1. Catalogs
  2. iesy GmbH
  3. Cooling Solutions

Cooling Solutions

Cooling Solutions
1 / 16 PagesView full catalog

Cooling Solutions

Product catalog summary
Introduction
As electronic devices become more compact and powerful, managing heat generation becomes crucial. Congatec's patented cooling concept for COM Express modules addresses this issue, allowing for enhanced performance without overheating.
Challenges of Heat Management
Heat distribution is uneven across circuit boards, with processors and chipsets being the primary heat sources. Traditional cooling methods like underclocking are insufficient for maximizing performance, necessitating new cooling solutions.
Classic Cooling Designs
Traditional COM cooling designs involve layered approaches using copper or aluminum blocks, phase-change materials, and heatspreaders, limited to modules with a maximum power dissipation of 35W due to size constraints.
Limitations and Innovations
Conventional solutions face challenges with high power dissipation due to limited thermal conductivity of gap fillers. Heat pipes, used in laptops, offer a more efficient alternative by utilizing evaporation and condensation cycles for heat transfer.
Congatec's Advanced Cooling Solution
Congatec enhances classic cooling with a modified heat pipe, improving heat transfer from the chip to the heatspreader, eliminating the need for gap fillers, reducing mechanical stress, and increasing cooling efficiency.
Customer-Specific Innovations
The new cooling module supports innovative designs, such as fanless systems with casing cooling fins, applicable to other electronic circuits, providing an effective and cost-efficient cooling solution.
Extended Lifespan and Reliability
The improved cooling solution increases thermal reserves, extending system lifespan and reliability. A temperature reduction of 5 Kelvin can double the statistical lifespan, reducing total costs over a system's lifetime.
Summary
Lab tests indicate a thermal advantage of up to 14°C with Congatec's heat pipe solutions, potentially enhancing the lifetime of COM Express solutions by up to eight times. The flexible cooling solution is suitable for various embedded computer modules, offering scalable performance and power consumption.
Conclusion
Congatec's cooling solution provides rapid spot cooling, eliminates gap fillers, reduces mechanical stress, and extends module lifespan, enabling innovative, customer-specific cooling concepts for new performance dimensions.
Thermal Concept Development
The document discusses thermal concept development using heatspreaders, highlighting configurations like top-mounted and back-mounted heatspreaders, with thermal images showing heat distribution without additional cooling.
Specifications and Calculations
Sample calculations for a CPU and chipset with a combined TDP of 25.3 Watts are provided, setting a maximum surface temperature of 60°C and an environmental temperature of 40°C. The importance of selecting an appropriate cooling unit based on construction height, mechanical orientation, and fan mounting capabilities is outlined.
Thermal Simulation
Thermal simulations predict temperature distribution before prototype construction, considering factors like horizontal construction, free air circulation, and material choice (aluminum). The document emphasizes optimizing cooling device construction using simulation software like Flotherm.
Cooling Solutions for Embedded Modules
The document details cooling solutions for Congatec embedded computer modules, including COM Express, XTX, and ETX standards, highlighting the importance of a defined cooling concept for system design and offering temperature-dependent fan control for certain modules.
Qseven Cooling
The Qseven specification defines a heatspreader as a standardized cooling interface. The document describes the setup of Qseven heatspreaders, including phase change foil, copper blocks, and gap pad materials, and discusses cooling solutions with fins and the importance of airflow.
COM Express Cooling
COM Express modules use different setups based on power consumption, including standard, heat pipe, and flat pipe configurations. The document explains the use of phase change materials, copper blocks, and heat pipes for efficient heat transfer, describing the benefits of patented heat pipe and flat pipe technologies for improved computing performance and longevity.
Mounting and Specifications
The document provides detailed specifications for mounting options, including top and bottom mounting versions with specific standoff measurements, listing various module references, types, technologies, and mounting details for different cooling solutions and heatspreaders.
Overview
The document provides detailed specifications and descriptions of various cooling solutions and heat spreaders for different Congatec products, including COM Express® Type 10, ETX/XTX, and others, outlining the materials, dimensions, and mounting options for each product.
Specifications
The cooling solutions and heat spreaders are categorized by product type, such as conga-TCA, conga-TCA3, conga-TCG, conga-TFS, conga-TS67, conga-TS87, conga-MA3, and others, each described with its reference number, type, technology, mounting options, and specific features like anodization and plating.
Materials and Design
The products are made from materials like orange anodized aluminum and nickel-plated components, including passive and active cooling solutions, with some featuring integrated fans for enhanced cooling efficiency.
Mounting and Installation
The document details the mounting options for each product, specifying top and bottom mounting versions with bore hole and threaded standoffs, describing the use of phase change foil, copper blocks, and gap pad materials to ensure effective heat transfer and mechanical pressure.
Product Compatibility
The cooling solutions and heat spreaders are compatible with various generations of Intel® and AMD processors, including 2nd to 5th Gen Intel® Core™ processors and AMD Embedded processors, with compatibility for different form factors like Mini-ITX, Pico-ITX, and Qseven®.
Additional Information
The document includes contact information for Congatec's headquarters and subsidiaries worldwide, emphasizing the company's global presence, noting that the information is subject to change and advising consulting the Congatec website for the latest updates.
See more

Catalog excerpts

Cooling Solutions-2

Full speed ahead while keeping a cool head: A smart cooling solution for unbridled processor performance Electronics are getting smaller and more and more powerful. As component functionalities and packing densities on the chip and board increase, more heat is produced per unit area. congatec’s patented cooling concept for COM Express modules paves the way for future performance growth. A hot performance Heat is not distributed evenly across a circuit board. Hot spots occur in the vicinity of the processors and chipsets, since these components generate the most heat. For this reason, the processors...

