Control cables
36Pages

{{requestButtons}}

Catalog excerpts

Control cables - 1

Control cables 36 month chainflex® guarantee Guaranteed lifetime for predictable reliability ► Selection table page 46 With the help of the chainflex® service life calculator, you can quickly and easily calculate the expected service life of chainflex® cables specifically for your application:

Open the catalog to page 1
Control cables - 2

chainflex® cable Minimum bend radius [factor x d] < 10 m > 10 m Minimum bend radius [factor x d] < 10 m > 10 m Minimum bend radius [factor x d] < 10 m > 10 m Control cables 5 million (1 millioi double strokes ’ 7.5 million (3 millic double strokes 10 million (5 millio double strokes (1) Exclusive! Guaranteed lifetime for this series according to the guarantee conditions ► Page 22-23 * Higher number of double strokes? Online lifetime calculation ► www.igus.eu/chainflexlife Figures in brackets refer to chainflex® series CF880/CF881 and CF890/CF891

Open the catalog to page 2
Control cables - 3

Control cable | PVC | chainflex® CF880 Class 3.1.1.1 Basic requirements Travel distance Oil resistance Torsion ^ Flame retardant 0 Silicone-free • For flexing applications • PVC outer jacket • Flame retardant Dynamic information Bend radius Cable structure Conductor Core insulation Core structure Core identification Outer jacket Electrical information Nominal voltage Testing voltage e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported minimum 12.5 x d minimum 10 x d minimum 7 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C...

Open the catalog to page 3
Control cables - 4

Control cable | PVC | chainflex CF880 Basic requirements Travel distance Oil resistance Torsion low unsupported none none Example image Number of cores and conductor nominal cross section Copper index Number of cores and onductor c nominal cross section Copper index P hase-out model Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core month guarantee Order example: CF880.07.03 – to your desired length (0.5 m steps) CF880 chainflex® series .07 Code nominal cross section .03 Number of cores...

Open the catalog to page 4
Control cables - 5

Control cable | PVC | chainflex® CF881 Class 3.1.1.1 Basic requirements Travel distance Oil resistance Torsion ^ Flame retardant 0 Silicone-free • For flexing applications • PVC outer jacket • Shielded • Flame retardant Dynamic information Bend radius Cable structure Conductor Core insulation Core structure Core identification Overall shield Outer jacket Electrical information Nominal voltage Testing voltage e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported minimum 12.5 x d minimum 10 x d minimum 7 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN...

Open the catalog to page 5
Control cables - 6

Control cable | PVC | chainflex CF881 Basic requirements Travel distance Oil resistance Torsion low unsupported none none Example image Number of cores and conductor nominal cross section Copper index Order example: CF881.25.25 – to your desired length (0.5 m steps) CF881 chainflex® series .25 Code nominal cross section .25 Number of cores Online order www.chainflex.eu/CF881 Delivery time 24hrs or today. Delivery time means time until goods are shipped. month guarantee EPLAN download, configurators www.igus.eu/CF881 P hase-out model Note: The given outer diameters are maximum values and may...

Open the catalog to page 6
Control cables - 7

Control cable | PVC | chainflex® CF130.UL Class 4.4.1.2 Basic requirements Travel distance Oil resistance Torsion ^ Flame retardant 0 Silicone-free • For medium duty applications • PVC outer jacket • Flame retardant UL/CSA Bend radius e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported gliding 20 m/s2 minimum 7.5 x d minimum 6 x d minimum 4 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 3 m/s 2 m/s Unsupported travels and up to 50 m for gliding applications, Class 4 ± 90°, with 1 m cable length, Class...

Open the catalog to page 7
Control cables - 8

CF130.10.02.UL CF130.10.03.UL CF130.10.04.UL CF130.10.05.UL CF130.10.07.UL CF130.10.12.UL CF130.10.18.UL CF130.10.25.UL Note: The given outer diameters are G = with green-yellow earth core x : Order example: CF130.05.02.UL - to your desired length (0.5 m steps) CF130.UL chainflex® series .05 Code nominal cross section .02 Number of cores Online order ► www.chainflex.eu/CF130.UL Delivery time 24hrs or today. Delivery time means time until goods are shipped.

Open the catalog to page 8
Control cables - 9

Control cable | PVC | chainflex® CF140.UL Class 4.4.1.1 Basic requirements Travel distance Oil resistance Torsion ^ Flame retardant 0 Silicone-free • For medium duty applications • PVC outer jacket • Shielded • Flame retardant Bend radius Conductor Core insulation Core structure Core identification Inner jacket Overall shield Outer jacket e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported gliding 20 m/s2 minimum 7.5 x d minimum 6 x d minimum 4 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 3 m/s 2...

Open the catalog to page 9
Control cables - 10

Control cable | PVC | chainflex® CF140.UL Class 4.4.1.1 Basic requirements low Travel distance unsupported Oil resistance none Torsion none Strip cables 50% faster Part No. Order example: CF140.02.12.UL - to your desired length (0.5 m steps) CF140.UL chainflex® series .02 Code nominal cross section .12 Number of cores Online order ► www.chainflex.eu/CF140.UL Delivery time 24hrs or today. Delivery time means time until goods are shipped. r+p 17) When using the cables with "7G1 Note: The given outer diameters are G = with green-yellow earth core x : 5 mm2" and "7G2.5 mm2" minimum bend radius...

Open the catalog to page 10
Control cables - 11

PVC Control cable | PVC | chainflex® CF5 Class 5.5.2.2 Basic requirements Travel distance Oil resistance Torsion low |1 | 2 13 14 MeT7 highest unsupported |1 | 2 | 3 m > 400 none mT3T highest • For heavy duty applications • PVC outer jacket • Oil-resistant • Flame retardant Dynamic information Bend radius e-chain® linear flexible fixed e-chain® linear flexible fixed unsupported gliding 80 m/s2 minimum 6.8 x d minimum 5 x d minimum 4 x d +5 °C up to +70 °C -5 °C up to +70 °C (following DIN EN 60811-504) -15 °C up to +70 °C (following DIN EN 50305) 10 m/s 5 m/s Unsupported travels and up to...

Open the catalog to page 11

All Igus® catalogs and technical brochures

  1. Camera

    7 Pages

  2. Robot

    20 Pages

  3. CF.INI

    9 Pages

  4. Network cables

    19 Pages

  5. Motor cables

    33 Pages

  6. Servo cables

    18 Pages

  7. data cables

    20 Pages

  8. Shore power