The right choice for your application. Level sensors from ifm.
28Pages

{{requestButtons}}

Catalog excerpts

The right choice for your application. Level sensors from ifm. - 1

The right choice for your application. Level sensors from ifm. Process sensors

Open the catalog to page 1
The right choice for your application. Level sensors from ifm. - 2

Systems for level monitoring. The optimum solution for every requirement. Impedance spectroscopy in contact with the medium For applications on hydraulic and coolant tanks For industrial and hygienic applications Hydrostatic in contact with the medium For industrial and hygienic applications on tanks and in freeflowing waterways Ultrasonic without contact For long distances and difficult surfaces Photoelectric without contact For the detection through non-metallic tank walls Guided wave radar in contact with the medium e choice? Even mor icles at More art .com www.ifm For overflow...

Open the catalog to page 2
The right choice for your application. Level sensors from ifm. - 4

Impedance spectroscopy. The alternative to tuning forks. Suppression of residues and foam. Reliable detection Suppression of residues, splashing water or foam. Better than a tuning fork: Adaptable using IO-Link: More transparency Hygienic design: Type LMC level sensors Flexible mounting thanks to orientation-independent installation. Shock and vibration resistant in a robust stainless steel housing Complementary switching outputs. A thread at the back permits variable insertion depths. Process connection

Open the catalog to page 4
The right choice for your application. Level sensors from ifm. - 5

For industrial applications For hygienic areas and viscous media Type LMC with a thread at the back. Process connection Type LMT level sensors Flexible mounting thanks to orientation-independent installation. Shock and vibration resistant in a robust stainless steel housing. Hygienic approvals EHEDG, 3A and FDA. Versions available as overflow prevention to WHG*. Complementary switching outputs. Preset to aqueous media G 1/2 11 LMT100 LMT191 G 1/2 38 LMT102 LMT192 * German Federal Water Act

Open the catalog to page 5
The right choice for your application. Level sensors from ifm. - 6

Ready in no time. Easy mounting adjustment. Capacitive. For overflow prevention and leakage monitoring. Type LI point level sensors Optimised for use in hydraulic oils and coolants. Modular mounting concept for flexible use. It only takes one push of a button to adjust and set the output function. Normally closed / normally open programmable. Clearly visible indication of the switch points. Approval as overflow prevention or leakage sensor to WHG*. 1 switching output, normally closed in connection with climatic tube see accessories page 27 * German Federal Water Act

Open the catalog to page 6
The right choice for your application. Level sensors from ifm. - 8

Capacitive. For the detection through non-metallic tank walls. Many functions such as binary switching output, timer functions as output, damping function as well as normally closed / normally open and window function. Process values, parameter setting data and diagnostic information can be transferred and evaluated via IO-Link. Parameter setting via IO-Link before installation, as an alternative also via pushbuttons on the sensor. Simple parameter setting of many sensors via "copy & paste" in the LR DEVICE software or via a memory plug. Ingeniously simple switch point setting thanks to the...

Open the catalog to page 8
The right choice for your application. Level sensors from ifm. - 9

For industrial applications Sensing range [mm] Type KQ point level sensors Capacitive sensors in small plastic rectangular housing. Easy installation with mounting adapters and fixing straps. 12-digit display for optimum switch point setting (KG / KI6000).

Open the catalog to page 9
The right choice for your application. Level sensors from ifm. - 10

Capacitive. For applications on hydraulic and coolant tanks. Type LT for level and temperature monitoring. Professional For industrial applications in water-based or oil-based media. Versions with 2 or 4 switching outputs or analogue output 4...20 mA / 0...10 V. Type LK12 with approval as overflow prevention to WHG*. Variable insertion depths thanks to clamp fitting. Type LK level sensors Display and handling directly on the unit or via IO-Link1). As an option with analogue output or up to four switching outputs. Suitable for oil temperatures up to 70 °C. Versions to...

Open the catalog to page 10
The right choice for your application. Level sensors from ifm. - 11

WHG Type LT level sensors Display and handling directly on the unit or via iO-Linkh. Suitable for water-based and oil-based media. Suitable for oil temperatures up to 70 °C. For level and temperature. 2 switching outputs level 2 switching outputs temperature 2) 1 analogue output, 1 switching output 1 analogue output level 2) 1 switching output temperature 2) 2) level / temperature selectable

Open the catalog to page 11
The right choice for your application. Level sensors from ifm. - 12

Modular sensor concept, flexible in use. Variable: Rods can be cut to size as required. Measuring principle independent of temperature influences. Versions with two or four switching outputs or analogue output 4...20 mA / 0...10 V. Designs with and without display. Type LR level sensors Display and handling on the unit or via IO-Link. As an option with analogue output or up to four switching outputs. Rod lengths of 10...200 cm selectable. Versions to WHG* available. * German Federal Water Act Process connection Process connection 1)only in connection with rod and coaxial pipe, see page 14...

Open the catalog to page 12
The right choice for your application. Level sensors from ifm. - 13

For hygienic areas and viscous media WHG Type LR27 hygienic level sensor Display and handling on the unit or via lO-Link. Medium temperature -40...150 °C. Pressure - resistant up to 40 bar. Rod lengths of 15...200 cm selectable. Process connection For rods and coaxial pipes see pages 14 -15

Open the catalog to page 13
The right choice for your application. Level sensors from ifm. - 14

Continuous level measurement in contact with the medium Level sensors 3/4" NPT Type LR3300 Type LR7300 Type LR8300 Type LR2350 Rods for LR level sensors with 3/4" NPT or G 3/4 male, industrial applications 1)only in connection with rod and coaxial Coaxial pipes for LR level sensors with G 3/4 male, industrial applications Material stainless steel (1.4301 / 304) Process connection

Open the catalog to page 14
The right choice for your application. Level sensors from ifm. - 15

For industrial applications For hygienic areas and viscous media Hygienic level sensor type LR2750 Rods for level sensor LR2750, hygienic Material high-grade stainless steel (1.4404 / 316L) Process connection wide selection > accessories 15

Open the catalog to page 15
The right choice for your application. Level sensors from ifm. - 16

Hydrostatic. For industrial applications on tanks and in free-flowing waterways. Robust: Overload-protected measuring principles with a good long-term stability. Compact: Pressure transmitters without display and with analogue output. Ceramic-capacitive and piezo-resistive measuring cells. Type PA pressure sensors 2-wire pressure transmitters. Ceramic-capacitive measuring cell. Process connection

Open the catalog to page 16

All Ifm electronic catalogs and technical brochures

  1. OGD582

    2 Pages

  2. O1D

    18 Pages

  3. SB series

    2 Pages

Archived catalogs

  1. ifm pumps

    4 Pages

  2. ifm fans

    4 Pages

  3. ifmpressions

    18 Pages

  4. DF1214

    2 Pages

  5. DF2212

    2 Pages

  6. DF1212

    2 Pages

  7. DF1100

    2 Pages