video corpo

ROTARY EVAPORATORS I SETUP SOLUTIONS
8Pages

{{requestButtons}}

Catalog excerpts

ROTARY EVAPORATORS I SETUP SOLUTIONS - 1

ROTARY EVAPORATORS I SETUP SOLUTIONS

Open the catalog to page 1
ROTARY EVAPORATORS I SETUP SOLUTIONS - 2

Choose your setup /// Rotary evaporators and peripheral devices from a single source IKA's rotary evaporator's award winning design and performance will make a significant difference in your laboratory. The IKA range of RV 3, RV 8, RV 10 digital, RV 10 auto and RV 10 auto pro rotary evaporators offers excellent distilling solutions to the demanding user. Value for money, design and technology – all for your convenience! Depending on your application a vacuum system (pump / controller / valve) and cooling is required to get everything out of your distillation. The powerful vacuum pumps...

Open the catalog to page 2
ROTARY EVAPORATORS I SETUP SOLUTIONS - 3

Step 1: Base unit With selection of the base unit, consisting of heating bath, lift and piston drive, you define the maximum evaporation temperature, essential safety features as well as ease of use and degree of automation of your system. the ideal entry-level model semi-automated models for standard evaporating applications RV 10 series the digital and most automated models for demanding and frequent distilling Motor lift Safety lift-out function Speed display Max. heating bath temperature Integrated vacuum controller yes / ON-OFF valve vacuum regulation yes / automatic boiling point...

Open the catalog to page 3
ROTARY EVAPORATORS I SETUP SOLUTIONS - 4

Step 2: Vacuum solution The result of a distillation is significantly influenced by the used vacuum system. IKA offers various vacuum solutions that perfectly match to the rotary evaporators. The portfolio includes pumps with and without integrated vacuum control as well as speed-controlled pumps and pumps with fixed speed. The degree of automation of the complete system can be influenced by the selection of the vacuum solution. For example, a speed-controlled pump with controller enables automatic boiling point detection. Cleaning function of valves for long service life Universal vacuum...

Open the catalog to page 4
ROTARY EVAPORATORS I SETUP SOLUTIONS - 5

Step 3: Recirculating chiller In order to select the right chiller, the following parameters are important: size of the evaporation flask, number of rotary evaporators that are to be supplied with one chiller, requirements for flow or condensate temperature. On this basis, the cooling power requirement can be determined and the right cooling source can be selected. The decision for a recirculationg chiller from IKA is also the decision for high energy savings and reduction of operating noises. Greatest power density in its class Evaporation flask size* Number of rotary evaporators* Cooling...

Open the catalog to page 5
ROTARY EVAPORATORS I SETUP SOLUTIONS - 6

Step 4: Selected accessories Are you interested in configuring your Depending on the base unit and the matching peripheral devices, IKA is offering many different accessories to complete your setup. Further accessories are available on www.ika.com. personal set-up? Contact our sales team to receive your individual offer. sales@ika.de // +49 7633 831-140 Vertical condenser with enlarged surface, coated Ident. No. 0020019654 Evaporation flask, coated, NS 29/32, 500 ml Ident. No. 0020005333 Protection cover for the heating baths HB eco and HB digital Ident. No. 0020024125 Stand pole for...

Open the catalog to page 6
ROTARY EVAPORATORS I SETUP SOLUTIONS - 7

RV 10 auto pro V-C Complete Package /// The complete solution for your rotary evaporator setup With the new package, IKA is offering a complete solution at an attractive price. All components and connections required for operation are included in the package and come from the same manufacturer. In the event of queries or service cases IKA is your competent contact for the whole setup. The RV 10 auto offers all characteristics required for efficient, safe, and cost-effective operation. Safety is ensured by the coated glassware which protects the user in case of glass breakage. The included...

Open the catalog to page 7
ROTARY EVAPORATORS I SETUP SOLUTIONS - 8

Set-up solutions for two or more rotary evaporators With only one vacuum system and chiller, multiple rotary evaporators can be supplied. The following examples shows possible solutions for the set-up of a complete system including rotary evaporators with suitable vacuum and cooling system. Example 1: Two rotary evaporators The system consists of: 1 1 2 × RV 8 V-C rotary evaporator 2 × RV 8.3 stand pole 2 × VC 10 vacuum controller 2 × VC 10.300 check valve 1 × VACSTAR digital vacuum pump 1 × VSE 1 vacuum safety emmission 1 × RC 2 GREEN basic recirculating chiller 2 × RV 10.5005 set of hoses...

Open the catalog to page 8

All IKA catalogs and technical brochures

  1. Centrifuges

    6 Pages

  2. IKA G-L

    4 Pages

  3. Calorimeters

    19 Pages

  4. IKA MATRIX

    4 Pages

  5. VACSTAR

    4 Pages

  6. Starvisc

    4 Pages

  7. IKA [scale]

    2 Pages

  8. IKA Oven 125

    6 Pages

  9. IKA myPlate

    2 Pages

  10. Dry Mills

    21 Pages

  11. Shakers

    35 Pages

  12. Installations

    25 Pages

  13. Pilotes

    24 Pages