Overview: The Self-Priming Adaptor (SPA) is a low-pressure tank designed to separate air from the liquid being pumped, facilitating fast self-priming of the inlet vacuum hose to the centrifugal pump. It is constructed from 304 stainless steel, with a volume of 8.7 liters and a maximum pressure of 3 Bar.
Specifications: Two models are available, differing in port specifications: 1530-0024S with NPT ports and 1530-0025S with BSPP ports. Both models share the same material and volume specifications.
Safety Precautions: The manual emphasizes not using the pump with flammable or explosive fluids and warns against operating in explosive atmospheres. It highlights the importance of adhering to maximum pressure and temperature limits, ensuring secure connections, and wearing hearing protection due to potential high sound levels.
Installation Guidelines: The SPA should be mounted securely, with specific height and distance requirements for optimal operation. The plumbing system should prevent over-pressurization, and the use of clear hoses is recommended for monitoring purposes.
Operation and Maintenance: The SPA facilitates pump priming by allowing air to escape through a vent line while returning liquid to the pump inlet. Proper valve operation is crucial for effective priming. Regular inspection and maintenance are advised to ensure system integrity.
Troubleshooting: Common issues such as failure to prime, surging, and vacuum loss are addressed with corrective actions like adjusting liquid levels, checking valve positions, and modifying pump speed.
Performance: Priming rates depend on system configuration, with a total lift capacity of 7.6 meters. The system can develop significant pressure against restrictions during priming.
Warranty and Service: Hypro offers a one-year warranty against defects under normal use, excluding certain conditions like excessive speeds or incompatible fluids. Detailed return procedures are provided for warranty claims, emphasizing the need for proper chemical handling and documentation.
See more

All Hypro Pressure Cleaning catalogs and technical brochures

  1. PRODUCT CATALOG

    236  Pages

  2. Gear Driven

    3  Pages

  3. 9302 Series

    2  Pages

Archived catalogs

  1. 2535S OIPM

    12  Pages

  2. Cleanload OIPM

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.