Overview: The document provides a decision-making matrix for selecting band heaters, highlighting their specifications, features, and operational parameters. It includes various types of band heaters with distinct characteristics suitable for different industrial applications.
Specifications:
  • Operating Temperature: Ranges from 280°C to 550°C depending on the heater type.
  • Jacket Material: Options include aluminium, stainless steel, and hot-dip aluminised steel sheet.
  • Voltage: Standard operating voltage is 230-250V, with variations for specific models.
  • Max Load: Varies from 3.5 W/cm² to 6.5 W/cm².
  • Wall Thickness: Ranges from ~3.5 mm to ~20 mm.
Features:
  • Heaters are available in one-piece and multi-piece executions, with dimensions specified for each type.
  • Clamp gaps and lock types vary, with options for disc spring locks and pressure spring locks.
  • Spreadability and connection options are detailed, including axial, radial, and tangential lead exits.
  • Integral temperature sensors are available in types L, J, K, and Pt 100.
Applications:
  • Suitable for injection moulding and extrusion processes.
  • Designed for fast reaction and high load capacity with low storing effect.
  • Options for mineral or ceramic isolation for enhanced performance.
Additional Information:
  • Custom dimensions and loads are available upon request.
  • Warning signs for hot surfaces are included for safety.
See more

Catalog excerpts

Band Heater decision making matrix-1

DECISION-MAKING MATRIX BAND HEATERS ZAK special features max. operating temperature jacket material stiff, efficient Aluminium compact Band Heaters with uniform heat course for superior geomtry fast reacting, high loadable, mineral-/ or ceramic isolated contact heater with low storing effect electric robust, ceramic isolted radiate Heater with storing effect mica isolated standard Band Heater for injection mould and extrusion Heater: Aluminium clamp band: stainless steel or FAL stainless steel hot-dip aluminised steel sheet FAL standard operating voltage star 230/400V delta 3x400V wall thickness multi-piece execution standard clamp gap clamp lock spreadability connection caps with solit leads (max. 17,4 A at 230V) 6 /8 /12 mm (x-dependent) clamp loops from Ø 120 mm disc spring lock (TFV) from Ø 100 mm with 2-parted internal band ~ 6 mm clamp loops from Ø 200 mm disc spring locks (TFV) possible axial A or S radial B tangential C until Ø 399 mm clamp loops from Ø 400 mm pressure spring locks (DFV) from Ø 100 mm with 2-parted internal band axial A or S radial B, tangential C (max. 8 A at 230V) axial A radial B tangential C contact fitting (3-pin) max. 16A/230V plug direction cable fitting max. 16 - 30A direction of lead exit axial A radial B tangential C lead execution holes / cutouts metal braided leads until 250 °C, GLS type 600 until 600 °C type: L, J, K particularly suitable for superior geomtry metal braided leads until 250 °C type: L, J, K, and Pt 100 as per preset dimensions possible thermocouple connector warning sign „hot surface“ subjet to technical change - other dimensions and loads available on request - for more details see as well our technical data