O1D
1 /18Pages

O1D

O1D
1 /18Pages

Catalog excerpts

O1D-1

Release date 2017-09-26 Copyright 2017, Builder: 4.0.1.0, Time: 01:52:55 O1D Vendor ID Device ID Vendor name Vendor text Vendor URL Communication IO-Link revision Bit rate Minimum cycle time SIO mode supported Features Block parametrization Data storage Electronic level sensor, 20...999.5 cm

 Open the catalog to page 1
O1D-2

Process data (Process data input) Name Data type Value range Offset Unit Current level Current object reflectivity Device status Current device status, a copy of the variable [Device Status] in the UIntegerT process data channel (0) Device is OK (1) Maintenance required (2) Out of specification (3) Functional check (4) Failure (false) inactive (true) active (false) inactive (true) active

 Open the catalog to page 2
O1D-3

Process data (Process data input) Name Data type Value range Offset Unit

 Open the catalog to page 3
O1D-4

Variables Name Data type Access rights Value range Offset Unit Standard Command (130) Restore Factory Settings (208) [cEMP] Teach Tank Empty (209) [cMEd] Teach Tank Filled (240) IO-Link 1.1 system test command 240, Event 8DFE appears (241) IO-Link 1.1 system test command 241, Event 8DFE disappears (242) IO-Link 1.1 system test command 242, Event 8DFF appears (243) IO-Link 1.1 system test command 243, Event 8DFF disappears Device Access Locks 12 Data Storage (false) Unlocked (true) Locked Local Parameterization (false) Unlocked (true) Locked Vendor Text Product Name

 Open the catalog to page 4
O1D-5

Variables Name Data type Access rights Laser Sensor Value range Offset Unit Product Text Serial Number Hardware Version Firmware Version Device Status (0) Device is OK (1) Maintenance required (2) Out of specification (3) Functional check (4) Failure 5 to 255 (Reserved) Detailed Device Status 37

 Open the catalog to page 5
O1D-6

Variables Name Switchching signal channel 1, Switch-On delay 370 Access rights Value range Offset Unit Switchching signal channel 2, Switch-Off delay 373 Switchching signal channel 2, Switch-On delay 372 Data type Switchching signal channel 1, Switch-Off delay 371 Mean filter. If activated, measure results will be averaged over the given period. 517 Delay time of outputs after fault 530 [OUT 1] behaviour in case of fault 531 [OUT 2] behaviour in case of fault 532 Power cycles Number of power cycles since delivery 541

 Open the catalog to page 6
O1D-7

Variables Name Operating hours Counter of the operating hours since delivery 542 Data type Access rights Value range Offset Unit

 Open the catalog to page 7
O1D-8

Variables Name Data type Access rights Value range Offset Unit

 Open the catalog to page 8
O1D-9

Variables Name Active Events Bit mask for current pending events 545 Data type Bit_31, Bit 31 indicates the assigned pending event Bit_30, Bit 30 indicates the assigned pending event Bit_20, Bit 20 indicates the assigned pending event Bit_19, Bit 19 indicates the assigned pending event Bit_18, Bit 18 indicates the assigned pending event Bit_17, Bit 17 indicates the assigned pending event Bit_16, Bit 16 indicates the assigned pending event Bit_11, Bit 11 indicates the assigned pending event Bit_10, Bit 10 indicates the assigned pending event Bit_3, Bit 3 indicates the assigned pending event Access...

 Open the catalog to page 9
O1D-10

Variables Name Active Events Bit mask for current pending events 545 Bit 2 indicates the assigned pending event Data type Access rights Value range Offset Unit

 Open the catalog to page 10
O1D-11

Variables Name Data type Access rights Value range Offset Unit

 Open the catalog to page 11
O1D-12

Variables Name Param configuration fault Displays the wrongly set parameters 546 Data type Access rights Value range Offset Unit

 Open the catalog to page 12
O1D-13

Variables Name Data type Access rights Value range Offset Unit [Loc] locks the local user interface to prevent unintentional changes, [Loc] is resettable at the device 550

 Open the catalog to page 13
O1D-14

Variables Name Selection of the physical unit 551 Data type Access rights Value range Offset Unit (3) Hno / Hysteresis fct normally open (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (16) Off / Output Off Switch point 1, [SP1] must be greater than [rP1]. Please take into account the current [rP1] value. [SP1] will be refused if below [rP1]. [SP] = [FH] and [rP] = [FL] if [OU1] = Fno, Fnc 583 Reset point 1, [rP1] must be smaller than [SP1]. Please take into account the current [SP1] value.I[rP1]...

 Open the catalog to page 14
O1D-15

Variables Name Data type Access rights Value range Offset Unit (1) I / Analog signal 4…20 mA (1) I / Analog signal 4…20 mA (2) U / Analog signal 0...10 V (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (16) Off / Output Off Switch point 2, [SP2] must be greater than [rP2]. Please take into account the current [rP2] value. [SP2] will be refused if below [rP2]. [SP] = [FH] and [rP] = [FL] if [OU2] = Fno, Fnc 593 Analogue end point 2. [AEP2] must be greater than [ASP2]. Please take into account...

 Open the catalog to page 15
O1D-16

Variables Name Tank height, distance between tank bottom and sensor. The value is used as reference for the filling level. A teach command can be used to set the value. 1607 Data type Access rights Value range Offset Unit Input of the filling level for teaching of the tank height if the tank is already filled. 1608 Transmitter configuration Configuration transmitter light 2000 (2) OFF_ExtActive / Off by external signal active (0) Off / Off (1) On / On (2) OFF_ExtActive / Off by external signal active (3) On_ExtActive / On by external signal active Setting of the measuring rate 2005 Repeatability....

 Open the catalog to page 16
O1D-17

Events Code Parameter missing Check data sheet Device temperature over-run Clear source of heat Device temperature under-run Insulate device Warning NEAR - Object too close to sensor. Device Status = 2 (Out of specification) Device exceeds datasheet-specification, but stilll works FAR - Object too far from sensor. Warning Device Status = 2 (Out of specification) Device exceeds datasheet-specification, but stilll works Overexposure. Device Status = Warning 2 (Out of specification) Please check your application Underexposure. Device Status = Warning 2 (Out of specification) Please check your application...

 Open the catalog to page 17
O1D-18

Error types Error code Written command is not supported by the device application Function temporarily unavailable Written command is not available due to the current state of the device application Written single parameter collides with other actual parameter settings Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed Read or write service is refused due to a temporarily unavailable application

 Open the catalog to page 18