TECHNICAL FEATURES Electrical features Inputs Type of input signal Square, triangular or sinusoidal 1-750 Hz / 5-35 Vdc o 4-24 Vac Input impedance -For connection with Anemo4403 or Namur: 1000 ohm -Direct: 10 k ohm Sensors admitted Anemo4403 V3 sensor -3 wire sensor -Namur -Direct signal (see “type of input signal) QDi__electronics Electronics at the service of industry Assembling on DIN 46 277 and DIN EN 50 022 0106030701 WM44-DRM V3 230Vac Other devices of WM44 V3 range Power output for sensors 10 Vdc or 20Vdc +/- 10% 0,5 W (only for panel version) Max. connectable impedance 500 Ohm (4-20mA analogue output) Analogue output resolution 1000 dots Analogue output accuracy 1,5% Compatible anemometers and wind vanes General features Dimensions See drawings Maximum measurable speed 999 km/h, 999MPH, 99.9 m/s *For other references, please contact us. WM44-P V3 / WM44-DRM V3 WM44 V3 range of IED Electronics. Anemometer display with alarms. QO___ electronics IED Electronics Solutions S.L. Pol. Plazaola E 6, 31195 Aizoain. Navarra (Spain) www.iedelectronics.com [email protected] All dimensions and sizes are approximate. Specifications and prices are subject to change without notice. WM44 V3 have a 3-digit wind speed reading in km/h, MPH or m/s. Choosing one of the 3 options is possible at any time by pressing “SELECT”. They admit 2 and 3 wire sensors and have a 10-20 Vdc power output. Wind speed display with 2 alarms Pre-configured to work with Anemo4403 V3 pulses output sensor Adjustable pre-alarm and alarm 4-20mA or 0-10V analogue output upon request

 Open the catalog to page 1
WM44_EN-2

PROGRAM STEPS Alarms The alarm is triggered when the wind speed reaches or exceeds the programmed value. It includes a configurable delay to prevent the alarm from being triggered by gusts of winds. The alarm is deactivated when the wind speed drops below the programmed value. It also has a configurable delay to prevent the alarm from being deactivated by temporary periods of low-intensity wind. The activation of ALARM2 deactivates ALARM1. When ALARM2 is activated, the reading will blink to warn about the danger. Alarms configuration: Trigger values, polarity, intermittent or continuous alarm,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.