SECTION 10 CODED NON CONTACT SAFETY INTERLOCK SWITCHES www.idemsafety.com 92 KOBRACODE - Coded Non Contact Type: KPC FEATURES: Industry housing shape 52mm wide 98mm long 40mm fixing 2NC 1NO semi conductor outputs for connection to safety relay Visual LED indication of switch status Fully encapsulated sealing and pre-wired 2m, 5m or 10m cable Wide 10mm sensing with high tolerance to misalignment M12 8 Way Quick Connect version available (flying lead 150mm) Coded Magnetic Actuation Switching Tolerance up to 10mm Will operate with most Safety Relays APPLICATION: IDEM KPC Coded Non Contact switches have been designed to interlock hinged, sliding or removable guard doors. They have an industry standard fixing and are specifically advantageous where: (a) severe guard alignment exists using traditional tongue type versions (b) long mechanical life is required (no moving or touching parts) When used in combination with Dual Channel Safety Relays they can be used to provide up to PLe ISO13849-1 SIL3 EN62061 Cat4 EN954-1 SENSING PRINCIPLE: Standards: ISO14119 EN60947-5-1 EN60204-1 ISO13849-1 EN62061 UL508 Safety Classification and Reliability Data: ISO13849-1 Up to PLe Category 4 EN62061 Up to SIL3 PFHd 8.71 x 10-11 Proof Test Interval (Life) 20 years MTTFd 866 years Safety Channel 1 NC 24Vdc 0.2A Max. Rating Safety Channel 2 NC 24Vdc 0.2A Max. Rating Safety Channel 3 NO 24Vdc 0.2A Max. Rating Minimum Switched Current 10Vdc 1mA Dielectric Withstand 250Vac Insulation Resistance 100 Mohms Recommended Setting Gap 5mm Switching Distance Sao 8mm Close (Target to Target) Sar 20mm Open Tolerance to Misalignment 5mm in any direction from 5mm setting gap Switching Frequency 1.0Hz maximum Approach Speed 200mm/min to 1000mm/sec Body Material UL approved polyester Operating Temperature -25C +80C Enclosure Protection IP67 (NEMA 6) Shock Resistance IEC68-2-27 11ms 30g Vibration Resistance IEC68-2-6 10-55Hz 1mm Cable Type PVC 8 core 6mm OD Conductors 0.25mm2 Mounting Bolts 2xM5 Tightening torque 1.0Nm Mounting Position Any For all IDEM switches the normally closed (NC) circuits are closed when the guard is closed and the actuator is present. CONDUIT OR CABLE EXIT Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Kobracode KPC Pre-wired 2m End Pre-wired 5m End Pre-wired 10m End Pre-wired 2m Left Pre-wired 5m Left Pre-wired 10m Left Pre-wired 2m Right Pre-wired 5m Right Pre-wired 10m Right QC M12 8 Way 150mm End
Open the catalog to page 12 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
4 Pages
152 Pages
56 Pages