Product catalog summary
Overview: The WM44 V3 is a wind speed measurement device that displays readings in km/h, MPH, or m/s. It supports 2 and 3 wire sensors and provides a 10-20 Vdc power output. The device is equipped with a wind speed display and two alarms, and it is pre-configured to work with the Anemo4403 V3 sensor.
Technical Features:
  • Electrical Features: Operates on a 230 Vac power supply with a consumption of less than 3.5 VA. It accepts square, triangular, or sinusoidal input signals ranging from 1-750 Hz and 5-35 Vdc or 4-24 Vac.
  • Inputs: Compatible with Anemo4403 V3 sensor, Namur, and direct signal inputs. Input impedance varies based on connection type.
  • Outputs: Provides a power output for sensors at 10 Vdc or 20 Vdc. Analogue outputs are available in 4-20 mA or 0-10 Vdc for panel versions.
  • General Features: The device dimensions vary by model, with a weight of 350 g for WM44-P V3 and 450 g for WM44-DRM V3. It operates within a temperature range of -20 ºC to +70 ºC and has IP protection ratings of IP50 and IP20 respectively.
Alarms: The device features configurable alarms that activate when wind speed exceeds set values. ALARM2 deactivates ALARM1 upon activation, and the display blinks to indicate danger. Alarms can be set to continuous or intermittent modes with configurable delays.
Programming: The device allows for user-defined settings and records minimum and maximum wind speeds. Programming involves various steps (P00-P20) to configure units, reference speeds, alarm settings, and analogue outputs.
Installation and Connections: The device supports panel and DIN rail mounting. It requires careful connection of sensors and inputs, with specific instructions for Namur type sensors and open-collector NPN sensors.
Notes: Factory default settings comply with ITC MIE-AEM-2 standards, and users can reprogram the device to meet local safety regulations.
See more

Catalog excerpts

WM44-P V3 / WM44-DRM V3.-1

REFERENCES AND ACCESSORIES Electrical features References Power supply 230 Vac, 50-60 Hz (see Inputs Type of input signal Square, triangular or sinusoidal 1-750 Hz / 5-35 Vdc o 4-24 Vac Input impedance -For connection with Anemo4403 or Namur: 1000 ohm -Direct: 10 k ohm Sensors admitted Anemo4403 V3 sensor -3 wire sensor -Namur -Direct signal (see “type of input signal) QO Led electronics Electronics at the service of industry Other devices of WM44 V3 range Power output for sensors 10 Vdc or 20Vdc +/- 10% 0,5 W (only for panel version) Max. connectable impedance 500 Ohm (4-20mA analogue output) Analogue output resolution 1000 dots Analogue output accuracy 1,5% Compatible anemometers and wind vanes 0103010801 ANEMO4403 V3 PULSES OUTPUT M8 LATERAL General features 0103010802 ANEMO4403 V3 PULSES OUTPUT M8 UNDERSIDE Dimensions See drawings 0103011301 ANEMO5H25 V3 PULSES OUTPUT M12 UNDERSIDE NO FEMALE CONNECTOR Measurements Accuracy (100Hz=100km/h) +/- 1km/h Maximum measurable speed 999 km/h, 999MPH, 99.9 m/s *For other references, please contact us. IED Electronics Solutions S.L. Pol. Plazaola E 6, 31195 Aizoain. Navarra (Spain) www.iedelectronics.com [email protected] CA-01060305/8 (07/09/2017) All dimensions and sizes are approximate. Specifications and prices are subject to change without notice. WM44 V3 have a 3-digit wind speed reading in km/h, MPH or m/s. Choosing one of the 3 options is possible at any time by pressing “SELECT”. They admit 2 and 3 wire sensors and have a 10-20 Vdc power output. Wind speed display with 2 alarms Pre-configured to work with Anemo4403 V3 pulses output sensor Adjustable pre-alarm and alarm 4-20mA or 0-10V analogue output upon request

 Open the catalog to page 1
WM44-P V3 / WM44-DRM V3.-2

PROGRAM STEPS Alarms The alarm is triggered when the wind speed reaches or exceeds the programmed value. It includes a configurable delay to prevent the alarm from being triggered by gusts of winds. The alarm is deactivated when the wind speed drops below the programmed value. It also has a configurable delay to prevent the alarm from being deactivated by temporary periods of low-intensity wind. The activation of ALARM2 deactivates ALARM1. When ALARM2 is activated, the reading will blink to warn about the danger. Alarms configuration: Trigger values, polarity, intermittent or continuous alarm,...

 Open the catalog to page 2