Catalog excerpts
Spindle cables/Single cores CF885 PVC Medium voltage cables CFCRANE.PUR pur V 10 -20/+80 36 month chainflex® guarantee Guaranteed lifetime for predictable reliability ► Selection table page 288 With the help of the chainflex® service life calculator, you can quickly and easily calculate the expected service life of chainflex® cables specifically for your application:
Open the catalog to page 1chainflex® cable Guaranteed lifetime Minimum bend radius [factor x d] Minimum bend radius [factor x d] Minimum bend radius [factor x d] Motor cables 5 million (1 million) double strokes * 7.5 million (3 million) double strokes * 10 million (5 million) double strokes * (1) Exclusive! Guaranteed lifetime for this series according to the guarantee conditions ► Page 22-23 * Higher number of double strokes? Online lifetime calculation ► www.igus.eu/chainflexlife Figures in brackets refer to chainflex® series CF885/CF886 and CF895/CF896
Open the catalog to page 2chainflex® cable Minimum bend radius [factor x d] Minimum bend radius [factor x d] Minimum bend radius [factor x d] Spindle cables/Single cores 5 million (1 million) double strokes * 7.5 million (3 million) double strokes * 10 million (5 million) double strokes * > Exclusive! Guaranteed lifetime for this series according to the guarantee conditions ► Page 22-23 * Higher number of double strokes? Online lifetime calculation ► www.igus.eu/chainflexlife Figures in brackets refer to chainflex® series CF885 and CF886
Open the catalog to page 3Motor cable | PVC | chainflex® CF885 Class 3.1.1.1 Basic requirements Travel distance Oil resistance Torsion Flame retardant • For flexing applications • PVC outer jacket • Flame retardant ER[Cp Bend radius Conductor Core insulation Core structure Core identification Outer jacket e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported minimum 15 x d minimum 12 x d minimum 8 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 3 m/s Unsupported travel distances up to 10 m, Class 1 Conductor consisting of bare...
Open the catalog to page 4Motor cable | PVC | chainflex® CF886 Class 3.1.1.1 Basic requirements Travel distance Oil resistance Torsion Flame retardant • For flexing applications • PVC outer jacket • Shielded • Flame retardant ER[Cp Bend radius Conductor Core insulation Core structure Core identification Overall shield Outer jacket Nominal voltage Testing voltage e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported minimum 15 x d minimum 12 x d minimum 8 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 3 m/s Unsupported travel...
Open the catalog to page 5Motor cable | PVC | chainflex® CF210.UL Class 4.2.2.1 Basic requirements Travel distance Oil resistance Torsion none mT3T highest none |1 | 2 | 3 | 4 ±360° • For medium duty applications • Flame retardant• PVC outer jacket • Shielded • Oil-resistant oil Flame retardant Bend radius Conductor Core insulation Core structure Core identification Intermediate layer Overall shield Outer jacket e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported gliding 50 m/s2 minimum 10 x d minimum 8 x d minimum 5 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C...
Open the catalog to page 6Motor cable | PVC | chainflex® CF30 Class 5.5.2.2 Basic requirements Travel distance Oil resistance Torsion low |1 | 2 13 14 MeT7 highest unsupported |1 | 2 | 3 m > 400 none mT3T highest Properties and approvals UV resistance uv Oil resistance • For heavy duty applications • PVC outer jacket • Oil-resistant • Flame retardant Optimised core insulation ^ Flame retardant 0 Silicone-free UL/CSA Dynamic information Bend radius Cable structure Conductor Core insulation Core structure Core identification Outer jacket CFRIP® Electrical information Nominal voltage 7U Testing voltage e-chain® linear...
Open the catalog to page 7Motor cable | PVC | chainflex® CF30 Class 5.5.2.2 Strip cables 50% faster igus chain flex"' CF30 Example image Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core 300 EPLAN download, configurators ► www.igus.eu/CF30
Open the catalog to page 8Motor cable | PVC | chainflex® CF31 Class 5.5.2.1 Basic requirements low ME highest Oil resistance none highest • For heavy duty applications • PVC outer jacket • Shielded • Oil-resistant • Flame retardant Optimised core insulation ^ Flame retardant 0 Silicone-free Dynamic information Bend radius Temperature v max. a max. Travel distance e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported gliding 80 m/s2 minimum 7.5 x d minimum 6 x d minimum 4 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 10 m/s 5...
Open the catalog to page 9Motor cable | PVC | chainflex CF31 Basic requirements Travel distance Oil resistance Torsion low unsupported none none Strip cables 50% faster Example image Number of cores and conductor nominal cross section Copper index Order example: CF31.15.04 – to your desired length (0.5 m steps) CF31 chainflex® series .15 Code nominal cross section .04 Number of cores Online order www.chainflex.eu/CF31 Delivery time 24hrs or today. Delivery time means time until goods are shipped. month guarantee EPLAN download, configurators www.igus.eu/CF31 Note: The given outer diameters are maximum values and...
Open the catalog to page 10Motor cable | iguPUR | chainflex® CF895 Class 3.1.3.1 Basic requirements low m highest Oil resistance none H highest • For flexing applications • iguPUR outer jacket • Oil-resistant • Flame retardant Flame retardant Bend radius Conductor Core insulation Core structure Core identification Outer jacket e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported minimum 15 x d minimum 12 x d minimum 8 x d -20 °C up to +80 °C -40 °C up to +80 °C (following DIN EN 60811-504) -50 °C up to +80 °C (following DIN EN 50305) 3 m/s Unsupported travel distances up to 10 m, Class 1...
Open the catalog to page 11All Igus® catalogs and technical brochures
-
chainflex® CFSPECIAL.572
1 Pages
-
chainflex® CFSPECIAL.192
1 Pages
-
chainflex® CF31
6 Pages
-
triflex® TRLF
2 Pages
-
iglidur® PRT
4 Pages
-
ECS catalogue 2019
675 Pages
-
Control cables
36 Pages
-
Special cables
9 Pages
-
igus connectors
27 Pages
-
Camera
7 Pages
-
Robot
20 Pages
-
Fibre optic cables
11 Pages
-
Drive technology
87 Pages
-
CF.INI
9 Pages
-
Network cables
19 Pages
-
Servo cables
18 Pages
-
data cables
20 Pages
-
News- moving energy made easy
131 Pages
-
drive technology - readycable
85 Pages
-
Industry broschure: Fitness
24 Pages
-
vector_award_2018
180 Pages
-
News2018_e_ketten
66 Pages
-
News2018_dry_tech
89 Pages
-
EU_igus_robotics
110 Pages
-
EU_dry-tech_bearings_web
775 Pages
-
EU_chainflex_catalogue_web
416 Pages
-
e_chain_catalog_EN
1138 Pages
-
EN-DE_News2017_robolink_web
14 Pages
-
EU_industry-tyre
13 Pages
-
EU_CP_industry_solar
15 Pages
-
EU_brochure_3Dprint_web
21 Pages
-
EN_industry_woodworking
11 Pages
-
EN_industry_prostheses
9 Pages
-
EN_industry_packaging
33 Pages
-
EN_industry_medical
15 Pages
-
EN_industry_maritime
27 Pages
-
EN_Industry_MachineTools
25 Pages
-
EN_Industry_agriculture_web
17 Pages
-
EU_industry_bike_web
15 Pages
-
Industry brochure: 3D printing
21 Pages
-
Shore power
2 Pages
-
chainflex® Torsion Cables
18 Pages
-
chainflex® Video, vision, bus
15 Pages
-
chainflex® Special Cables
8 Pages