Overview: The document provides technical specifications and details for the WV4403 and WV5H25 wind vane sensors, including their applications, electrical features, and accessories. These sensors are designed for industrial use, offering a 4-20mA analogue output based on wind direction.
Specifications:
  • WV4403: Operates with a power supply of 12-30 Vdc, maximum current of 20 mA, and provides a 4-20mA analogue output. It is resistant to radio frequency and electromagnetic interference.
  • WV5H25 (Heated): Requires a power supply of 15-24 Vdc, with a heater that operates below 6ºC. It consumes less than 0.5 W above 6ºC and less than 17 W below 6ºC. Maximum current is 1.2 A at 15 V and 1.8 A at 24 V.
General Features:
  • Material: PA+FV / Aluminium with stainless steel bearings.
  • Weight: 170 g for WV4403 and 200 g for WV5H25.
  • Dimensions: 129x190 mm.
  • Operating temperature: -20ºC to +60ºC, storage temperature: -35ºC to +80ºC.
  • Protection: IP65.
Applications: Suitable for use in irrigation control systems, greenhouse automation, solar trackers, ski resort ropeways, cranes, wind turbines, and weather stations. The WV5H25 is specifically designed for sub-zero temperature applications.
Accessories:
  • Stainless steel brackets and hardware for mounting.
  • Magnets for flat ferromagnetic surfaces, supporting up to 90 kg.
  • Steel clamps for irregular parts up to 63 x 45 mm.
Connection Details: The document provides pin configurations for connecting the sensors, including details for the M12 connector and wire color references.
Operating Instructions: The vane must be oriented north for accurate readings, with a survival wind speed of up to 200 km/h. The heater automatically switches off above 6ºC to conserve energy.
See more

Catalog excerpts

WV4403_y_WV5H25_EN-1

TECHNICAL FEATURES WV4403 4-20 mA Electrical features References Power supply Maximum current Output Maximum loop impedance WV5h25 4-20 mA Electrical features Power supply Consumption with heater ta >6°C ( +-3°C) Average consumption with heater ta <6°C ( +-3°C) Maximum current Maximum loop impedance Accessories Measurements Range Starting speed 0103010505 Stainless steel bracket AISI 304 01030105061 Stainless steel bracket plus hardware for mounting the wind sensor on the backet Survival speed 01030105071 Magnets for flat ferromagnetic surfaces. This fixation system can support up to 90 kg 0103010508 2 steel clamps kit that can be fixed to irregular 110 unit minimum order. On sale exclusively with wind sensor. General Features QO j.__electronics Electronics at the service of industry Material PA+FV / Aluminium Bearings Stainless steel X65Cr13 *For other references, please contact us. Weight (with no cable) 170 g WV4403 4-20mA Operating temperature (ice free) -20°C +60°C EMC EN 61000-6-2:2001 WIND VANE WV4403 4-20mA WV5H25 4-20mA (HEATED) WV4403 range of IED Electronics. Wind direction sensor designed for different industries and sectors. IED Electronics Solutions S.L. Pol. Plazaola E 6, 31195 Aizoain. Navarra (Spain) www.iedelectronics.com [email protected] CA-01030107 (04/01/2018) All dimensions and sizes are approximate. Specifications and prices are subject to change without notice. WV4403 detects the vane position by using magnetic sensors avoiding wear and tear. It generates a 4-20mA analogue output, depending on the wind direction. The heated version works from -20 °C. When the temperature is higher than +6° C, the heater switches itself off automatically to reduce the consumption. High resistance to radio frequency interference (RFI) and electromagnetic interference (EMI) 4-20mA passive analogue output Magnetic measuring principle, with no wear and tear or dead zones Stainless steel bearings

 Open the catalog to page 1
WV4403_y_WV5H25_EN-2

APPLICATIONS WIND SPEED - OUTPUT RATIO TABLE ORIENTATION VANE WV4403 has been designed to be used in industrial applications. Connected to devices such as dataloggers, PLCs, analogue signal displays (see our references WM44-EVO11, V10, V12, BS100/3 4-20mA), it measures the wind direction and/or activates predefined alarm values. Application examples: Irrigation control system, automation in greenhouses, solar trackers, ropeways at ski resorts, cranes, wind turbines, weather stations etc. All those applications that contribute to a greater control and greater security. Besides, WV5H25 has been...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.