SPC: Coded Non Contact IDECODE - 1

SECTION 10 CODED NON CONTACT SAFETY INTERLOCK SWITCHES IDECODE - Coded Non Contact Type: SPC FEATURES: Universal fitting - established 22mm footprint suitable for most applications Coded Magnetic Actuation Withstands environments where high humidity or hose down is required Switching Tolerance up to 14mm High specification and durable polyester housing Will operate with most Safety Relays Wide 14mm sensing with high tolerance to misalignment Up to: PLe ISO13849-1 2NC 1NO circuits - high switching life - no moving parts Quick Connect versions available Quick Connect M12 versions fitted with 250mm (10”) cable CONNECTION EXAMPLE: CODED SWITCH Single switch connected to an SCR-21-i or SCR-31-i to give Dual Channel monitoring with monitored Manual Start Female QC Lead Female QC Lead Standards: ISO14119 EN60947-5-1 EN60204-1 ISO13849-1 EN62061 UL508 Safety Classification and Reliability Data: ISO13849-1 Up to PLe Category 4 EN62061 Up to SIL3 PFHd 8.71 x 10-11 Proof Test Interval (Life) 20 years MTTFd 866 years Safety Channel 1 NC 24Vdc 0.2A Max. Rating Safety Channel 2 NC 24Vdc 0.2A Max. Rating Safety Channel 3 NO 24Vdc 0.2A Max. Rating Minimum Switched Current 10Vdc 1mA Dielectric Withstand 250Vac Insulation Resistance 100 Mohms Recommended Setting Gap 5mm Switching Distance Sao 10mm Close (Target to Target) Sar 20mm Open Tolerance to Misalignment 5mm in any direction from 5mm setting gap Switching Frequency 1.0Hz maximum Approach Speed 200mm/min to 1000mm/sec Body Material UL approved polyester Operating Temperature -25C +80C Enclosure Protection IP69K IP67 Shock Resistance IEC68-2-27 11ms 30g Vibration Resistance IEC68-2-6 10-55Hz 1mm Cable Type PVC 6 or 8 core 6mm OD Conductors 0.25mm2 Mounting Bolts 2xM4 Tightening torque 1.0Nm Mounting Position Any For all IDEM switches the normally closed (NC) circuits are closed when the guard is closed and the actuator is present. Quick Connect QC M12 8 Way Male Plug Pin view from Switch 8 5 4 6 7 Flying Lead Colour Orange Brown Yellow Green Black TYPE Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Idecode SPC Circuit Output Types (Actuator Solid State Present) Auxiliary NO or NC 200mA Max. 24Vdc Auxiliary NO or NC Safety NC2 +ve 200mA Max. 24Vdc Safety NC2 -ve Safety NC1 +ve 200mA Max. 24Vdc Safety NC1 -ve Supply +24Vdc Supply 0Vdc Note: 2NC 1NO versions have 2NC Safety and 1NO Auxiliary Circuits 3NC versions have 2NC Safety and 1NC Auxiliary Circuits AVAILABLE WITHOUT LED IF REQUIRED.

Open the catalog to page 1

All Idem Safety Switches catalogs and technical brochures

  1. SCR-7

    4 Pages

  2. KLM-Z-4ST

    2 Pages

  3. GLS-SS

    1 Pages

  4. RPC

    1 Pages

  5. INCH-3

    1 Pages

Archived catalogs