FILTER TYPE Hose adaptor

 Open the catalog to page 3
HF532-4

TANK HOLE FILTER TYPE

 Open the catalog to page 4
HF532-5

HF532 HEK02 FILTER ELEMENT DIMENSIONS ELEMENT TYPE ACCESSORIES BOWL EXTENSION LEVEL DIPSTICK ►►Specify bowl extension and level dipstick length when ordering

 Open the catalog to page 5
HF532-6

OPERATING INSTRUCTIONS ASSEMBLY ELEMENT REPLACEMENT After checking the integrity of the filter inside its package, proceed as follows: ●● Take the protection cap off the inlet port. ●● Ensure the filter to the tank through the flange holes by using a torque of 5 Nm. ●● Connect the circuit return pipes to the inlet port with the appropriate hose clamp. ●● If the filter has a clogging indicator, take the protection cap off and screw the indicator into the dedicated seat to a torque of 30 Nm. ●● Start the circuit for a few minutes. ●● Make sure there are no leaks. Proceed as follows: ●● Stop the...

 Open the catalog to page 6
HF532-7

HF532 BUILD YOUR FILTER Write here ↓↓↓ 1 FILTER TYPE Rear manometer Visual indicator Electrical indicator Bowl extension (choose length) Level dipstick (choose length) FILTER SURFACE Standard FILTRATION DEGREE BY-PASS VALVE INLET Ø 19,5 mm hose adaptor INDICATOR PORTS INDICATOR THREAD

 Open the catalog to page 7
HF532-8

BUILD YOUR FILTER ELEMENT Write here ↓↓↓ 1 ELEMENT TYPE FILTER SURFACE Standard FILTRATION DEGREE VERSION With valve and spring Without valve and spring BY-PASS VALVE ●: only combination available ►►For special requests please c

 Open the catalog to page 8
HF532-12

RETURN FILTERS HF 502/508 HF 532 HF 547 HF 554 HF 570/575/578 SPIN-ON FILTERS HF 620/625 HF 650 MEDIUM AND HIGH PRESSURE FILTERS HF 690 HF 705 HF 710 HF 725 HF 731 HF 735 HF 741 HF 745 HF 749 HF 760 HAND PUMPS EP ACCESSORIES HB 02/50/70/110/120 AF 105/106 HL 91 INDICATORI DI INTASAMENTO FLUX OIL IK 15/50 R 15/50 Via C. Prampolini, 2 43044 Lemignano di Collecchio Parma - Italy Phone: +39 0521 304911 [email protected] www.ikron.it