1. Catalogs
  2. IDEC
  3. Complete Communications & Networking Catalog
video corpo
cad

Complete Communications & Networking Catalog

Complete Communications & Networking Catalog
1 / 76 PagesView full catalog

Complete Communications & Networking Catalog

Product catalog summary
Automation & Sensing
This section discusses automation and sensing products, focusing on AS-Interface systems that simplify wiring and reduce costs. Key components include the MicroSmart AS-Interface Master Module, SX5A AS-Interface Communication Terminal, and SwitchNet Control Units, which support flexible network topologies and offer space and wire savings.
Safety
This section highlights emergency stop switches and safety communication terminals, compliant with international safety standards like IEC 61508 SIL3 and EN954-1 safety category 4. Integrating safety functions into AS-Interface systems provides a compact solution for safety equipment.
Switching & Controls
Details various control units and pilot lights with AS-Interface communication chips. The HW and L6 series offer models with features like spring clamp terminals for reduced wiring time and adjustable illumination levels.
Cost and Efficiency
Emphasizes cost-saving benefits of AS-Interface and SwitchNet wiring systems over conventional wiring, reducing labor and material costs by simplifying the wiring process and minimizing control panel space.
Product Specifications
Provides detailed specifications for products like power supplies, communication terminals, and PLC modules, emphasizing compliance with AS-Interface Ver. 2.1 and other standards for compatibility and reliability.
Additional Resources
Mentions online resources such as product information, software demos, part configuration tools, and downloadable manuals to support product selection and implementation.
General Specifications
The AS-Interface Master Module operates between 0 to 55°C, with storage temperatures from -25 to +70°C, and requires a non-condensing relative humidity of 30 to 90%. It is protected to IP20 standards and suitable for non-corrosive atmospheres, operating at altitudes up to 2000m.
Functional Specifications
Requires an external AS-Interface power supply of 29.5 to 31.6V DC, with a normal operation current of 65mA and a maximum of 110mA. Features a durable connector with a minimum insertion/removal durability of 100 times.
Communication Specifications
Supports a maximum bus cycle of 3ms for 1-19 slaves and up to 10ms for 62 slaves, connecting up to 31 standard slaves or 62 A/B slaves, with a maximum of 248 I/O points for standard slaves and 434 for A/B slaves.
Installation Guidelines
MicroSmart modules should be installed in a cabinet with pollution degree 2 environments, maintaining an operating temperature between 0ºC and 55ºC with adequate ventilation.
Power Supply Specifications
The PS2R AS-Interface Power Supply accepts 100 to 240V AC input and provides 30.5V DC output, featuring overcurrent, overvoltage, and undervoltage protection.
Communication Terminals and Repeaters
The SX5A AS-Interface Communication Terminals are compliant with AS-Interface Ver. 2.1, connecting up to 62 slaves and featuring overload detection functions. The repeater extends the network up to 300m.
Specifications Overview
Outlines specifications for SX5A AS-Interface modules, including compliance with protection class 3 VDE0106 / IEC60364-4-41, with operating temperatures from -25 to +60°C and storage temperatures up to +85°C.
Input and Output Specifications
Supports 2- and 3-wire sensors (NPN and PNP), with load current capacities specified for different temperature conditions. Outputs include PNP transistor outputs with overload and short-circuit protection.
Communication and Networking
Supports standard slave and A/B slave types, with specific profiles and data bits for input and output. Communication errors result in outputs turning off.
LED Indicators and Error Indications
LED indicators provide status updates for power, auxiliary power, input, output, and fault conditions.
Repeater Specifications
The SX5A-RP1 repeater extends the AS-Interface network up to 300 meters, with IP65 protection and easy connection via insulation displacement technology.
Address Assignment Procedures
Provides instructions for address assignment using a hand-held programming device and SwitchNet addressing port adapter.
Hand-held Programming Device
The SX9Z-ADR1N model is used for slave address assignment and data read/write operations.
SwitchNet HW Series Control Units
Covers the SwitchNet HW Series control units, compliant with AS-Interface Ver. 2.1, featuring spring clamp terminals and various models with IP65 protection.
Overview
Provides specifications and part numbers for the SwitchNet HW Series, focusing on pushbuttons, selector switches, key switches, and accessories.
Pushbuttons
Lists different styles of pushbuttons, including round flush, round extended, mushroom, and square flush, with specific part numbers for each configuration.
Pilot Lights
Pilot lights are available in round flush and square flush styles, with lens color codes and specific part numbers.
Selector and Key Switches
Available in knob and key styles, with 2-position and 3-position options, and specific part numbers for each configuration.
Accessories
Lists various accessories, including T-branch connectors, programming devices, and locking ring wrenches, with specific part numbers.
Specifications