 Open the catalog to page 2
Cooling Solutions-3

Limitations of the conventional solution For the best heat dissipation results, a perfect thermal connection to the cooling system is required. The thermal conductivity of the gap filler material is limited. When power losses are high, the gap filler layer inevitably gets thinner. Thin gap filler layers have lower mechanical tolerances. To compensate for differences in component height more pressure must be applied. The cooling capacity depends to a large degree on the amount of heat-absorbing material used and the heat dispensing surface area. Copper is expensive; large heat sinks are heavy...

 Open the catalog to page 3
Cooling Solutions-4

New cooling module inspires innovative customer ideas congatec’s new cooling solution provides scope for innovative customer ideas. For example, the heat pipe can be designed in such a way that it can be connected to a customer-specific heat sink. Fanless designs are possible, provided the casing is equipped with appropriately sized cooling fins. Ultimately, the design depends on the specific application. The key features of the concept are equally applicable to other electronic circuits. Hot spots also occur in power modules. Semiconductor circuits in rectifiers and inverters, for instance,...

 Open the catalog to page 4
Cooling Solutions-5

Keeping COMs cool Flexible cooling solution for COM Express®, XTX™ and ETX® embedded computer modules. COM Express, XTX and ETX embedded computer modules allow for a fairly easy implementation of customer-specific applications. The specific functions, connectors and components for the necessary peripherals can be conveniently placed on a carrier board developed especially for this purpose. The PC itself is attached as a COM (computer-on-module). The performance of the COM and power consumption are easily scalable. The required cooling system can vary depending on the selected performance class....

 Open the catalog to page 5
Cooling Solutions-6

However, if high performance CPUs are used an additional thermal connection to the heatspreader is definitely required. In most cases the heatspreader and an additional thermal gap pad are attached to a metal casing to offset mechanical tolerance. The metal casing functions as a cooling device. This marked increase in available surface for the purposes of dispensing heat enables even relatively resource-intensive processors to passively maintain appropriate operating temperatures. The heatspreader is also useful at unusually low temperatures. By adding a heating film to the heatspreader, the...

 Open the catalog to page 6
Cooling Solutions-7

The CPU and chipset used for the sample calculation in Figure 7 have a combined TDP of 25.3 Watts. These Thermal Design Power specifications are “worst case” scenarios. Since it uses a heatspreader, the upper limit for the surface temperature of the thermal concept is 60°C. The maximum environmental temperature is set at 40°C. With these details the maximum thermal resistance required by the cooling system can now be determined in order to stay below a heat spreader surface temperature of 60°C: An appropriate type of cooling unit can now be selected. For the purposes of selection, it is important...

 Open the catalog to page 7
Cooling Solutions-8

Qseven Cooling Qseven Cooling The Qseven specification defines a heatspreader as a standardized cooling interface. congatec offers module specific implementations of heatspreaders. Setup of all Qseven heatspreaders and cooling solutions: – Phase change foil reduces to compensate gaps between the dies and the copper block. – Copper block to handle the heat transfer. The copper block is fixed by a central pin in order to allow movements only in the height dimension. – Gap pad material between the copper block and the heatspreader/cooling solution to compensate for the height tolerances and to provide...

 Open the catalog to page 8
Cooling Solutions-9

Qseven cooling solution Qseven heatspreader Qseven heatspreader copper blocks Pin avoids sliding of the copper block Heat Spreader Orange anodized Heat Spreader Orange anodized Cooling Solution Orange anodized Cooling Solution Orange anodized Heat Spreader Orange anodized Heat Spreader Orange anodized Cooling Solution Orange anodized Heat Spreader Orange anodized Heat Spreader Orange anodized Cooling Solution Orange anodized Heat Spreader For Dual/Quad core industrial (lidded FCBGA ) Heat Spreader For Solo/Dual Lite all variants (MAP BGA) Heat Spreader For Dual/Quad core commercial (open FCBGA)...

 Open the catalog to page 9
Cooling Solutions-10

COM Express® Cooling Setup of COM Express heatspreaders and cooling solutions: Standard Standard Heatspreader The COM Express modules with low power consumption use this setup: – Phase change foil compresses to compensate for gaps between the dies and the copper block. – Copper block to handle the heat transfer. This block is fixed with two pins to allow movement only in the height dimensions. – Gap pad material between the copper block and the heatspreader/cooling solution to compensate for the height tolerances and to provide proper mechanical pressure to the dies. Heat Pipe High performance...

 Open the catalog to page 10
Cooling Solutions-11

Heatspreader Heatspreaders are compliant to the COM Express 2.1 specification and are shipped with mounting screws. Heat spreaders need to be conducted to other system cooling parts i.e. metal housing. The heat spreader is delivered with mounting material (screws and washer). The longer screws mount the module to the carrier board. There is one addition, short screw to fix the heat spreader to the module. This allows to generate prepared mounting bundles containing module, memory and heat spreader. Cooling Solutions Cooling solutions have fins and are not intended for conduction cooling. The...

 Open the catalog to page 11

All Iesy GmbH catalogs and technical brochures

  1. conga-TCA5

    3  Pages

  2. conga-TCA3

    3  Pages

  3. conga-TC570

    3  Pages

  4. conga-TC370

    3  Pages

  5. conga-TC170

    3  Pages

  6. conga-MA5

    3  Pages

  7. conga-MA3E

    2  Pages

  8. conga-MA3

    2  Pages

  9. conga-BS77

    3  Pages

  10. conga-BP77

    2  Pages

  11. conga-BAF

    2  Pages

  12. conga-B7XD

    3  Pages

  13. conga-B7E3

    4  Pages

  14. conga-B7AC

    3  Pages

  15. MB115

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.