Catalog excerpts

 410N-EH 12 Volt Roller Operation, Installation & Parts Manual-2

-2- The following attention notices are used to notify andadvise the user of this product of procedures that may be dangerous to the user or result in damage to the product. Notes are used to notify of installation, operation, ormaintenance information that is important but not safety related.Caution is used to indicate the presence of a haz-ard, which will or can cause minor injury or property damage if the notice is ignored.Warning denotes that a potential hazard exists andindicates procedures that must be followed exactly to either eliminate or reduce the hazard, and to avoid serious personal...

 Open the catalog to page 2
 410N-EH 12 Volt Roller Operation, Installation & Parts Manual-3

STRAINER See Figure 1 for recommended plumbing installation. Astrainer should be installed on the inlet side of the pump. INLET LINE Check the strainer periodically to ensure that it isnot clogged with debris.DISCHARGE HOSE AND FITTINGS Use a 3/4'' 2-braid suction hose or 3/4'' pipe to prevent collapsing. Avoid all unnecessary bends, elbows, or kinks in the inlet line. The less restrictions in the inlet line, the better the pump will perform. Avoid loops in the inlet line. Loops in the inlet line will permit air to be trapped in the line, preventing the pump from priming. Make sure all connections...

 Open the catalog to page 3
 410N-EH 12 Volt Roller Operation, Installation & Parts Manual-5

Liquid fertilizers also have a tendency to causegumming if left in the pump. Thoroughly flush the pump after each use as described in Care of the Pump. > Popular uses for the 4101N-AE2H include starter fertil-izer application for row crop planting. Starter fertilizer is heavier than water per gallon (approx. 1.40 specific Gravity) and is also more viscous. These two charac- teristics will affect the performance as compared to water like herbicide/pesticide applications. Refer to the Performance Chart on page 6 for examples of perform- ance using 10-34-0 fertilizer. > Before starting the pump,...

 Open the catalog to page 5
 410N-EH 12 Volt Roller Operation, Installation & Parts Manual-8

Hypro warrants to the original purchaser of its products (the PurchaserӔ) that such products will be free from defects in materialand workmanship under normal use for the period of one (1) year for all products except: oil crankcase plunger pumps will be free from defects in material and workmanship under normal use for the period of five (5) years, and accessories will be free from defects in material and workmanship under normal use for the period of ninety (90) days. In addition, Hypro warrants to thepurchaser all forged brass pump manifolds will be free from defects in material and workmanship...

 Open the catalog to page 8

All Hypro Pressure Cleaning catalogs and technical brochures

  1. PRODUCT CATALOG

    236  Pages

  2. Gear Driven

    3  Pages

  3. 9302 Series

    2  Pages

Archived catalogs

  1. 2535S OIPM

    12  Pages

  2. Cleanload OIPM

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.