Outlines general specifications such as operating voltage, input current, dielectric strength, insulation resistance, and operating temperature.
Mechanical and Electrical Specifications
Details terminal style, applicable wire sizes, mounting hole size, and mechanical life expectancy for different operations.
Digital I/O Data Allocation
Provides a table for digital I/O data allocation, detailing input and output data for various slave units.
Write_Parameter Command
Instructions for controlling LED illumination brightness using the Write_Parameter command.
Specifications
The SwitchNet L6 Series operates at a voltage range of 26.5 to 31.6V DC, with a maximum input current of 16mA for pushbuttons and 22mA for illuminated components.
Communication Specifications
Uses AS-Interface Ver. 2.1 standard with a master/slave control system, supporting up to 62 A/B slaves or 31 standard slaves.
Mechanical/Electrical Specifications
Terminal style is a spring clamp, suitable for parallel 2-wire cables, with a mechanical life of momentary switches at least 2,000,000 operations.
Digital I/O Data Allocation
Details input and output data allocation for various components like pushbuttons, pilot lights, and selectors.
Dimensions and Installation
Provides detailed dimensions for components and instructions for panel mounting.
Replacement and Maintenance
Instructions for replacing lenses, marking plates, and LED lamps.
Precautions for AS-interface Wiring
Key precautions include avoiding parallel runs with power lines and confirming correct wiring before powering on.
General Specifications
Outlines specifications for the XA, XW, and FB series of operator interfaces and safety communication terminals.
Mechanical/Electrical Specifications
Details operating force required for different series, with pushlock and pull reset forces specified.
Communication Specifications
Uses AS-Interface Ver. 3.0, with a maximum network length of 100m and up to 31 safety slaves.
Safety Communication Terminal/Safety Monitor
Describes the safety communication terminal and monitor, compliant with EN954-1 category 4.
AS-Interface Safety Monitor Specifications
Electrical specifications include a voltage of 24V DC ±15% and a current of 200 mA.
LONWORKS® I/O Modules
Designed for building automation, offering digital and analog input/output capabilities.
Overview
Provides technical specifications and installation guidelines for various IDEC LONWORKS® I/O modules.
Specifications
  • Voltage and Power: Modules operate at 24V DC or 24V AC with a voltage range of 21.6 to 26.4V.
  • Environmental Conditions: Operating temperature ranges from 0 to 55°C.
  • Physical Characteristics: Designed for DIN rail or direct panel mounting.
Communication Specifications
  • System: Utilizes the LON® system with FTT-10A transceivers.
  • Transmission: Speed is 78 kbps.
  • Network Variables: Uses input and output network variables for data exchange.
Installation Features
  • Spring-up Terminals: Simplifies installation with spring-loaded screws.
  • Removable Terminal Blocks: Allows for easy wiring.
  • Keyed Terminal Blocks: Prevents incorrect insertion.
System Setup Examples
  • Bus Topology: Nodes connect to a single trunk line.
  • Free Topology: Supports star, loop, and bus configurations.
Digital Input/Output Modules
  • Digital Input Module (SX5L-SBN16B1): Supports 16 digital inputs.
  • Digital Output Modules (SX5L-SBT16K1/SX5L-SBT16S1): Provides 16 transistor outputs.
  • Digital I/O Modules (SX5L-SBM16K1, -SBM16K2, -SBM16S1, -SBM16S2): Combines 8 digital inputs and 8 transistor outputs.
Overview
Provides technical specifications and configurations for various LONWORKS® I/O modules.
Transistor Output Specifications
Outlines specifications for models SX5L-SBM16K1/K2 (NPN) and SX5L-SBM16S1/S2 (PNP).
Analog Input Module (SX5L-SBAN041)
Supports 4 analog input channels, suitable for HVAC applications.
Analog Output Module (SX5L-SBAT04X1)
Designed for transmitting analog signals, includes 4 output channels.
Pt100Ω Input Modules (SX5L-SBPT04X1/Y1)
Used for temperature control applications with 4 input channels.
Pulse Input Module (SX5L-SBCN081)
Features 8 input terminals for counting pulse inputs.
Wiring Diagrams and Internal Circuits
Includes detailed wiring diagrams for each module type.
Specifications
Outlines specifications for the SX5L series smart I/O modules.
Wiring and Circuitry
Provides detailed wiring diagrams for both negative and positive common wiring configurations.
Remote-Control Relay Control
Supports 8 output channels for controlling remote relays.
Safety Precautions
Emphasizes turning off power before installation or maintenance.
Installation and Mounting
Instructions for installing and mounting the SX5L modules on panels or DIN rails.
Input/Output Requirements
Specifies operating voltage, leakage current, residual voltage, and ON output current requirements for DC two-wire sensors.
Response Time and Network Requirements
Notes the necessity of terminators for LonWorks networks.
General Information
Includes general information about the SX5L series, emphasizing the importance of following installation and wiring instructions.
See more

All IDEC catalogs and technical brochures

  1. PRODUCT GUIDE

    44  Pages

  2. HR6S

    32  Pages

  3. KW2D SERIES

    16  Pages

  4. Katalog FL1E

    16  Pages

  5. FT1A SmartAXIS

    36  Pages

  6. RV8H-Baureihe

    6  Pages

  7. E-Stop Switches

    16  Pages

  8. XA series

    7  Pages

  9. HG1X

    3  Pages

  10. FL1E

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.